Cargando…

Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface: A phantom study

BACKGROUND: To quantify image quality and radiation doses in regions adjacent to and distant from bismuth shields in computed tomography (CT). METHODS: An American College of Radiology accreditation phantom with four solid rods embedded in a water-like background was scanned to verify CT number (CTN...

Descripción completa

Detalles Bibliográficos
Autores principales: Liao, Ying-Lan, Lai, Nan-Ku, Tyan, Yeu-Sheng, Tsai, Hui-Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Chang Gung University 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6888723/
https://www.ncbi.nlm.nih.gov/pubmed/31783995
http://dx.doi.org/10.1016/j.bj.2019.04.004
_version_ 1783475296068960256
author Liao, Ying-Lan
Lai, Nan-Ku
Tyan, Yeu-Sheng
Tsai, Hui-Yu
author_facet Liao, Ying-Lan
Lai, Nan-Ku
Tyan, Yeu-Sheng
Tsai, Hui-Yu
author_sort Liao, Ying-Lan
collection PubMed
description BACKGROUND: To quantify image quality and radiation doses in regions adjacent to and distant from bismuth shields in computed tomography (CT). METHODS: An American College of Radiology accreditation phantom with four solid rods embedded in a water-like background was scanned to verify CT number (CTN) accuracy when using bismuth shields. CTNs, image noise, and contrast-to-noise ratios (CNRs) were determined in the phantom at 80–140 kVp. Image quality was investigated on image portions in the zones adjacent (A zone) to and distant (D zone) from a bismuth shield. Surface radiation doses were measured using thermoluminescent dosimeters. Streak artefacts were graded on a 3-point-scale. RESULTS: Changes in CTN caused by a bismuth shield resulted in changes in X-ray spectra. CTN changes were more apparent in the A zone than in the D zone, particularly for a low tube voltage. The degrees of CTN changes and image noise were proportional to the thickness of the bismuth shields. A 1-ply bismuth shield reduced surface radiation doses by 7.2%–15.5%. The overall CNRs were slightly degraded, and streak artefacts were acceptable. CONCLUSIONS: Using a bismuth shield could result in significant CTN changes and perceivable artefacts, particularly for a superficial organ close to the shield, and is not recommended for quantification CT examinations or follow-up CT examinations.
format Online
Article
Text
id pubmed-6888723
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Chang Gung University
record_format MEDLINE/PubMed
spelling pubmed-68887232019-12-12 Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface: A phantom study Liao, Ying-Lan Lai, Nan-Ku Tyan, Yeu-Sheng Tsai, Hui-Yu Biomed J Original article BACKGROUND: To quantify image quality and radiation doses in regions adjacent to and distant from bismuth shields in computed tomography (CT). METHODS: An American College of Radiology accreditation phantom with four solid rods embedded in a water-like background was scanned to verify CT number (CTN) accuracy when using bismuth shields. CTNs, image noise, and contrast-to-noise ratios (CNRs) were determined in the phantom at 80–140 kVp. Image quality was investigated on image portions in the zones adjacent (A zone) to and distant (D zone) from a bismuth shield. Surface radiation doses were measured using thermoluminescent dosimeters. Streak artefacts were graded on a 3-point-scale. RESULTS: Changes in CTN caused by a bismuth shield resulted in changes in X-ray spectra. CTN changes were more apparent in the A zone than in the D zone, particularly for a low tube voltage. The degrees of CTN changes and image noise were proportional to the thickness of the bismuth shields. A 1-ply bismuth shield reduced surface radiation doses by 7.2%–15.5%. The overall CNRs were slightly degraded, and streak artefacts were acceptable. CONCLUSIONS: Using a bismuth shield could result in significant CTN changes and perceivable artefacts, particularly for a superficial organ close to the shield, and is not recommended for quantification CT examinations or follow-up CT examinations. Chang Gung University 2019-10 2019-11-04 /pmc/articles/PMC6888723/ /pubmed/31783995 http://dx.doi.org/10.1016/j.bj.2019.04.004 Text en © 2019 Chang Gung University. Publishing services by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original article
Liao, Ying-Lan
Lai, Nan-Ku
Tyan, Yeu-Sheng
Tsai, Hui-Yu
Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface: A phantom study
title Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface: A phantom study
title_full Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface: A phantom study
title_fullStr Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface: A phantom study
title_full_unstemmed Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface: A phantom study
title_short Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface: A phantom study
title_sort bismuth shield affecting ct image quality and radiation dose in adjacent and distant zones relative to shielding surface: a phantom study
topic Original article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6888723/
https://www.ncbi.nlm.nih.gov/pubmed/31783995
http://dx.doi.org/10.1016/j.bj.2019.04.004
work_keys_str_mv AT liaoyinglan bismuthshieldaffectingctimagequalityandradiationdoseinadjacentanddistantzonesrelativetoshieldingsurfaceaphantomstudy
AT lainanku bismuthshieldaffectingctimagequalityandradiationdoseinadjacentanddistantzonesrelativetoshieldingsurfaceaphantomstudy
AT tyanyeusheng bismuthshieldaffectingctimagequalityandradiationdoseinadjacentanddistantzonesrelativetoshieldingsurfaceaphantomstudy
AT tsaihuiyu bismuthshieldaffectingctimagequalityandradiationdoseinadjacentanddistantzonesrelativetoshieldingsurfaceaphantomstudy