Cargando…
Intrathrombus polymer coating deposition: a pilot study of 91 patients undergoing endovascular therapy for acute large vessel stroke. Part I: Histologic frequency
BACKGROUND: Polymer coating embolism due to vascular medical device use is an increasingly recognized iatrogenic complication. This phenomenon has been linked with various adverse effects including neuroinflammation, acute ischemic stroke, cerebral hemorrhage, and death. Notably, procedure- and devi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6902067/ https://www.ncbi.nlm.nih.gov/pubmed/31103995 http://dx.doi.org/10.1136/neurintsurg-2018-014684 |
_version_ | 1783477617347788800 |
---|---|
author | Mehta, Rashi I Rai, Ansaar T Vos, Jeffrey A Solis, Orestes E Mehta, Rupal I |
author_facet | Mehta, Rashi I Rai, Ansaar T Vos, Jeffrey A Solis, Orestes E Mehta, Rupal I |
author_sort | Mehta, Rashi I |
collection | PubMed |
description | BACKGROUND: Polymer coating embolism due to vascular medical device use is an increasingly recognized iatrogenic complication. This phenomenon has been linked with various adverse effects including neuroinflammation, acute ischemic stroke, cerebral hemorrhage, and death. Notably, procedure- and device-specific risks of this complication are poorly investigated. In this study, we evaluate the detectable frequency of intra-arterial polymer coating delamination among patients who underwent endovascular thrombectomy for treatment of acute ischemic stroke due to large vessel occlusion. METHODS: Ninety-two cerebral thrombectomy specimens were retrospectively analyzed for the presence of polymer coating particulates. Histologic findings were correlated with demographic and procedural details and patient outcomes. RESULTS: Evidence of polymer coating deposition was found in 30 of 92 extracted thrombi (33%). No correlation between intrathrombus polymer deposition and use of a specific thrombectomy device such as a stent retriever, aspiration catheter, or guide catheter was found. However, heterogeneous patterns of device use suggest a number of culprit devices. A trend toward longer procedure times and multiple thrombectomy passes was noted in positive cases. Intrathrombus polymer deposition was not associated with adverse clinical outcomes as measured by the 90-day modified Rankin Scale (mRS); however, small sample size and follow-up intervals limit interpretation. Ninety-day outcomes based on mRS may not fully capture the clinical effects of acute and/or delayed intracerebral polymer complications. CONCLUSION: In light of documented adverse neurologic effects, the frequency of intrathrombus polymer particulates indicates the need for consensus testing methods and large-scale long-term prospective clinical device trials, with inclusion of relevant endpoints to better assess biomaterial and device risks to patients. |
format | Online Article Text |
id | pubmed-6902067 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-69020672019-12-24 Intrathrombus polymer coating deposition: a pilot study of 91 patients undergoing endovascular therapy for acute large vessel stroke. Part I: Histologic frequency Mehta, Rashi I Rai, Ansaar T Vos, Jeffrey A Solis, Orestes E Mehta, Rupal I J Neurointerv Surg Ischemic Stroke BACKGROUND: Polymer coating embolism due to vascular medical device use is an increasingly recognized iatrogenic complication. This phenomenon has been linked with various adverse effects including neuroinflammation, acute ischemic stroke, cerebral hemorrhage, and death. Notably, procedure- and device-specific risks of this complication are poorly investigated. In this study, we evaluate the detectable frequency of intra-arterial polymer coating delamination among patients who underwent endovascular thrombectomy for treatment of acute ischemic stroke due to large vessel occlusion. METHODS: Ninety-two cerebral thrombectomy specimens were retrospectively analyzed for the presence of polymer coating particulates. Histologic findings were correlated with demographic and procedural details and patient outcomes. RESULTS: Evidence of polymer coating deposition was found in 30 of 92 extracted thrombi (33%). No correlation between intrathrombus polymer deposition and use of a specific thrombectomy device such as a stent retriever, aspiration catheter, or guide catheter was found. However, heterogeneous patterns of device use suggest a number of culprit devices. A trend toward longer procedure times and multiple thrombectomy passes was noted in positive cases. Intrathrombus polymer deposition was not associated with adverse clinical outcomes as measured by the 90-day modified Rankin Scale (mRS); however, small sample size and follow-up intervals limit interpretation. Ninety-day outcomes based on mRS may not fully capture the clinical effects of acute and/or delayed intracerebral polymer complications. CONCLUSION: In light of documented adverse neurologic effects, the frequency of intrathrombus polymer particulates indicates the need for consensus testing methods and large-scale long-term prospective clinical device trials, with inclusion of relevant endpoints to better assess biomaterial and device risks to patients. BMJ Publishing Group 2019-12 2019-05-18 /pmc/articles/PMC6902067/ /pubmed/31103995 http://dx.doi.org/10.1136/neurintsurg-2018-014684 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution 4.0 Unported (CC BY 4.0) license, which permits others to copy, redistribute, remix, transform and build upon this work for any purpose, provided the original work is properly cited, a link to the licence is given, and indication of whether changes were made. See: https://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Ischemic Stroke Mehta, Rashi I Rai, Ansaar T Vos, Jeffrey A Solis, Orestes E Mehta, Rupal I Intrathrombus polymer coating deposition: a pilot study of 91 patients undergoing endovascular therapy for acute large vessel stroke. Part I: Histologic frequency |
title | Intrathrombus polymer coating deposition: a pilot study of 91 patients undergoing endovascular therapy for acute large vessel stroke. Part I: Histologic frequency |
title_full | Intrathrombus polymer coating deposition: a pilot study of 91 patients undergoing endovascular therapy for acute large vessel stroke. Part I: Histologic frequency |
title_fullStr | Intrathrombus polymer coating deposition: a pilot study of 91 patients undergoing endovascular therapy for acute large vessel stroke. Part I: Histologic frequency |
title_full_unstemmed | Intrathrombus polymer coating deposition: a pilot study of 91 patients undergoing endovascular therapy for acute large vessel stroke. Part I: Histologic frequency |
title_short | Intrathrombus polymer coating deposition: a pilot study of 91 patients undergoing endovascular therapy for acute large vessel stroke. Part I: Histologic frequency |
title_sort | intrathrombus polymer coating deposition: a pilot study of 91 patients undergoing endovascular therapy for acute large vessel stroke. part i: histologic frequency |
topic | Ischemic Stroke |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6902067/ https://www.ncbi.nlm.nih.gov/pubmed/31103995 http://dx.doi.org/10.1136/neurintsurg-2018-014684 |
work_keys_str_mv | AT mehtarashii intrathrombuspolymercoatingdepositionapilotstudyof91patientsundergoingendovasculartherapyforacutelargevesselstrokepartihistologicfrequency AT raiansaart intrathrombuspolymercoatingdepositionapilotstudyof91patientsundergoingendovasculartherapyforacutelargevesselstrokepartihistologicfrequency AT vosjeffreya intrathrombuspolymercoatingdepositionapilotstudyof91patientsundergoingendovasculartherapyforacutelargevesselstrokepartihistologicfrequency AT solisorestese intrathrombuspolymercoatingdepositionapilotstudyof91patientsundergoingendovasculartherapyforacutelargevesselstrokepartihistologicfrequency AT mehtarupali intrathrombuspolymercoatingdepositionapilotstudyof91patientsundergoingendovasculartherapyforacutelargevesselstrokepartihistologicfrequency |