Do Rotation and Measurement Methods Affect Reliability of Anterior Cruciate Ligament Tunnel Position on 3D Reconstructed Computed Tomography?

BACKGROUND: The literature has seldom investigated the anterior cruciate ligament (ACL) tunnel position while considering the effect of rotation of 3-dimensional computed tomography (3D-CT) images during measurements. HYPOTHESIS: We hypothesized that (1) measurement of the ACL tunnel position in the...

Descripción completa

Detalles Bibliográficos
Autores principales: Moon, Hyun-Soo, Choi, Chong-Hyuk, Jung, Min, Lee, Dae-Young, Chang, Hsienhao, Kim, Sung-Hwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6902393/
https://www.ncbi.nlm.nih.gov/pubmed/31840029
http://dx.doi.org/10.1177/2325967119885882
_version_ 1783477659412463616
author Moon, Hyun-Soo
Choi, Chong-Hyuk
Jung, Min
Lee, Dae-Young
Chang, Hsienhao
Kim, Sung-Hwan
author_facet Moon, Hyun-Soo
Choi, Chong-Hyuk
Jung, Min
Lee, Dae-Young
Chang, Hsienhao
Kim, Sung-Hwan
author_sort Moon, Hyun-Soo
collection PubMed
description BACKGROUND: The literature has seldom investigated the anterior cruciate ligament (ACL) tunnel position while considering the effect of rotation of 3-dimensional computed tomography (3D-CT) images during measurements. HYPOTHESIS: We hypothesized that (1) measurement of the ACL tunnel position in the femur and tibia through use of 3D-CT is considerably influenced by rotation of the 3D model and (2) there exists a reliable measurement method for ACL tunnel position least affected by rotation. STUDY DESIGN: Controlled laboratory study. METHODS: The 3D-CT images of 30 randomly selected patients who underwent single-bundle ACL reconstruction were retrospectively reviewed. For femoral tunnel assessments, rectangular reference frames were used that involved the highest point of the intercondylar notch and outer margins of the lateral femoral condyle (method 1), the highest point of the intercondylar notch and outer margins of the lateral wall of the intercondylar notch (method 2), and the lowest point of the intercondylar notch and outer margins of the lateral femoral condyle (method 3). For tibial tunnel assessments, rectangular reference frames with the cortical outline at the articular surface of the tibia (method A) and the cortical outline of the proximal tibia (method B) were used. For both femoral and tibial assessments, the tunnel positions at 5°, 10°, and 15° of rotation of the 3D model were compared with that at a neutral position. RESULTS: The values measured by methods 1 and 3 showed significant differences at greater than 5° of rotation compared with the value at the neutral position, whereas method 2 showed relatively consistent results. However, the values measured with both methods A and B showed significant differences at greater than 5° of rotation compared with the value at the neutral position. CONCLUSION: The tunnel position on 3D-CT images was significantly influenced by rotation during measurements. For femoral tunnel position, measurement with a reference frame using the lateral wall of the intercondylar notch (method 2) was the least affected by rotation, with relatively consistent results. CLINICAL RELEVANCE: This study demonstrates that measurement using the lateral wall of the intercondylar notch might be a consistent and reliable method for evaluating the ACL femoral tunnel position considering the effect of 3D-CT image rotation during measurements. However, both methods to measure tibial tunnel position described in this study were similarly affected by rotation.
format Online
Article
Text
id pubmed-6902393
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-69023932019-12-13 Do Rotation and Measurement Methods Affect Reliability of Anterior Cruciate Ligament Tunnel Position on 3D Reconstructed Computed Tomography? Moon, Hyun-Soo Choi, Chong-Hyuk Jung, Min Lee, Dae-Young Chang, Hsienhao Kim, Sung-Hwan Orthop J Sports Med Article BACKGROUND: The literature has seldom investigated the anterior cruciate ligament (ACL) tunnel position while considering the effect of rotation of 3-dimensional computed tomography (3D-CT) images during measurements. HYPOTHESIS: We hypothesized that (1) measurement of the ACL tunnel position in the femur and tibia through use of 3D-CT is considerably influenced by rotation of the 3D model and (2) there exists a reliable measurement method for ACL tunnel position least affected by rotation. STUDY DESIGN: Controlled laboratory study. METHODS: The 3D-CT images of 30 randomly selected patients who underwent single-bundle ACL reconstruction were retrospectively reviewed. For femoral tunnel assessments, rectangular reference frames were used that involved the highest point of the intercondylar notch and outer margins of the lateral femoral condyle (method 1), the highest point of the intercondylar notch and outer margins of the lateral wall of the intercondylar notch (method 2), and the lowest point of the intercondylar notch and outer margins of the lateral femoral condyle (method 3). For tibial tunnel assessments, rectangular reference frames with the cortical outline at the articular surface of the tibia (method A) and the cortical outline of the proximal tibia (method B) were used. For both femoral and tibial assessments, the tunnel positions at 5°, 10°, and 15° of rotation of the 3D model were compared with that at a neutral position. RESULTS: The values measured by methods 1 and 3 showed significant differences at greater than 5° of rotation compared with the value at the neutral position, whereas method 2 showed relatively consistent results. However, the values measured with both methods A and B showed significant differences at greater than 5° of rotation compared with the value at the neutral position. CONCLUSION: The tunnel position on 3D-CT images was significantly influenced by rotation during measurements. For femoral tunnel position, measurement with a reference frame using the lateral wall of the intercondylar notch (method 2) was the least affected by rotation, with relatively consistent results. CLINICAL RELEVANCE: This study demonstrates that measurement using the lateral wall of the intercondylar notch might be a consistent and reliable method for evaluating the ACL femoral tunnel position considering the effect of 3D-CT image rotation during measurements. However, both methods to measure tibial tunnel position described in this study were similarly affected by rotation. SAGE Publications 2019-12-09 /pmc/articles/PMC6902393/ /pubmed/31840029 http://dx.doi.org/10.1177/2325967119885882 Text en © The Author(s) 2019 http://creativecommons.org/licenses/by-nc-nd/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (http://www.creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Moon, Hyun-Soo
Choi, Chong-Hyuk
Jung, Min
Lee, Dae-Young
Chang, Hsienhao
Kim, Sung-Hwan
Do Rotation and Measurement Methods Affect Reliability of Anterior Cruciate Ligament Tunnel Position on 3D Reconstructed Computed Tomography?
title Do Rotation and Measurement Methods Affect Reliability of Anterior Cruciate Ligament Tunnel Position on 3D Reconstructed Computed Tomography?
title_full Do Rotation and Measurement Methods Affect Reliability of Anterior Cruciate Ligament Tunnel Position on 3D Reconstructed Computed Tomography?
title_fullStr Do Rotation and Measurement Methods Affect Reliability of Anterior Cruciate Ligament Tunnel Position on 3D Reconstructed Computed Tomography?
title_full_unstemmed Do Rotation and Measurement Methods Affect Reliability of Anterior Cruciate Ligament Tunnel Position on 3D Reconstructed Computed Tomography?
title_short Do Rotation and Measurement Methods Affect Reliability of Anterior Cruciate Ligament Tunnel Position on 3D Reconstructed Computed Tomography?
title_sort do rotation and measurement methods affect reliability of anterior cruciate ligament tunnel position on 3d reconstructed computed tomography?
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6902393/
https://www.ncbi.nlm.nih.gov/pubmed/31840029
http://dx.doi.org/10.1177/2325967119885882
work_keys_str_mv AT moonhyunsoo dorotationandmeasurementmethodsaffectreliabilityofanteriorcruciateligamenttunnelpositionon3dreconstructedcomputedtomography
AT choichonghyuk dorotationandmeasurementmethodsaffectreliabilityofanteriorcruciateligamenttunnelpositionon3dreconstructedcomputedtomography
AT jungmin dorotationandmeasurementmethodsaffectreliabilityofanteriorcruciateligamenttunnelpositionon3dreconstructedcomputedtomography
AT leedaeyoung dorotationandmeasurementmethodsaffectreliabilityofanteriorcruciateligamenttunnelpositionon3dreconstructedcomputedtomography
AT changhsienhao dorotationandmeasurementmethodsaffectreliabilityofanteriorcruciateligamenttunnelpositionon3dreconstructedcomputedtomography
AT kimsunghwan dorotationandmeasurementmethodsaffectreliabilityofanteriorcruciateligamenttunnelpositionon3dreconstructedcomputedtomography