Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement

PURPOSE: This work demonstrates specifically tailored microbubble‐based preparations and their suitability as MRI contrast agents for ingestion and measuring temporal and spatial pressure variation in the human stomach. METHODS: Enhanced alginate spheres were prepared by incorporating gas‐filled mic...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdurakman, Edwin, Bencsik, Martin, Cave, Gareth W. V., Hoad, Caroline L., McGowan, Scott, Fairhurst, David J., Major, Giles, Gowland, Penny A., Bowtell, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6899603/
https://www.ncbi.nlm.nih.gov/pubmed/31524306
http://dx.doi.org/10.1002/mrm.27992
_version_ 1783477166678212608
author Abdurakman, Edwin
Bencsik, Martin
Cave, Gareth W. V.
Hoad, Caroline L.
McGowan, Scott
Fairhurst, David J.
Major, Giles
Gowland, Penny A.
Bowtell, Richard
author_facet Abdurakman, Edwin
Bencsik, Martin
Cave, Gareth W. V.
Hoad, Caroline L.
McGowan, Scott
Fairhurst, David J.
Major, Giles
Gowland, Penny A.
Bowtell, Richard
author_sort Abdurakman, Edwin
collection PubMed
description PURPOSE: This work demonstrates specifically tailored microbubble‐based preparations and their suitability as MRI contrast agents for ingestion and measuring temporal and spatial pressure variation in the human stomach. METHODS: Enhanced alginate spheres were prepared by incorporating gas‐filled microbubbles into sodium alginate solution followed by the polymerization of the mixture in an aqueous calcium lactate solution. The microbubbles were prepared with a phospholipid shell and perfluorocarbon gas filling, using a mechanical cavitational agitation regime. The NMR signal changes to externally applied pressure and coming from the enhanced alginate spheres were acquired and compared with that of alginate spheres without microbubbles. In vivo investigations were also carried out on healthy volunteers to measure the pressure variation in the stomach. RESULTS: The MR signal changes in the contrast agent exhibits a linear sensitivity of approximately 40% per bar, as opposed to no measurable signal change seen in the control gas‐free spheres. This novel contrast agent also demonstrates an excellent stability in simulated gastric conditions, including at body temperature. In vivo studies showed that the signal change exhibited in the meal within the antrum region is between 5% and 10%, but appears to come from both pressure changes and partial volume artifacts. CONCLUSION: This study demonstrates that alginate spheres with microbubbles can be used as an MRI contrast agent to measure pressure changes. The peristaltic movement within the stomach is seen to substantially alter the overall signal intensity of the contrast agent meal. Future work must focus on improving the contrast agent's sensitivity to pressure changes.
format Online
Article
Text
id pubmed-6899603
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-68996032019-12-19 Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement Abdurakman, Edwin Bencsik, Martin Cave, Gareth W. V. Hoad, Caroline L. McGowan, Scott Fairhurst, David J. Major, Giles Gowland, Penny A. Bowtell, Richard Magn Reson Med Full Papers—Biophysics and Basic Biomedical Research PURPOSE: This work demonstrates specifically tailored microbubble‐based preparations and their suitability as MRI contrast agents for ingestion and measuring temporal and spatial pressure variation in the human stomach. METHODS: Enhanced alginate spheres were prepared by incorporating gas‐filled microbubbles into sodium alginate solution followed by the polymerization of the mixture in an aqueous calcium lactate solution. The microbubbles were prepared with a phospholipid shell and perfluorocarbon gas filling, using a mechanical cavitational agitation regime. The NMR signal changes to externally applied pressure and coming from the enhanced alginate spheres were acquired and compared with that of alginate spheres without microbubbles. In vivo investigations were also carried out on healthy volunteers to measure the pressure variation in the stomach. RESULTS: The MR signal changes in the contrast agent exhibits a linear sensitivity of approximately 40% per bar, as opposed to no measurable signal change seen in the control gas‐free spheres. This novel contrast agent also demonstrates an excellent stability in simulated gastric conditions, including at body temperature. In vivo studies showed that the signal change exhibited in the meal within the antrum region is between 5% and 10%, but appears to come from both pressure changes and partial volume artifacts. CONCLUSION: This study demonstrates that alginate spheres with microbubbles can be used as an MRI contrast agent to measure pressure changes. The peristaltic movement within the stomach is seen to substantially alter the overall signal intensity of the contrast agent meal. Future work must focus on improving the contrast agent's sensitivity to pressure changes. John Wiley and Sons Inc. 2019-09-16 2020-03 /pmc/articles/PMC6899603/ /pubmed/31524306 http://dx.doi.org/10.1002/mrm.27992 Text en © 2019 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Papers—Biophysics and Basic Biomedical Research
Abdurakman, Edwin
Bencsik, Martin
Cave, Gareth W. V.
Hoad, Caroline L.
McGowan, Scott
Fairhurst, David J.
Major, Giles
Gowland, Penny A.
Bowtell, Richard
Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement
title Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement
title_full Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement
title_fullStr Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement
title_full_unstemmed Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement
title_short Design and testing of microbubble‐based MRI contrast agents for gastric pressure measurement
title_sort design and testing of microbubble‐based mri contrast agents for gastric pressure measurement
topic Full Papers—Biophysics and Basic Biomedical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6899603/
https://www.ncbi.nlm.nih.gov/pubmed/31524306
http://dx.doi.org/10.1002/mrm.27992
work_keys_str_mv AT abdurakmanedwin designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement
AT bencsikmartin designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement
AT cavegarethwv designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement
AT hoadcarolinel designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement
AT mcgowanscott designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement
AT fairhurstdavidj designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement
AT majorgiles designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement
AT gowlandpennya designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement
AT bowtellrichard designandtestingofmicrobubblebasedmricontrastagentsforgastricpressuremeasurement