Cargando…
Sample Size Requirements of Glaucoma Clinical Trials When Using Combined Optical Coherence Tomography and Visual Field Endpoints
Glaucoma clinical trials using visual field (VF) endpoints currently require large sample sizes because of the slowly-progressive nature of this disease. We sought to examine whether the combined use of VF testing and non-invasive optical coherence tomography (OCT) imaging of the neuroretinal tissue...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6906445/ https://www.ncbi.nlm.nih.gov/pubmed/31827169 http://dx.doi.org/10.1038/s41598-019-55345-x |
_version_ | 1783478346518102016 |
---|---|
author | Wu, Zhichao Medeiros, Felipe A. |
author_facet | Wu, Zhichao Medeiros, Felipe A. |
author_sort | Wu, Zhichao |
collection | PubMed |
description | Glaucoma clinical trials using visual field (VF) endpoints currently require large sample sizes because of the slowly-progressive nature of this disease. We sought to examine whether the combined use of VF testing and non-invasive optical coherence tomography (OCT) imaging of the neuroretinal tissue could improve the feasibility of such trials. To examine this, we included 192 eyes of 121 glaucoma participants seen at ≥5 visits over a 2-year period to extract real-world estimates of the rates of change and variability of VF and OCT imaging measurements for computer simulations to obtain sample size estimates. We observed that the combined use of VF and OCT endpoints led to a 31–33% reduction in sample size requirements compared to using VF endpoints alone for various treatment effect sizes. For example, 189 participants would be required per group to detect a 30% treatment effect with 90% power with combined VF and OCT endpoints, whilst 276 and 285 participants would be required when using VF and OCT endpoints alone respectively. The combined use of OCT and VF endpoints thus has the potential to effectively improve the feasibility of future glaucoma clinical trials. |
format | Online Article Text |
id | pubmed-6906445 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-69064452019-12-13 Sample Size Requirements of Glaucoma Clinical Trials When Using Combined Optical Coherence Tomography and Visual Field Endpoints Wu, Zhichao Medeiros, Felipe A. Sci Rep Article Glaucoma clinical trials using visual field (VF) endpoints currently require large sample sizes because of the slowly-progressive nature of this disease. We sought to examine whether the combined use of VF testing and non-invasive optical coherence tomography (OCT) imaging of the neuroretinal tissue could improve the feasibility of such trials. To examine this, we included 192 eyes of 121 glaucoma participants seen at ≥5 visits over a 2-year period to extract real-world estimates of the rates of change and variability of VF and OCT imaging measurements for computer simulations to obtain sample size estimates. We observed that the combined use of VF and OCT endpoints led to a 31–33% reduction in sample size requirements compared to using VF endpoints alone for various treatment effect sizes. For example, 189 participants would be required per group to detect a 30% treatment effect with 90% power with combined VF and OCT endpoints, whilst 276 and 285 participants would be required when using VF and OCT endpoints alone respectively. The combined use of OCT and VF endpoints thus has the potential to effectively improve the feasibility of future glaucoma clinical trials. Nature Publishing Group UK 2019-12-11 /pmc/articles/PMC6906445/ /pubmed/31827169 http://dx.doi.org/10.1038/s41598-019-55345-x Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Wu, Zhichao Medeiros, Felipe A. Sample Size Requirements of Glaucoma Clinical Trials When Using Combined Optical Coherence Tomography and Visual Field Endpoints |
title | Sample Size Requirements of Glaucoma Clinical Trials When Using Combined Optical Coherence Tomography and Visual Field Endpoints |
title_full | Sample Size Requirements of Glaucoma Clinical Trials When Using Combined Optical Coherence Tomography and Visual Field Endpoints |
title_fullStr | Sample Size Requirements of Glaucoma Clinical Trials When Using Combined Optical Coherence Tomography and Visual Field Endpoints |
title_full_unstemmed | Sample Size Requirements of Glaucoma Clinical Trials When Using Combined Optical Coherence Tomography and Visual Field Endpoints |
title_short | Sample Size Requirements of Glaucoma Clinical Trials When Using Combined Optical Coherence Tomography and Visual Field Endpoints |
title_sort | sample size requirements of glaucoma clinical trials when using combined optical coherence tomography and visual field endpoints |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6906445/ https://www.ncbi.nlm.nih.gov/pubmed/31827169 http://dx.doi.org/10.1038/s41598-019-55345-x |
work_keys_str_mv | AT wuzhichao samplesizerequirementsofglaucomaclinicaltrialswhenusingcombinedopticalcoherencetomographyandvisualfieldendpoints AT medeirosfelipea samplesizerequirementsofglaucomaclinicaltrialswhenusingcombinedopticalcoherencetomographyandvisualfieldendpoints |