Cargando…
MEMS-Based Sensor for Simultaneous Measurement of Pulse Wave and Respiration Rate
The continuous measurements of vital signs (body temperature, blood pressure, pulse wave, and respiration rate) are important in many applications across various fields, including healthcare and sports. To realize such measurements, wearable devices that cause minimal discomfort to the wearers are h...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6891372/ https://www.ncbi.nlm.nih.gov/pubmed/31766200 http://dx.doi.org/10.3390/s19224942 |
_version_ | 1783475798148120576 |
---|---|
author | Nguyen, Thanh-Vinh Ichiki, Masaaki |
author_facet | Nguyen, Thanh-Vinh Ichiki, Masaaki |
author_sort | Nguyen, Thanh-Vinh |
collection | PubMed |
description | The continuous measurements of vital signs (body temperature, blood pressure, pulse wave, and respiration rate) are important in many applications across various fields, including healthcare and sports. To realize such measurements, wearable devices that cause minimal discomfort to the wearers are highly desired. Accordingly, a device that can measure multiple vital signs simultaneously using a single sensing element is important in order to reduce the number of devices attached to the wearer’s body, thereby reducing user discomfort. Thus, in this study, we propose a device with a microelectromechanical systems (MEMS)-based pressure sensor that can simultaneously measure the blood pulse wave and respiration rate using only one sensing element. In particular, in the proposed device, a thin silicone tube, whose inner pressure can be measured via a piezoresistive cantilever, is attached to the nose pad of a pair of eyeglasses. On wearing the eyeglasses, the tube of sensor device is in contact with the area above the angular artery and nasal cavity of the subject, and thus, both pulse wave and breath of the subject cause the tube’s inner pressure to change. We experimentally show that it is possible to extract information related to pulse wave and respiration as the low-frequency and high-frequency components of the sensor signal, respectively. |
format | Online Article Text |
id | pubmed-6891372 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-68913722019-12-12 MEMS-Based Sensor for Simultaneous Measurement of Pulse Wave and Respiration Rate Nguyen, Thanh-Vinh Ichiki, Masaaki Sensors (Basel) Article The continuous measurements of vital signs (body temperature, blood pressure, pulse wave, and respiration rate) are important in many applications across various fields, including healthcare and sports. To realize such measurements, wearable devices that cause minimal discomfort to the wearers are highly desired. Accordingly, a device that can measure multiple vital signs simultaneously using a single sensing element is important in order to reduce the number of devices attached to the wearer’s body, thereby reducing user discomfort. Thus, in this study, we propose a device with a microelectromechanical systems (MEMS)-based pressure sensor that can simultaneously measure the blood pulse wave and respiration rate using only one sensing element. In particular, in the proposed device, a thin silicone tube, whose inner pressure can be measured via a piezoresistive cantilever, is attached to the nose pad of a pair of eyeglasses. On wearing the eyeglasses, the tube of sensor device is in contact with the area above the angular artery and nasal cavity of the subject, and thus, both pulse wave and breath of the subject cause the tube’s inner pressure to change. We experimentally show that it is possible to extract information related to pulse wave and respiration as the low-frequency and high-frequency components of the sensor signal, respectively. MDPI 2019-11-13 /pmc/articles/PMC6891372/ /pubmed/31766200 http://dx.doi.org/10.3390/s19224942 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Nguyen, Thanh-Vinh Ichiki, Masaaki MEMS-Based Sensor for Simultaneous Measurement of Pulse Wave and Respiration Rate |
title | MEMS-Based Sensor for Simultaneous Measurement of Pulse Wave and Respiration Rate |
title_full | MEMS-Based Sensor for Simultaneous Measurement of Pulse Wave and Respiration Rate |
title_fullStr | MEMS-Based Sensor for Simultaneous Measurement of Pulse Wave and Respiration Rate |
title_full_unstemmed | MEMS-Based Sensor for Simultaneous Measurement of Pulse Wave and Respiration Rate |
title_short | MEMS-Based Sensor for Simultaneous Measurement of Pulse Wave and Respiration Rate |
title_sort | mems-based sensor for simultaneous measurement of pulse wave and respiration rate |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6891372/ https://www.ncbi.nlm.nih.gov/pubmed/31766200 http://dx.doi.org/10.3390/s19224942 |
work_keys_str_mv | AT nguyenthanhvinh memsbasedsensorforsimultaneousmeasurementofpulsewaveandrespirationrate AT ichikimasaaki memsbasedsensorforsimultaneousmeasurementofpulsewaveandrespirationrate |