Influence of Glenosphere and baseplate parameters on Glenoid bone strains in reverse shoulder Arthroplasty

BACKGROUND: Little is known about the strains at the glenoid near the bone-implant interface in reverse shoulder arthroplasty. The purpose of the current study was to evaluate the strains on the glenoid bone under a compressive load after implantation of three different sizes of metal-backed basepla...

Descripción completa

Detalles Bibliográficos
Autores principales: Pauzenberger, Leo, Dwyer, Cory, Obopilwe, Elifho, Nowak, Michael D., Cote, Mark, Romeo, Anthony A., Mazzocca, Augustus D., Dyrna, Felix
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6896710/
https://www.ncbi.nlm.nih.gov/pubmed/31805924
http://dx.doi.org/10.1186/s12891-019-2968-3
Descripción
Sumario:BACKGROUND: Little is known about the strains at the glenoid near the bone-implant interface in reverse shoulder arthroplasty. The purpose of the current study was to evaluate the strains on the glenoid bone under a compressive load after implantation of three different sizes of metal-backed baseplates in either inferior or superior position in combination with three different sizes of glenospheres and three different glenosphere designs. METHODS: Three sizes of baseplates (small, medium, large) were implanted in thirty-six paired human cadaveric scapulae either inferior, flush with the glenoid neck, or with a 5 mm superior offset. Glenospheres were available in three sizes (36 mm, 39 mm, 42 mm) and designs (standard, 4 mm lateralized, 2.5 mm inferiorized). Specimens were mounted in a servo-hydraulic testing apparatus at a 60° angle between the glenoid and actuator holding the humeral component. Four strain-gauge rosettes were placed around the glenoid rim to measure strains transferred to the scapular bone under a compressive load (750 N) relative to the various baseplate-glenosphere combinations. Following repeated compression, a load-to-failure test was performed. RESULTS: Mean overall registered strains were 161με (range: − 1165 to 2347) at the inferior sensor, −2με (range: − 213 to 90) at the superior sensor, −95με (range: − 381 to 254) at the anterior sensor, and 13με (range: − 298 to 128) at the posterior sensor. Measured bone strains did not show any significant differences across tested baseplate and glenosphere design, size, or positioning combinations (p > 0.05 for all sensors). Furthermore, linear regression analysis did not identify any of the evaluated parameters as an independent influential factor for strains (p > 0.05 for all sensors). Mean load-at-failure was significantly higher in the group of inferior (3347.0 N ± 704.4 N) compared to superior (2763.8 N ± 927.8 N) positioned baseplates (p = 0.046). CONCLUSION: Different baseplate positions, baseplate sizes, glenosphere sizes, and glenosphere design or various combinations of these parameters did not significantly influence the measured bone strains at the glenoid near the bone-implant interface in a contemporary reverse shoulder arthroplasty system. LEVEL OF EVIDENCE: Basic Science Study, Biomechanical Study.