Cargando…

Simultaneous Assay of Dexchlorpheniramine Maleate, Betamethasone, and Sodium Benzoate in Syrup by a Reliable and Robust HPLC Method

The simultaneous determination of betamethasone, dexchlorpheniramine maleate, and sodium benzoate in pharmaceutical syrup was done by using a simple validated HPLC method. The chromatographic separation of the three analytes was done in a C18 column maintained at 25°C, using a mixture of acetonitril...

Descripción completa

Detalles Bibliográficos
Autores principales: Le, Dinh Chi, Ngo, Thi Duyen, Hoa Le, Thi Huong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6907040/
https://www.ncbi.nlm.nih.gov/pubmed/31871819
http://dx.doi.org/10.1155/2019/2952075
Descripción
Sumario:The simultaneous determination of betamethasone, dexchlorpheniramine maleate, and sodium benzoate in pharmaceutical syrup was done by using a simple validated HPLC method. The chromatographic separation of the three analytes was done in a C18 column maintained at 25°C, using a mixture of acetonitrile and 0.02 M phosphate buffer solution pH 2.70 (35 : 65, v : v) as mobile phase. The isocratic elution was chosen with total flow rate of mobile phase maintained at 1.0 mL per minute. The analytes were detected by a UV-Vis detector set at 254 nm. Injection volume was set at 50 μl. The method was fully validated in terms of specificity, linearity, precision, accuracy, and robustness according to requirements of current guidelines and was proven to be suitable for the intended application.