Comparing Three Established Methods for Tinnitus Pitch Matching With Respect to Reliability, Matching Duration, and Subjective Satisfaction

The pitch of tinnitus sound is a key characteristic that is of importance to research and sound therapies relying on exact tinnitus pitch matches. The identification of this tinnitus pitch is a challenging task as there is no objective measurement available. During the tinnitus pitch-matching proced...

Descripción completa

Detalles Bibliográficos
Autores principales: Neff, Patrick, Langguth, Berthold, Schecklmann, Martin, Hannemann, Ronny, Schlee, Winfried
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6900670/
https://www.ncbi.nlm.nih.gov/pubmed/31805822
http://dx.doi.org/10.1177/2331216519887247
_version_ 1783477391364980736
author Neff, Patrick
Langguth, Berthold
Schecklmann, Martin
Hannemann, Ronny
Schlee, Winfried
author_facet Neff, Patrick
Langguth, Berthold
Schecklmann, Martin
Hannemann, Ronny
Schlee, Winfried
author_sort Neff, Patrick
collection PubMed
description The pitch of tinnitus sound is a key characteristic that is of importance to research and sound therapies relying on exact tinnitus pitch matches. The identification of this tinnitus pitch is a challenging task as there is no objective measurement available. During the tinnitus pitch-matching procedure, the participant identifies an external sound that is most similar to the subjective perception of the tinnitus. Several methods have been developed to perform this pitch-matching procedure with tinnitus sufferers. In this study, we aimed to compare the method of adjustment, the two-alternative forced-choice (2AFC) method, and the likeness rating (LR) with respect to reliability, matching duration, and subjective satisfaction. Fifty-nine participants with chronic tinnitus were recruited and performed five consecutive runs of tinnitus matching. The participants were randomized to the three different pitch-matching methods. The intraclass correlation coefficients were .67 for method of adjustment, .63 for 2AFC, and .69 for LR, which can be interpreted as good reliability for all the three methods. However, the 2AFC method revealed significant larger within-subject variability than the other measures. Across the five runs and the three different methods, all participants learned to perform the pitch matching faster and with better self-rated accuracy. Comparing the three pitch-matching methods, LR is more time consuming and the participants were less satisfied with the 2AFC method. Overall, the three pitch-matching methods show good reliability. However, we identified differential aspects for improvement in all methods, which are discussed in this article.
format Online
Article
Text
id pubmed-6900670
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-69006702019-12-13 Comparing Three Established Methods for Tinnitus Pitch Matching With Respect to Reliability, Matching Duration, and Subjective Satisfaction Neff, Patrick Langguth, Berthold Schecklmann, Martin Hannemann, Ronny Schlee, Winfried Trends Hear Original Article The pitch of tinnitus sound is a key characteristic that is of importance to research and sound therapies relying on exact tinnitus pitch matches. The identification of this tinnitus pitch is a challenging task as there is no objective measurement available. During the tinnitus pitch-matching procedure, the participant identifies an external sound that is most similar to the subjective perception of the tinnitus. Several methods have been developed to perform this pitch-matching procedure with tinnitus sufferers. In this study, we aimed to compare the method of adjustment, the two-alternative forced-choice (2AFC) method, and the likeness rating (LR) with respect to reliability, matching duration, and subjective satisfaction. Fifty-nine participants with chronic tinnitus were recruited and performed five consecutive runs of tinnitus matching. The participants were randomized to the three different pitch-matching methods. The intraclass correlation coefficients were .67 for method of adjustment, .63 for 2AFC, and .69 for LR, which can be interpreted as good reliability for all the three methods. However, the 2AFC method revealed significant larger within-subject variability than the other measures. Across the five runs and the three different methods, all participants learned to perform the pitch matching faster and with better self-rated accuracy. Comparing the three pitch-matching methods, LR is more time consuming and the participants were less satisfied with the 2AFC method. Overall, the three pitch-matching methods show good reliability. However, we identified differential aspects for improvement in all methods, which are discussed in this article. SAGE Publications 2019-12-05 /pmc/articles/PMC6900670/ /pubmed/31805822 http://dx.doi.org/10.1177/2331216519887247 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Neff, Patrick
Langguth, Berthold
Schecklmann, Martin
Hannemann, Ronny
Schlee, Winfried
Comparing Three Established Methods for Tinnitus Pitch Matching With Respect to Reliability, Matching Duration, and Subjective Satisfaction
title Comparing Three Established Methods for Tinnitus Pitch Matching With Respect to Reliability, Matching Duration, and Subjective Satisfaction
title_full Comparing Three Established Methods for Tinnitus Pitch Matching With Respect to Reliability, Matching Duration, and Subjective Satisfaction
title_fullStr Comparing Three Established Methods for Tinnitus Pitch Matching With Respect to Reliability, Matching Duration, and Subjective Satisfaction
title_full_unstemmed Comparing Three Established Methods for Tinnitus Pitch Matching With Respect to Reliability, Matching Duration, and Subjective Satisfaction
title_short Comparing Three Established Methods for Tinnitus Pitch Matching With Respect to Reliability, Matching Duration, and Subjective Satisfaction
title_sort comparing three established methods for tinnitus pitch matching with respect to reliability, matching duration, and subjective satisfaction
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6900670/
https://www.ncbi.nlm.nih.gov/pubmed/31805822
http://dx.doi.org/10.1177/2331216519887247
work_keys_str_mv AT neffpatrick comparingthreeestablishedmethodsfortinnituspitchmatchingwithrespecttoreliabilitymatchingdurationandsubjectivesatisfaction
AT langguthberthold comparingthreeestablishedmethodsfortinnituspitchmatchingwithrespecttoreliabilitymatchingdurationandsubjectivesatisfaction
AT schecklmannmartin comparingthreeestablishedmethodsfortinnituspitchmatchingwithrespecttoreliabilitymatchingdurationandsubjectivesatisfaction
AT hannemannronny comparingthreeestablishedmethodsfortinnituspitchmatchingwithrespecttoreliabilitymatchingdurationandsubjectivesatisfaction
AT schleewinfried comparingthreeestablishedmethodsfortinnituspitchmatchingwithrespecttoreliabilitymatchingdurationandsubjectivesatisfaction