High false positive rate of white blood cells in urine samples of pregnant women may be caused by epithelial cells being misclassified by the sysmex UF‐1000i urine flow cytometer

BACKGROUND: The UF‐1000i has been widely used in screening urinary sediments. However, the interference factor of the UF‐1000i in the screening urinary sediments of pregnant women has not been reported. The aim of the study was to demonstrate that epithelial cells (ECs) cause a high false positive r...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Wei, Yu, Xiaochen, Liu, Dan, Guan, Xiuru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6899535/
https://www.ncbi.nlm.nih.gov/pubmed/30302910
http://dx.doi.org/10.1002/cyto.b.21727
_version_ 1783477151162433536
author Yang, Wei
Yu, Xiaochen
Liu, Dan
Guan, Xiuru
author_facet Yang, Wei
Yu, Xiaochen
Liu, Dan
Guan, Xiuru
author_sort Yang, Wei
collection PubMed
description BACKGROUND: The UF‐1000i has been widely used in screening urinary sediments. However, the interference factor of the UF‐1000i in the screening urinary sediments of pregnant women has not been reported. The aim of the study was to demonstrate that epithelial cells (ECs) cause a high false positive rate of white blood cells (WBCs) by the UF‐1000i in pregnant women. METHODS: Urine samples were collected from 207 pregnant women. All samples were measured by the UF‐1000i and a microscopic method. RESULTS: The areas under the curve (AUC) for WBC and EC counts were 0.837 (95% CI, 0.773–0.901) and 0.844 (95% CI, 0.785–0.903), respectively. The positive rates of the WBC and EC were 73.43% and 37.20%, respectively, by the UF‐1000i, and they were 19.32% and 72.95% by the microscopic method. The positive predictive value, negative predictive value, false positive rates, and false negative rates by the UF‐1000i were for WBC 25.66%, 98.18%, 74.34%, and 1.82%, respectively, and for EC they were 96.1%, 40.77%, 3.9%, and 59.23%, respectively. The coefficient of correlation R value was 0.503 (P < 0.01) between WBC by UF‐1000i and EC by the microscopic method in WBC false positive samples. CONCLUSIONS: EC could be an interference factor for the UF‐1000i in screening urinary WBC of pregnant women, and the high false positive rate for WBC may be caused by ECs being misclassified as WBCs by the UF‐1000i. © 2018 The Authors. Cytometry Part B: Clinical Cytometry published by Wiley Periodicals, Inc. on behalf of International Clinical Cytometry Society.
format Online
Article
Text
id pubmed-6899535
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-68995352019-12-19 High false positive rate of white blood cells in urine samples of pregnant women may be caused by epithelial cells being misclassified by the sysmex UF‐1000i urine flow cytometer Yang, Wei Yu, Xiaochen Liu, Dan Guan, Xiuru Cytometry B Clin Cytom Original Articles BACKGROUND: The UF‐1000i has been widely used in screening urinary sediments. However, the interference factor of the UF‐1000i in the screening urinary sediments of pregnant women has not been reported. The aim of the study was to demonstrate that epithelial cells (ECs) cause a high false positive rate of white blood cells (WBCs) by the UF‐1000i in pregnant women. METHODS: Urine samples were collected from 207 pregnant women. All samples were measured by the UF‐1000i and a microscopic method. RESULTS: The areas under the curve (AUC) for WBC and EC counts were 0.837 (95% CI, 0.773–0.901) and 0.844 (95% CI, 0.785–0.903), respectively. The positive rates of the WBC and EC were 73.43% and 37.20%, respectively, by the UF‐1000i, and they were 19.32% and 72.95% by the microscopic method. The positive predictive value, negative predictive value, false positive rates, and false negative rates by the UF‐1000i were for WBC 25.66%, 98.18%, 74.34%, and 1.82%, respectively, and for EC they were 96.1%, 40.77%, 3.9%, and 59.23%, respectively. The coefficient of correlation R value was 0.503 (P < 0.01) between WBC by UF‐1000i and EC by the microscopic method in WBC false positive samples. CONCLUSIONS: EC could be an interference factor for the UF‐1000i in screening urinary WBC of pregnant women, and the high false positive rate for WBC may be caused by ECs being misclassified as WBCs by the UF‐1000i. © 2018 The Authors. Cytometry Part B: Clinical Cytometry published by Wiley Periodicals, Inc. on behalf of International Clinical Cytometry Society. John Wiley & Sons, Inc. 2018-10-10 2019-11 /pmc/articles/PMC6899535/ /pubmed/30302910 http://dx.doi.org/10.1002/cyto.b.21727 Text en © 2018 The Authors. Cytometry Part B: Clinical Cytometry published by Wiley Periodicals, Inc. on behalf of International Clinical Cytometry Society. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Articles
Yang, Wei
Yu, Xiaochen
Liu, Dan
Guan, Xiuru
High false positive rate of white blood cells in urine samples of pregnant women may be caused by epithelial cells being misclassified by the sysmex UF‐1000i urine flow cytometer
title High false positive rate of white blood cells in urine samples of pregnant women may be caused by epithelial cells being misclassified by the sysmex UF‐1000i urine flow cytometer
title_full High false positive rate of white blood cells in urine samples of pregnant women may be caused by epithelial cells being misclassified by the sysmex UF‐1000i urine flow cytometer
title_fullStr High false positive rate of white blood cells in urine samples of pregnant women may be caused by epithelial cells being misclassified by the sysmex UF‐1000i urine flow cytometer
title_full_unstemmed High false positive rate of white blood cells in urine samples of pregnant women may be caused by epithelial cells being misclassified by the sysmex UF‐1000i urine flow cytometer
title_short High false positive rate of white blood cells in urine samples of pregnant women may be caused by epithelial cells being misclassified by the sysmex UF‐1000i urine flow cytometer
title_sort high false positive rate of white blood cells in urine samples of pregnant women may be caused by epithelial cells being misclassified by the sysmex uf‐1000i urine flow cytometer
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6899535/
https://www.ncbi.nlm.nih.gov/pubmed/30302910
http://dx.doi.org/10.1002/cyto.b.21727
work_keys_str_mv AT yangwei highfalsepositiverateofwhitebloodcellsinurinesamplesofpregnantwomenmaybecausedbyepithelialcellsbeingmisclassifiedbythesysmexuf1000iurineflowcytometer
AT yuxiaochen highfalsepositiverateofwhitebloodcellsinurinesamplesofpregnantwomenmaybecausedbyepithelialcellsbeingmisclassifiedbythesysmexuf1000iurineflowcytometer
AT liudan highfalsepositiverateofwhitebloodcellsinurinesamplesofpregnantwomenmaybecausedbyepithelialcellsbeingmisclassifiedbythesysmexuf1000iurineflowcytometer
AT guanxiuru highfalsepositiverateofwhitebloodcellsinurinesamplesofpregnantwomenmaybecausedbyepithelialcellsbeingmisclassifiedbythesysmexuf1000iurineflowcytometer