A new finite element based parameter to predict bone fracture
Dual Energy X-Ray Absorptiometry (DXA) is currently the most widely adopted non-invasive clinical technique to assess bone mineral density and bone mineral content in human research and represents the primary tool for the diagnosis of osteoporosis. DXA measures areal bone mineral density, BMD, which...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6894848/ https://www.ncbi.nlm.nih.gov/pubmed/31805121 http://dx.doi.org/10.1371/journal.pone.0225905 |
_version_ | 1783476470690086912 |
---|---|
author | Colombo, Chiara Libonati, Flavia Rinaudo, Luca Bellazzi, Martina Ulivieri, Fabio Massimo Vergani, Laura |
author_facet | Colombo, Chiara Libonati, Flavia Rinaudo, Luca Bellazzi, Martina Ulivieri, Fabio Massimo Vergani, Laura |
author_sort | Colombo, Chiara |
collection | PubMed |
description | Dual Energy X-Ray Absorptiometry (DXA) is currently the most widely adopted non-invasive clinical technique to assess bone mineral density and bone mineral content in human research and represents the primary tool for the diagnosis of osteoporosis. DXA measures areal bone mineral density, BMD, which does not account for the three-dimensional structure of the vertebrae and for the distribution of bone mass. The result is that longitudinal DXA can only predict about 70% of vertebral fractures. This study proposes a complementary tool, based on Finite Element (FE) models, to improve the DXA accuracy. Bone is simulated as elastic and inhomogeneous material, with stiffness distribution derived from DXA greyscale images of density. The numerical procedure simulates a compressive load on each vertebra to evaluate the local minimum principal strain values. From these values, both the local average and the maximum strains are computed over the cross sections and along the height of the analysed bone region, to provide a parameter, named Strain Index of Bone (SIB), which could be considered as a bone fragility index. The procedure is initially validated on 33 cylindrical trabecular bone samples obtained from porcine lumbar vertebrae, experimentally tested under static compressive loading. Comparing the experimental mechanical parameters with the SIB, we could find a higher correlation of the ultimate stress, σ(ULT), with the SIB values (R(2)(adj) = 0.63) than that observed with the conventional DXA-based clinical parameters, i.e. Bone Mineral Density, BMD (R(2)(adj) = 0.34) and Trabecular Bone Score, TBS (R(2)(adj) = -0.03). The paper finally presents a few case studies of numerical simulations carried out on human lumbar vertebrae. If our results are confirmed in prospective studies, SIB could be used—together with BMD and TBS—to improve the fracture risk assessment and support the clinical decision to assume specific drugs for metabolic bone diseases. |
format | Online Article Text |
id | pubmed-6894848 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-68948482019-12-14 A new finite element based parameter to predict bone fracture Colombo, Chiara Libonati, Flavia Rinaudo, Luca Bellazzi, Martina Ulivieri, Fabio Massimo Vergani, Laura PLoS One Research Article Dual Energy X-Ray Absorptiometry (DXA) is currently the most widely adopted non-invasive clinical technique to assess bone mineral density and bone mineral content in human research and represents the primary tool for the diagnosis of osteoporosis. DXA measures areal bone mineral density, BMD, which does not account for the three-dimensional structure of the vertebrae and for the distribution of bone mass. The result is that longitudinal DXA can only predict about 70% of vertebral fractures. This study proposes a complementary tool, based on Finite Element (FE) models, to improve the DXA accuracy. Bone is simulated as elastic and inhomogeneous material, with stiffness distribution derived from DXA greyscale images of density. The numerical procedure simulates a compressive load on each vertebra to evaluate the local minimum principal strain values. From these values, both the local average and the maximum strains are computed over the cross sections and along the height of the analysed bone region, to provide a parameter, named Strain Index of Bone (SIB), which could be considered as a bone fragility index. The procedure is initially validated on 33 cylindrical trabecular bone samples obtained from porcine lumbar vertebrae, experimentally tested under static compressive loading. Comparing the experimental mechanical parameters with the SIB, we could find a higher correlation of the ultimate stress, σ(ULT), with the SIB values (R(2)(adj) = 0.63) than that observed with the conventional DXA-based clinical parameters, i.e. Bone Mineral Density, BMD (R(2)(adj) = 0.34) and Trabecular Bone Score, TBS (R(2)(adj) = -0.03). The paper finally presents a few case studies of numerical simulations carried out on human lumbar vertebrae. If our results are confirmed in prospective studies, SIB could be used—together with BMD and TBS—to improve the fracture risk assessment and support the clinical decision to assume specific drugs for metabolic bone diseases. Public Library of Science 2019-12-05 /pmc/articles/PMC6894848/ /pubmed/31805121 http://dx.doi.org/10.1371/journal.pone.0225905 Text en © 2019 Colombo et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Colombo, Chiara Libonati, Flavia Rinaudo, Luca Bellazzi, Martina Ulivieri, Fabio Massimo Vergani, Laura A new finite element based parameter to predict bone fracture |
title | A new finite element based parameter to predict bone fracture |
title_full | A new finite element based parameter to predict bone fracture |
title_fullStr | A new finite element based parameter to predict bone fracture |
title_full_unstemmed | A new finite element based parameter to predict bone fracture |
title_short | A new finite element based parameter to predict bone fracture |
title_sort | new finite element based parameter to predict bone fracture |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6894848/ https://www.ncbi.nlm.nih.gov/pubmed/31805121 http://dx.doi.org/10.1371/journal.pone.0225905 |
work_keys_str_mv | AT colombochiara anewfiniteelementbasedparametertopredictbonefracture AT libonatiflavia anewfiniteelementbasedparametertopredictbonefracture AT rinaudoluca anewfiniteelementbasedparametertopredictbonefracture AT bellazzimartina anewfiniteelementbasedparametertopredictbonefracture AT ulivierifabiomassimo anewfiniteelementbasedparametertopredictbonefracture AT verganilaura anewfiniteelementbasedparametertopredictbonefracture AT colombochiara newfiniteelementbasedparametertopredictbonefracture AT libonatiflavia newfiniteelementbasedparametertopredictbonefracture AT rinaudoluca newfiniteelementbasedparametertopredictbonefracture AT bellazzimartina newfiniteelementbasedparametertopredictbonefracture AT ulivierifabiomassimo newfiniteelementbasedparametertopredictbonefracture AT verganilaura newfiniteelementbasedparametertopredictbonefracture |