Cargando…
Competency in home body fat monitoring by portable devices based on bioelectrical impedance analysis: A pilot study
INTRODUCTION: With the advancement of bioelectrical impedance analysis method, body fat can be estimated with portable devices at home. These devices are popular in home body fat monitoring (HBFM). However, improper use of the device may provide erroneous result. AIM: This study aimed to find out th...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6905293/ https://www.ncbi.nlm.nih.gov/pubmed/31867387 http://dx.doi.org/10.4103/jehp.jehp_358_18 |
_version_ | 1783478140844113920 |
---|---|
author | Mondal, Himel Mondal, Shaikat Baidya, Chayan |
author_facet | Mondal, Himel Mondal, Shaikat Baidya, Chayan |
author_sort | Mondal, Himel |
collection | PubMed |
description | INTRODUCTION: With the advancement of bioelectrical impedance analysis method, body fat can be estimated with portable devices at home. These devices are popular in home body fat monitoring (HBFM). However, improper use of the device may provide erroneous result. AIM: This study aimed to find out the level of competency of the operator in HBFM. MATERIALS AND METHODS: A cross-sectional survey was conducted with 34 individuals (males = 11, females = 23) during March–December, 2017. A pretested questionnaire was used to collect information by expert interviewer. Data were collected about premeasurement precautions, steps followed in body fat measurement proper, and postmeasurement action. Survey data were expressed in mean, standard deviation, and percentage and statistically tested by unpaired t-test and Chi-square test according to necessity with α =0.05. Analyses were done in GraphPad Prism 6.01. RESULTS: Premeasurement precautions for maintaining proper hydration level were not followed by majority of the participants. Avoidance of exercise in preceding 12 h was not followed by 94.12% (χ(2) = 26.47, P < 0.0001), voiding bladder before the measurement was not followed by 88.24% (χ(2) = 19.88, P < 0.0001), and avoidance of diuretics (e.g., chocolate, caffeine) was not practiced by 82.35% (χ(2) = 14.24, P = 0.0002). Prescribed steps for measurement proper were followed by majority of the operators. However, 61.76% (χ(2) = 1.88, P = 0.17) forgot to keep log of the readings. CONCLUSION: Clinicians, fitness instructors, and nutritionists should emphasize on premeasurement factors for educating their clients for HBFM. This would help proper tracking of body fat level. |
format | Online Article Text |
id | pubmed-6905293 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-69052932019-12-20 Competency in home body fat monitoring by portable devices based on bioelectrical impedance analysis: A pilot study Mondal, Himel Mondal, Shaikat Baidya, Chayan J Educ Health Promot Original Article INTRODUCTION: With the advancement of bioelectrical impedance analysis method, body fat can be estimated with portable devices at home. These devices are popular in home body fat monitoring (HBFM). However, improper use of the device may provide erroneous result. AIM: This study aimed to find out the level of competency of the operator in HBFM. MATERIALS AND METHODS: A cross-sectional survey was conducted with 34 individuals (males = 11, females = 23) during March–December, 2017. A pretested questionnaire was used to collect information by expert interviewer. Data were collected about premeasurement precautions, steps followed in body fat measurement proper, and postmeasurement action. Survey data were expressed in mean, standard deviation, and percentage and statistically tested by unpaired t-test and Chi-square test according to necessity with α =0.05. Analyses were done in GraphPad Prism 6.01. RESULTS: Premeasurement precautions for maintaining proper hydration level were not followed by majority of the participants. Avoidance of exercise in preceding 12 h was not followed by 94.12% (χ(2) = 26.47, P < 0.0001), voiding bladder before the measurement was not followed by 88.24% (χ(2) = 19.88, P < 0.0001), and avoidance of diuretics (e.g., chocolate, caffeine) was not practiced by 82.35% (χ(2) = 14.24, P = 0.0002). Prescribed steps for measurement proper were followed by majority of the operators. However, 61.76% (χ(2) = 1.88, P = 0.17) forgot to keep log of the readings. CONCLUSION: Clinicians, fitness instructors, and nutritionists should emphasize on premeasurement factors for educating their clients for HBFM. This would help proper tracking of body fat level. Wolters Kluwer - Medknow 2019-11-29 /pmc/articles/PMC6905293/ /pubmed/31867387 http://dx.doi.org/10.4103/jehp.jehp_358_18 Text en Copyright: © 2019 Journal of Education and Health Promotion http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Mondal, Himel Mondal, Shaikat Baidya, Chayan Competency in home body fat monitoring by portable devices based on bioelectrical impedance analysis: A pilot study |
title | Competency in home body fat monitoring by portable devices based on bioelectrical impedance analysis: A pilot study |
title_full | Competency in home body fat monitoring by portable devices based on bioelectrical impedance analysis: A pilot study |
title_fullStr | Competency in home body fat monitoring by portable devices based on bioelectrical impedance analysis: A pilot study |
title_full_unstemmed | Competency in home body fat monitoring by portable devices based on bioelectrical impedance analysis: A pilot study |
title_short | Competency in home body fat monitoring by portable devices based on bioelectrical impedance analysis: A pilot study |
title_sort | competency in home body fat monitoring by portable devices based on bioelectrical impedance analysis: a pilot study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6905293/ https://www.ncbi.nlm.nih.gov/pubmed/31867387 http://dx.doi.org/10.4103/jehp.jehp_358_18 |
work_keys_str_mv | AT mondalhimel competencyinhomebodyfatmonitoringbyportabledevicesbasedonbioelectricalimpedanceanalysisapilotstudy AT mondalshaikat competencyinhomebodyfatmonitoringbyportabledevicesbasedonbioelectricalimpedanceanalysisapilotstudy AT baidyachayan competencyinhomebodyfatmonitoringbyportabledevicesbasedonbioelectricalimpedanceanalysisapilotstudy |