Cargando…

Advantages and disadvantages of the ENVOY 6F distal access guiding catheter in endovascular coiling for anterior circulation aneurysms

OBJECTIVE: Selecting an appropriate guiding catheter to provide both sufficient supportability for working devices and sufficient distal navigability is essential for ensuring the success of a procedure. This study aimed to evaluate the advantages and disadvantages of using the ENVOY 6F distal acces...

Descripción completa

Detalles Bibliográficos
Autores principales: Baek, Jin Wook, Jin, Sung-Chul, Kim, Sung-Tae, Heo, Young Jin, Han, Ji Yeon, Seo, Jung Hwa, Paeng, Sung Hwa, Kim, Jung Soo, Jeong, Hae Woong, Jeong, Young-Gyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Cerebrovascular Surgeons; Society of Korean Endovascular Neurosurgeons 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6901813/
https://www.ncbi.nlm.nih.gov/pubmed/31832381
http://dx.doi.org/10.7461/jcen.2019.21.1.5
Descripción
Sumario:OBJECTIVE: Selecting an appropriate guiding catheter to provide both sufficient supportability for working devices and sufficient distal navigability is essential for ensuring the success of a procedure. This study aimed to evaluate the advantages and disadvantages of using the ENVOY 6F distal access (DA) guiding catheter in coil embolization of anterior circulation cerebral aneurysms. METHODS: We included 98 patients (72 [73.5%] women, median age: 63 [range: 25–84] years) who underwent endovascular coiling with the ENVOY 6F DA guiding catheter from May to November 2016. We analyzed data on patient demographics and the number of co-axial techniques to position the guiding catheter, initial and final location of the catheter, and complications related to the catheter. RESULTS: The co-axial technique was used to position the ENVOY 6F DA guiding catheter in the internal carotid artery (ICA) in 20 cases (20.41%). The initial position of the ENVOY 6F DA guiding catheter involved the cervical ICA (79.6%), horizontal petrous ICA (17.3%), and vertical petrous ICA (3.1%). Final control angiograms after endovascular coiling showed proximal change in the final, compared to the initial, position of the ENVOY 6F DA guiding catheter in 25 cases (25.51%). Procedure-related complications were observed in nine patients (9.18%), involving vasospasm in all cases; however, there was no symptomatic case. CONCLUSION: The ENVOY 6F DA guiding catheter had relatively sufficient distal navigability without symptomatic procedural complications. However, the change in the catheter position after endovascular coiling denoted insufficient supportability.