Cargando…
Near Real-Time Implementation of An Adaptive Seismocardiography – ECG Multimodal Framework for Cardiac Gating
Objective: Accurate gating for data acquisition of computed tomography (CT) is crucial to obtaining high quality images for diagnosing cardiovascular diseases. To illustrate the feasibility of an optimized cardiac gating strategy, we present a near real-time implementation based on fusing seismocard...
Formato: | Online Artículo Texto |
---|---|
Lenguaje: | English |
Publicado: |
IEEE
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6906082/ https://www.ncbi.nlm.nih.gov/pubmed/32309054 http://dx.doi.org/10.1109/JTEHM.2019.2923353 |
_version_ | 1783478279380926464 |
---|---|
collection | PubMed |
description | Objective: Accurate gating for data acquisition of computed tomography (CT) is crucial to obtaining high quality images for diagnosing cardiovascular diseases. To illustrate the feasibility of an optimized cardiac gating strategy, we present a near real-time implementation based on fusing seismocardiography (SCG) and ECG. Methods: The implementation was achieved via integrating commercial hardware and software platforms. Testing was performed on five healthy subjects (age: 24–27; m/f: 4/1) and three cardiac patients (age: 41–71; m/f: 2/1), and compared with baseline quiescence derived from echocardiography. Results: The average latency introduced by computerized processing was 5.1 ms, well within a 100 ms tolerance bounded by data accumulation time for quiescence prediction. The average prediction error associated with conventional ECG-only versus SCG-ECG-based method over all subjects were 59.58 ms and 27.24 ms, respectively. Discussion: The results demonstrate that the multimodal framework can achieve improved quiescence prediction accuracy over the ECG-only-based method in near real-time. |
format | Online Article Text |
id | pubmed-6906082 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | IEEE |
record_format | MEDLINE/PubMed |
spelling | pubmed-69060822020-04-17 Near Real-Time Implementation of An Adaptive Seismocardiography – ECG Multimodal Framework for Cardiac Gating IEEE J Transl Eng Health Med Article Objective: Accurate gating for data acquisition of computed tomography (CT) is crucial to obtaining high quality images for diagnosing cardiovascular diseases. To illustrate the feasibility of an optimized cardiac gating strategy, we present a near real-time implementation based on fusing seismocardiography (SCG) and ECG. Methods: The implementation was achieved via integrating commercial hardware and software platforms. Testing was performed on five healthy subjects (age: 24–27; m/f: 4/1) and three cardiac patients (age: 41–71; m/f: 2/1), and compared with baseline quiescence derived from echocardiography. Results: The average latency introduced by computerized processing was 5.1 ms, well within a 100 ms tolerance bounded by data accumulation time for quiescence prediction. The average prediction error associated with conventional ECG-only versus SCG-ECG-based method over all subjects were 59.58 ms and 27.24 ms, respectively. Discussion: The results demonstrate that the multimodal framework can achieve improved quiescence prediction accuracy over the ECG-only-based method in near real-time. IEEE 2019-09-13 /pmc/articles/PMC6906082/ /pubmed/32309054 http://dx.doi.org/10.1109/JTEHM.2019.2923353 Text en https://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Near Real-Time Implementation of An Adaptive Seismocardiography – ECG Multimodal Framework for Cardiac Gating |
title | Near Real-Time Implementation of An Adaptive Seismocardiography – ECG Multimodal Framework for Cardiac Gating |
title_full | Near Real-Time Implementation of An Adaptive Seismocardiography – ECG Multimodal Framework for Cardiac Gating |
title_fullStr | Near Real-Time Implementation of An Adaptive Seismocardiography – ECG Multimodal Framework for Cardiac Gating |
title_full_unstemmed | Near Real-Time Implementation of An Adaptive Seismocardiography – ECG Multimodal Framework for Cardiac Gating |
title_short | Near Real-Time Implementation of An Adaptive Seismocardiography – ECG Multimodal Framework for Cardiac Gating |
title_sort | near real-time implementation of an adaptive seismocardiography – ecg multimodal framework for cardiac gating |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6906082/ https://www.ncbi.nlm.nih.gov/pubmed/32309054 http://dx.doi.org/10.1109/JTEHM.2019.2923353 |
work_keys_str_mv | AT nearrealtimeimplementationofanadaptiveseismocardiographyecgmultimodalframeworkforcardiacgating AT nearrealtimeimplementationofanadaptiveseismocardiographyecgmultimodalframeworkforcardiacgating AT nearrealtimeimplementationofanadaptiveseismocardiographyecgmultimodalframeworkforcardiacgating |