Cargando…

Detection of Structural Vibration with High-Rate Precise Point Positioning: Case Study Results Based on 100 Hz Multi-GNSS Observables and Shake-Table Simulation

This contribution presents and assesses the methodology aiming at the characterization of the structural vibrations with high-rate GNSS measurements. As commonly employed precise point positioning (PPP) based on ionosphere-free linear combination of undifferenced signals may not meet the high requir...

Descripción completa

Detalles Bibliográficos
Autores principales: Paziewski, Jacek, Sieradzki, Rafal, Baryla, Radoslaw
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6891590/
https://www.ncbi.nlm.nih.gov/pubmed/31698812
http://dx.doi.org/10.3390/s19224832
_version_ 1783475852069044224
author Paziewski, Jacek
Sieradzki, Rafal
Baryla, Radoslaw
author_facet Paziewski, Jacek
Sieradzki, Rafal
Baryla, Radoslaw
author_sort Paziewski, Jacek
collection PubMed
description This contribution presents and assesses the methodology aiming at the characterization of the structural vibrations with high-rate GNSS measurements. As commonly employed precise point positioning (PPP) based on ionosphere-free linear combination of undifferenced signals may not meet the high requirements in terms of displacement precision, a modified processing strategy has been proposed. The algorithms were implemented in the own-developed GNSS processing software and validated using the designed experiment. For this purpose, we have set up a field experiment taking advantage of the prototype shake-table, which simulated the dynamic horizontal displacements of the GNSS antenna. The device ensured a periodic motion of the antenna with modifiable characteristics, namely amplitude and frequency. In this experiment, we have set the amplitudes from 1.5 to 9 mm and the frequency to 3.80 Hz. As a dataset, we have used 100 Hz GPS, Galileo, and BDS measurements. The results confirmed a high applicability of the enhanced PPP processing strategy for precise displacement detection. Specifically, it was feasible to obtain the dynamic displacements with precision at the level of millimeters. The differences between the PPP-derived amplitude and the true amplitude of the simulated displacements were in the range of 0.5–1.3 mm, whereas the difference between the detected and benchmark frequency did not exceed 0.026 Hz. Hence, the proposed methodology allows meeting the specific demands of structural displacement monitoring.
format Online
Article
Text
id pubmed-6891590
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-68915902019-12-12 Detection of Structural Vibration with High-Rate Precise Point Positioning: Case Study Results Based on 100 Hz Multi-GNSS Observables and Shake-Table Simulation Paziewski, Jacek Sieradzki, Rafal Baryla, Radoslaw Sensors (Basel) Article This contribution presents and assesses the methodology aiming at the characterization of the structural vibrations with high-rate GNSS measurements. As commonly employed precise point positioning (PPP) based on ionosphere-free linear combination of undifferenced signals may not meet the high requirements in terms of displacement precision, a modified processing strategy has been proposed. The algorithms were implemented in the own-developed GNSS processing software and validated using the designed experiment. For this purpose, we have set up a field experiment taking advantage of the prototype shake-table, which simulated the dynamic horizontal displacements of the GNSS antenna. The device ensured a periodic motion of the antenna with modifiable characteristics, namely amplitude and frequency. In this experiment, we have set the amplitudes from 1.5 to 9 mm and the frequency to 3.80 Hz. As a dataset, we have used 100 Hz GPS, Galileo, and BDS measurements. The results confirmed a high applicability of the enhanced PPP processing strategy for precise displacement detection. Specifically, it was feasible to obtain the dynamic displacements with precision at the level of millimeters. The differences between the PPP-derived amplitude and the true amplitude of the simulated displacements were in the range of 0.5–1.3 mm, whereas the difference between the detected and benchmark frequency did not exceed 0.026 Hz. Hence, the proposed methodology allows meeting the specific demands of structural displacement monitoring. MDPI 2019-11-06 /pmc/articles/PMC6891590/ /pubmed/31698812 http://dx.doi.org/10.3390/s19224832 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Paziewski, Jacek
Sieradzki, Rafal
Baryla, Radoslaw
Detection of Structural Vibration with High-Rate Precise Point Positioning: Case Study Results Based on 100 Hz Multi-GNSS Observables and Shake-Table Simulation
title Detection of Structural Vibration with High-Rate Precise Point Positioning: Case Study Results Based on 100 Hz Multi-GNSS Observables and Shake-Table Simulation
title_full Detection of Structural Vibration with High-Rate Precise Point Positioning: Case Study Results Based on 100 Hz Multi-GNSS Observables and Shake-Table Simulation
title_fullStr Detection of Structural Vibration with High-Rate Precise Point Positioning: Case Study Results Based on 100 Hz Multi-GNSS Observables and Shake-Table Simulation
title_full_unstemmed Detection of Structural Vibration with High-Rate Precise Point Positioning: Case Study Results Based on 100 Hz Multi-GNSS Observables and Shake-Table Simulation
title_short Detection of Structural Vibration with High-Rate Precise Point Positioning: Case Study Results Based on 100 Hz Multi-GNSS Observables and Shake-Table Simulation
title_sort detection of structural vibration with high-rate precise point positioning: case study results based on 100 hz multi-gnss observables and shake-table simulation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6891590/
https://www.ncbi.nlm.nih.gov/pubmed/31698812
http://dx.doi.org/10.3390/s19224832
work_keys_str_mv AT paziewskijacek detectionofstructuralvibrationwithhighrateprecisepointpositioningcasestudyresultsbasedon100hzmultignssobservablesandshaketablesimulation
AT sieradzkirafal detectionofstructuralvibrationwithhighrateprecisepointpositioningcasestudyresultsbasedon100hzmultignssobservablesandshaketablesimulation
AT barylaradoslaw detectionofstructuralvibrationwithhighrateprecisepointpositioningcasestudyresultsbasedon100hzmultignssobservablesandshaketablesimulation