Repeatability of curvature measurements in central and paracentral corneal areas of keratoconus patients using Orbscan and Pentacam

PURPOSE: To determine the repeatability of curvature measurements in 5 corneal rings (1–5 mm from the corneal center) in keratoconus (KCN) patients using the Orbscan and Pentacam and to compare the values of these devices. METHODS: Forty-eight patients with a definite diagnosis of KCN were included...

Descripción completa

Detalles Bibliográficos
Autores principales: Mirzajani, Ali, Asharlous, Amir, Kianpoor, Parvin, Jafarzadehpur, Ebrahim, Yekta, Abbasali, Khabazkhoob, Mehdi, Hashemi, Hassan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6896424/
https://www.ncbi.nlm.nih.gov/pubmed/31844787
http://dx.doi.org/10.1016/j.joco.2018.12.005
_version_ 1783476775491207168
author Mirzajani, Ali
Asharlous, Amir
Kianpoor, Parvin
Jafarzadehpur, Ebrahim
Yekta, Abbasali
Khabazkhoob, Mehdi
Hashemi, Hassan
author_facet Mirzajani, Ali
Asharlous, Amir
Kianpoor, Parvin
Jafarzadehpur, Ebrahim
Yekta, Abbasali
Khabazkhoob, Mehdi
Hashemi, Hassan
author_sort Mirzajani, Ali
collection PubMed
description PURPOSE: To determine the repeatability of curvature measurements in 5 corneal rings (1–5 mm from the corneal center) in keratoconus (KCN) patients using the Orbscan and Pentacam and to compare the values of these devices. METHODS: Forty-eight patients with a definite diagnosis of KCN were included in the study. Patients with any corneal scar or active disease or a history of ocular surgery were excluded from the study. The right eye of the patients was studied three times with the Orbscan and Pentacam. The repeatability of the curvatures of 5 corneal rings (1–5 mm from the corneal center) was evaluated using the Orbscan and Pentacam, and the agreement of their values was analyzed. RESULTS: The intraclass correlation coefficient (ICC) of three measurements was at least 0.94 (P < 0.0001) for the Orbscan and at least 0.88 (P < 0.0001) for the Pentacam in all corneal rings. According to the grade of KCN, the Orbscan had a low ICC in the 2 mm ring in grades 2 and 3 (ICC = 0.750 and 0.298, respectively). Repeated measures ANOVA showed no significant difference between the repeated measurements of the Orbscan and Pentacam in all corneal rings. The paired t-test showed a significant difference in curvature measurements in all rings except for the 5-mm ring between the two devices (P < 0.0001). The Bland-Altman plot showed a week agreement between these two devices in 1–4 mm corneal rings in curvatures more than 45 D. CONCLUSIONS: According to the results of this study, keratometry readings are highly repeatable in Pentacam and Orbscan devices in all corneal rings. Despite the high correlation between curvature measurements of the Orbscan and Pentacam, there was a significant statistical and clinical difference between the results of two devices in all corneal rings (except the 5-mm ring), and the curvature measurements of the Pentacam were steeper than Orbscan measurements.
format Online
Article
Text
id pubmed-6896424
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-68964242019-12-16 Repeatability of curvature measurements in central and paracentral corneal areas of keratoconus patients using Orbscan and Pentacam Mirzajani, Ali Asharlous, Amir Kianpoor, Parvin Jafarzadehpur, Ebrahim Yekta, Abbasali Khabazkhoob, Mehdi Hashemi, Hassan J Curr Ophthalmol Article PURPOSE: To determine the repeatability of curvature measurements in 5 corneal rings (1–5 mm from the corneal center) in keratoconus (KCN) patients using the Orbscan and Pentacam and to compare the values of these devices. METHODS: Forty-eight patients with a definite diagnosis of KCN were included in the study. Patients with any corneal scar or active disease or a history of ocular surgery were excluded from the study. The right eye of the patients was studied three times with the Orbscan and Pentacam. The repeatability of the curvatures of 5 corneal rings (1–5 mm from the corneal center) was evaluated using the Orbscan and Pentacam, and the agreement of their values was analyzed. RESULTS: The intraclass correlation coefficient (ICC) of three measurements was at least 0.94 (P < 0.0001) for the Orbscan and at least 0.88 (P < 0.0001) for the Pentacam in all corneal rings. According to the grade of KCN, the Orbscan had a low ICC in the 2 mm ring in grades 2 and 3 (ICC = 0.750 and 0.298, respectively). Repeated measures ANOVA showed no significant difference between the repeated measurements of the Orbscan and Pentacam in all corneal rings. The paired t-test showed a significant difference in curvature measurements in all rings except for the 5-mm ring between the two devices (P < 0.0001). The Bland-Altman plot showed a week agreement between these two devices in 1–4 mm corneal rings in curvatures more than 45 D. CONCLUSIONS: According to the results of this study, keratometry readings are highly repeatable in Pentacam and Orbscan devices in all corneal rings. Despite the high correlation between curvature measurements of the Orbscan and Pentacam, there was a significant statistical and clinical difference between the results of two devices in all corneal rings (except the 5-mm ring), and the curvature measurements of the Pentacam were steeper than Orbscan measurements. Elsevier 2019-01-23 /pmc/articles/PMC6896424/ /pubmed/31844787 http://dx.doi.org/10.1016/j.joco.2018.12.005 Text en © 2018 Iranian Society of Ophthalmology. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Mirzajani, Ali
Asharlous, Amir
Kianpoor, Parvin
Jafarzadehpur, Ebrahim
Yekta, Abbasali
Khabazkhoob, Mehdi
Hashemi, Hassan
Repeatability of curvature measurements in central and paracentral corneal areas of keratoconus patients using Orbscan and Pentacam
title Repeatability of curvature measurements in central and paracentral corneal areas of keratoconus patients using Orbscan and Pentacam
title_full Repeatability of curvature measurements in central and paracentral corneal areas of keratoconus patients using Orbscan and Pentacam
title_fullStr Repeatability of curvature measurements in central and paracentral corneal areas of keratoconus patients using Orbscan and Pentacam
title_full_unstemmed Repeatability of curvature measurements in central and paracentral corneal areas of keratoconus patients using Orbscan and Pentacam
title_short Repeatability of curvature measurements in central and paracentral corneal areas of keratoconus patients using Orbscan and Pentacam
title_sort repeatability of curvature measurements in central and paracentral corneal areas of keratoconus patients using orbscan and pentacam
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6896424/
https://www.ncbi.nlm.nih.gov/pubmed/31844787
http://dx.doi.org/10.1016/j.joco.2018.12.005
work_keys_str_mv AT mirzajaniali repeatabilityofcurvaturemeasurementsincentralandparacentralcornealareasofkeratoconuspatientsusingorbscanandpentacam
AT asharlousamir repeatabilityofcurvaturemeasurementsincentralandparacentralcornealareasofkeratoconuspatientsusingorbscanandpentacam
AT kianpoorparvin repeatabilityofcurvaturemeasurementsincentralandparacentralcornealareasofkeratoconuspatientsusingorbscanandpentacam
AT jafarzadehpurebrahim repeatabilityofcurvaturemeasurementsincentralandparacentralcornealareasofkeratoconuspatientsusingorbscanandpentacam
AT yektaabbasali repeatabilityofcurvaturemeasurementsincentralandparacentralcornealareasofkeratoconuspatientsusingorbscanandpentacam
AT khabazkhoobmehdi repeatabilityofcurvaturemeasurementsincentralandparacentralcornealareasofkeratoconuspatientsusingorbscanandpentacam
AT hashemihassan repeatabilityofcurvaturemeasurementsincentralandparacentralcornealareasofkeratoconuspatientsusingorbscanandpentacam