Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement
PURPOSE: This work demonstrates specifically tailored microbubble‐based preparations and their suitability as MRI contrast agents for ingestion and measuring temporal and spatial pressure variation in the human stomach. METHODS: Enhanced alginate spheres were prepared by incorporating gas‐filled mic...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6899603/ https://www.ncbi.nlm.nih.gov/pubmed/31524306 http://dx.doi.org/10.1002/mrm.27992 |
_version_ | 1783477166678212608 |
---|---|
author | Abdurakman, Edwin Bencsik, Martin Cave, Gareth W. V. Hoad, Caroline L. McGowan, Scott Fairhurst, David J. Major, Giles Gowland, Penny A. Bowtell, Richard |
author_facet | Abdurakman, Edwin Bencsik, Martin Cave, Gareth W. V. Hoad, Caroline L. McGowan, Scott Fairhurst, David J. Major, Giles Gowland, Penny A. Bowtell, Richard |
author_sort | Abdurakman, Edwin |
collection | PubMed |
description | PURPOSE: This work demonstrates specifically tailored microbubble‐based preparations and their suitability as MRI contrast agents for ingestion and measuring temporal and spatial pressure variation in the human stomach. METHODS: Enhanced alginate spheres were prepared by incorporating gas‐filled microbubbles into sodium alginate solution followed by the polymerization of the mixture in an aqueous calcium lactate solution. The microbubbles were prepared with a phospholipid shell and perfluorocarbon gas filling, using a mechanical cavitational agitation regime. The NMR signal changes to externally applied pressure and coming from the enhanced alginate spheres were acquired and compared with that of alginate spheres without microbubbles. In vivo investigations were also carried out on healthy volunteers to measure the pressure variation in the stomach. RESULTS: The MR signal changes in the contrast agent exhibits a linear sensitivity of approximately 40% per bar, as opposed to no measurable signal change seen in the control gas‐free spheres. This novel contrast agent also demonstrates an excellent stability in simulated gastric conditions, including at body temperature. In vivo studies showed that the signal change exhibited in the meal within the antrum region is between 5% and 10%, but appears to come from both pressure changes and partial volume artifacts. CONCLUSION: This study demonstrates that alginate spheres with microbubbles can be used as an MRI contrast agent to measure pressure changes. The peristaltic movement within the stomach is seen to substantially alter the overall signal intensity of the contrast agent meal. Future work must focus on improving the contrast agent's sensitivity to pressure changes. |
format | Online Article Text |
id | pubmed-6899603 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-68996032019-12-19 Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement Abdurakman, Edwin Bencsik, Martin Cave, Gareth W. V. Hoad, Caroline L. McGowan, Scott Fairhurst, David J. Major, Giles Gowland, Penny A. Bowtell, Richard Magn Reson Med Full Papers—Biophysics and Basic Biomedical Research PURPOSE: This work demonstrates specifically tailored microbubble‐based preparations and their suitability as MRI contrast agents for ingestion and measuring temporal and spatial pressure variation in the human stomach. METHODS: Enhanced alginate spheres were prepared by incorporating gas‐filled microbubbles into sodium alginate solution followed by the polymerization of the mixture in an aqueous calcium lactate solution. The microbubbles were prepared with a phospholipid shell and perfluorocarbon gas filling, using a mechanical cavitational agitation regime. The NMR signal changes to externally applied pressure and coming from the enhanced alginate spheres were acquired and compared with that of alginate spheres without microbubbles. In vivo investigations were also carried out on healthy volunteers to measure the pressure variation in the stomach. RESULTS: The MR signal changes in the contrast agent exhibits a linear sensitivity of approximately 40% per bar, as opposed to no measurable signal change seen in the control gas‐free spheres. This novel contrast agent also demonstrates an excellent stability in simulated gastric conditions, including at body temperature. In vivo studies showed that the signal change exhibited in the meal within the antrum region is between 5% and 10%, but appears to come from both pressure changes and partial volume artifacts. CONCLUSION: This study demonstrates that alginate spheres with microbubbles can be used as an MRI contrast agent to measure pressure changes. The peristaltic movement within the stomach is seen to substantially alter the overall signal intensity of the contrast agent meal. Future work must focus on improving the contrast agent's sensitivity to pressure changes. John Wiley and Sons Inc. 2019-09-16 2020-03 /pmc/articles/PMC6899603/ /pubmed/31524306 http://dx.doi.org/10.1002/mrm.27992 Text en © 2019 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Full Papers—Biophysics and Basic Biomedical Research Abdurakman, Edwin Bencsik, Martin Cave, Gareth W. V. Hoad, Caroline L. McGowan, Scott Fairhurst, David J. Major, Giles Gowland, Penny A. Bowtell, Richard Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement |
title | Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement |
title_full | Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement |
title_fullStr | Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement |
title_full_unstemmed | Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement |
title_short | Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement |
title_sort | design and testing of microbubble‐based mri contrast agents for gastric pressure measurement |
topic | Full Papers—Biophysics and Basic Biomedical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6899603/ https://www.ncbi.nlm.nih.gov/pubmed/31524306 http://dx.doi.org/10.1002/mrm.27992 |
work_keys_str_mv | AT abdurakmanedwin designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement AT bencsikmartin designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement AT cavegarethwv designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement AT hoadcarolinel designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement AT mcgowanscott designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement AT fairhurstdavidj designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement AT majorgiles designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement AT gowlandpennya designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement AT bowtellrichard designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement |