Cargando…
Right Atrial and Massive Pulmonary Artery Mechanical Thrombectomy Under Echocardiography Guidance Using the FlowTriever System
INTRODUCTION: Management of clot in transit in patients with pulmonary embolism, who are candidates for percutaneous intervention, can be challenging. This is a case report of simultaneous right atrial mechanical thrombectomy under echocardiography guidance and pulmonary artery embolectomy under flu...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6888743/ https://www.ncbi.nlm.nih.gov/pubmed/31828229 http://dx.doi.org/10.1016/j.ejvssr.2019.10.001 |
_version_ | 1783475300731977728 |
---|---|
author | Nezami, Nariman Latich, Igor Murali, Nikitha Ali, Rahmat Lin, Ben A. ShervinRad, Mohammadreza Pollak, Jeffrey Mojibian, Hamid |
author_facet | Nezami, Nariman Latich, Igor Murali, Nikitha Ali, Rahmat Lin, Ben A. ShervinRad, Mohammadreza Pollak, Jeffrey Mojibian, Hamid |
author_sort | Nezami, Nariman |
collection | PubMed |
description | INTRODUCTION: Management of clot in transit in patients with pulmonary embolism, who are candidates for percutaneous intervention, can be challenging. This is a case report of simultaneous right atrial mechanical thrombectomy under echocardiography guidance and pulmonary artery embolectomy under fluoroscopy guidance, using the recently introduced FlowTriever system (Inari Medical Inc., Irvine, CA, USA). REPORT: An 88 year old female, resuscitated from cardiopulmonary arrest near the end of a total right hip arthroplasty, presented for management of suspected massive pulmonary embolism. Her right atrial thrombus was removed under transthoracic echocardiography guidance, and her pulmonary arterial thrombus was subsequently successfully treated under fluoroscopy. DISCUSSION: The FlowTriever system can be safely and effectively used under real time transthoracic echocardiography guidance to retrieve clot in transit from the cardiac chambers, in addition to its standard application for the pulmonary artery under fluoroscopy guidance. |
format | Online Article Text |
id | pubmed-6888743 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-68887432019-12-11 Right Atrial and Massive Pulmonary Artery Mechanical Thrombectomy Under Echocardiography Guidance Using the FlowTriever System Nezami, Nariman Latich, Igor Murali, Nikitha Ali, Rahmat Lin, Ben A. ShervinRad, Mohammadreza Pollak, Jeffrey Mojibian, Hamid EJVES Short Rep Case Report INTRODUCTION: Management of clot in transit in patients with pulmonary embolism, who are candidates for percutaneous intervention, can be challenging. This is a case report of simultaneous right atrial mechanical thrombectomy under echocardiography guidance and pulmonary artery embolectomy under fluoroscopy guidance, using the recently introduced FlowTriever system (Inari Medical Inc., Irvine, CA, USA). REPORT: An 88 year old female, resuscitated from cardiopulmonary arrest near the end of a total right hip arthroplasty, presented for management of suspected massive pulmonary embolism. Her right atrial thrombus was removed under transthoracic echocardiography guidance, and her pulmonary arterial thrombus was subsequently successfully treated under fluoroscopy. DISCUSSION: The FlowTriever system can be safely and effectively used under real time transthoracic echocardiography guidance to retrieve clot in transit from the cardiac chambers, in addition to its standard application for the pulmonary artery under fluoroscopy guidance. Elsevier 2019-11-07 /pmc/articles/PMC6888743/ /pubmed/31828229 http://dx.doi.org/10.1016/j.ejvssr.2019.10.001 Text en © 2019 Published by Elsevier Ltd on behalf of European Society for Vascular Surgery. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Nezami, Nariman Latich, Igor Murali, Nikitha Ali, Rahmat Lin, Ben A. ShervinRad, Mohammadreza Pollak, Jeffrey Mojibian, Hamid Right Atrial and Massive Pulmonary Artery Mechanical Thrombectomy Under Echocardiography Guidance Using the FlowTriever System |
title | Right Atrial and Massive Pulmonary Artery Mechanical Thrombectomy Under Echocardiography Guidance Using the FlowTriever System |
title_full | Right Atrial and Massive Pulmonary Artery Mechanical Thrombectomy Under Echocardiography Guidance Using the FlowTriever System |
title_fullStr | Right Atrial and Massive Pulmonary Artery Mechanical Thrombectomy Under Echocardiography Guidance Using the FlowTriever System |
title_full_unstemmed | Right Atrial and Massive Pulmonary Artery Mechanical Thrombectomy Under Echocardiography Guidance Using the FlowTriever System |
title_short | Right Atrial and Massive Pulmonary Artery Mechanical Thrombectomy Under Echocardiography Guidance Using the FlowTriever System |
title_sort | right atrial and massive pulmonary artery mechanical thrombectomy under echocardiography guidance using the flowtriever system |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6888743/ https://www.ncbi.nlm.nih.gov/pubmed/31828229 http://dx.doi.org/10.1016/j.ejvssr.2019.10.001 |
work_keys_str_mv | AT nezaminariman rightatrialandmassivepulmonaryarterymechanicalthrombectomyunderechocardiographyguidanceusingtheflowtrieversystem AT latichigor rightatrialandmassivepulmonaryarterymechanicalthrombectomyunderechocardiographyguidanceusingtheflowtrieversystem AT muralinikitha rightatrialandmassivepulmonaryarterymechanicalthrombectomyunderechocardiographyguidanceusingtheflowtrieversystem AT alirahmat rightatrialandmassivepulmonaryarterymechanicalthrombectomyunderechocardiographyguidanceusingtheflowtrieversystem AT linbena rightatrialandmassivepulmonaryarterymechanicalthrombectomyunderechocardiographyguidanceusingtheflowtrieversystem AT shervinradmohammadreza rightatrialandmassivepulmonaryarterymechanicalthrombectomyunderechocardiographyguidanceusingtheflowtrieversystem AT pollakjeffrey rightatrialandmassivepulmonaryarterymechanicalthrombectomyunderechocardiographyguidanceusingtheflowtrieversystem AT mojibianhamid rightatrialandmassivepulmonaryarterymechanicalthrombectomyunderechocardiographyguidanceusingtheflowtrieversystem |