Use of pH reagent strips to verify gastric tube placement in newborns

OBJECTIVE: to confirm the accuracy of the pH test in identifying the placement of the gastric tube in newborns. METHOD: double-blind, diagnostic test study conducted with 162 newborns admitted to a neonatal intensive care unit and an intermediate care unit. The subjects were submitted to enteral int...

Descripción completa

Detalles Bibliográficos
Autores principales: Dias, Flávia de Souza Barbosa, de Almeida, Beatriz Pera, Alvares, Beatriz Regina, Jales, Rodrigo Menezes, Caldas, Jamil Pedro de Siqueira, Carmona, Elenice Valentim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Escola de Enfermagem de Ribeirão Preto / Universidade de São Paulo 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6896807/
https://www.ncbi.nlm.nih.gov/pubmed/31826168
http://dx.doi.org/10.1590/1518-8345.3150.3227
_version_ 1783476860916596736
author Dias, Flávia de Souza Barbosa
de Almeida, Beatriz Pera
Alvares, Beatriz Regina
Jales, Rodrigo Menezes
Caldas, Jamil Pedro de Siqueira
Carmona, Elenice Valentim
author_facet Dias, Flávia de Souza Barbosa
de Almeida, Beatriz Pera
Alvares, Beatriz Regina
Jales, Rodrigo Menezes
Caldas, Jamil Pedro de Siqueira
Carmona, Elenice Valentim
author_sort Dias, Flávia de Souza Barbosa
collection PubMed
description OBJECTIVE: to confirm the accuracy of the pH test in identifying the placement of the gastric tube in newborns. METHOD: double-blind, diagnostic test study conducted with 162 newborns admitted to a neonatal intensive care unit and an intermediate care unit. The subjects were submitted to enteral intubation, followed by pH test with reagent strip, which was analyzed by a nurse, and radiological examination, analyzed by radiologist. Blinding was kept among professionals regarding test results. Diagnostic accuracy analysis of the pH test in relation to the radiological exam was performed. RESULTS: the sample consisted of 56.17% boys, with average birth weight of 1,886.79g (SD 743,41), 32.92 (SD 2.99) weeks of gestational age and the mean pH was 3.36 (SD 1.27). Considering the cutoff point of pH≤5.5, the sensitivity was 96.25%, specificity 50%, positive predictive value 99.35% and negative predictive value 14.29%. CONCLUSION: The pH test performed with reagent strips is sensitive to identify the correct placement of the gastric tube, so it can be used as an adjuvant technique in the evaluation of the gastric tube placement. In interpreting the results, pH ≤5.5 points to correct placement and values > 5.5 require radiological confirmation.
format Online
Article
Text
id pubmed-6896807
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Escola de Enfermagem de Ribeirão Preto / Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-68968072019-12-13 Use of pH reagent strips to verify gastric tube placement in newborns Dias, Flávia de Souza Barbosa de Almeida, Beatriz Pera Alvares, Beatriz Regina Jales, Rodrigo Menezes Caldas, Jamil Pedro de Siqueira Carmona, Elenice Valentim Rev Lat Am Enfermagem Original Article OBJECTIVE: to confirm the accuracy of the pH test in identifying the placement of the gastric tube in newborns. METHOD: double-blind, diagnostic test study conducted with 162 newborns admitted to a neonatal intensive care unit and an intermediate care unit. The subjects were submitted to enteral intubation, followed by pH test with reagent strip, which was analyzed by a nurse, and radiological examination, analyzed by radiologist. Blinding was kept among professionals regarding test results. Diagnostic accuracy analysis of the pH test in relation to the radiological exam was performed. RESULTS: the sample consisted of 56.17% boys, with average birth weight of 1,886.79g (SD 743,41), 32.92 (SD 2.99) weeks of gestational age and the mean pH was 3.36 (SD 1.27). Considering the cutoff point of pH≤5.5, the sensitivity was 96.25%, specificity 50%, positive predictive value 99.35% and negative predictive value 14.29%. CONCLUSION: The pH test performed with reagent strips is sensitive to identify the correct placement of the gastric tube, so it can be used as an adjuvant technique in the evaluation of the gastric tube placement. In interpreting the results, pH ≤5.5 points to correct placement and values > 5.5 require radiological confirmation. Escola de Enfermagem de Ribeirão Preto / Universidade de São Paulo 2019-12-05 /pmc/articles/PMC6896807/ /pubmed/31826168 http://dx.doi.org/10.1590/1518-8345.3150.3227 Text en Copyright © 2019 Revista Latino-Americana de Enfermagem https://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Dias, Flávia de Souza Barbosa
de Almeida, Beatriz Pera
Alvares, Beatriz Regina
Jales, Rodrigo Menezes
Caldas, Jamil Pedro de Siqueira
Carmona, Elenice Valentim
Use of pH reagent strips to verify gastric tube placement in newborns
title Use of pH reagent strips to verify gastric tube placement in newborns
title_full Use of pH reagent strips to verify gastric tube placement in newborns
title_fullStr Use of pH reagent strips to verify gastric tube placement in newborns
title_full_unstemmed Use of pH reagent strips to verify gastric tube placement in newborns
title_short Use of pH reagent strips to verify gastric tube placement in newborns
title_sort use of ph reagent strips to verify gastric tube placement in newborns
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6896807/
https://www.ncbi.nlm.nih.gov/pubmed/31826168
http://dx.doi.org/10.1590/1518-8345.3150.3227
work_keys_str_mv AT diasflaviadesouzabarbosa useofphreagentstripstoverifygastrictubeplacementinnewborns
AT dealmeidabeatrizpera useofphreagentstripstoverifygastrictubeplacementinnewborns
AT alvaresbeatrizregina useofphreagentstripstoverifygastrictubeplacementinnewborns
AT jalesrodrigomenezes useofphreagentstripstoverifygastrictubeplacementinnewborns
AT caldasjamilpedrodesiqueira useofphreagentstripstoverifygastrictubeplacementinnewborns
AT carmonaelenicevalentim useofphreagentstripstoverifygastrictubeplacementinnewborns