Cargando…

Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance

BACKGROUND: Arterial pulse wave velocity (PWV) is associated with increased mortality in aging and disease. Several studies have shown the accuracy of applanation tonometry carotid-femoral PWV (Cf-PWV) and the relevance of evaluating central aorta stiffness using 2D cardiovascular magnetic resonance...

Descripción completa

Detalles Bibliográficos
Autores principales: Houriez--Gombaud-Saintonge, Sophia, Mousseaux, Elie, Bargiotas, Ioannis, De Cesare, Alain, Dietenbeck, Thomas, Bouaou, Kevin, Redheuil, Alban, Soulat, Gilles, Giron, Alain, Gencer, Umit, Craiem, Damian, Messas, Emmanuel, Bollache, Emilie, Chenoune, Yasmina, Kachenoura, Nadjia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6907267/
https://www.ncbi.nlm.nih.gov/pubmed/31829235
http://dx.doi.org/10.1186/s12968-019-0584-x
_version_ 1783478517187477504
author Houriez--Gombaud-Saintonge, Sophia
Mousseaux, Elie
Bargiotas, Ioannis
De Cesare, Alain
Dietenbeck, Thomas
Bouaou, Kevin
Redheuil, Alban
Soulat, Gilles
Giron, Alain
Gencer, Umit
Craiem, Damian
Messas, Emmanuel
Bollache, Emilie
Chenoune, Yasmina
Kachenoura, Nadjia
author_facet Houriez--Gombaud-Saintonge, Sophia
Mousseaux, Elie
Bargiotas, Ioannis
De Cesare, Alain
Dietenbeck, Thomas
Bouaou, Kevin
Redheuil, Alban
Soulat, Gilles
Giron, Alain
Gencer, Umit
Craiem, Damian
Messas, Emmanuel
Bollache, Emilie
Chenoune, Yasmina
Kachenoura, Nadjia
author_sort Houriez--Gombaud-Saintonge, Sophia
collection PubMed
description BACKGROUND: Arterial pulse wave velocity (PWV) is associated with increased mortality in aging and disease. Several studies have shown the accuracy of applanation tonometry carotid-femoral PWV (Cf-PWV) and the relevance of evaluating central aorta stiffness using 2D cardiovascular magnetic resonance (CMR) to estimate PWV, and aortic distensibility-derived PWV through the theoretical Bramwell-Hill model (BH-PWV). Our aim was to compare various methods of aortic PWV (aoPWV) estimation from 4D flow CMR, in terms of associations with age, Cf-PWV, BH-PWV and left ventricular (LV) mass-to-volume ratio while evaluating inter-observer reproducibility and robustness to temporal resolution. METHODS: We studied 47 healthy subjects (49.5 ± 18 years) who underwent Cf-PWV and CMR including aortic 4D flow CMR as well as 2D cine SSFP for BH-PWV and LV mass-to-volume ratio estimation. The aorta was semi-automatically segmented from 4D flow data, and mean velocity waveforms were estimated in 25 planes perpendicular to the aortic centerline. 4D flow CMR aoPWV was calculated: using velocity curves at two locations, namely ascending aorta (AAo) and distal descending aorta (DAo) aorta (S1, 2D-like strategy), or using all velocity curves along the entire aortic centreline (3D-like strategies) with iterative transit time (TT) estimates (S2) or a plane fitting of velocity curves systolic upslope (S3). For S1 and S2, TT was calculated using three approaches: cross-correlation (TTc), wavelets (TTw) and Fourier transforms (TTf). Intra-class correlation coefficients (ICC) and Bland-Altman biases (BA) were used to evaluate inter-observer reproducibility and effect of lower temporal resolution. RESULTS: 4D flow CMR aoPWV estimates were significantly (p < 0.05) correlated to the CMR-independent Cf-PWV, BH-PWV, age and LV mass-to-volume ratio, with the strongest correlations for the 3D-like strategy using wavelets TT (S2-TTw) (R = 0.62, 0.65, 0.77 and 0.52, respectively, all p < 0.001). S2-TTw was also highly reproducible (ICC = 0.99, BA = 0.09 m/s) and robust to lower temporal resolution (ICC = 0.97, BA = 0.15 m/s). CONCLUSIONS: Reproducible 4D flow CMR aoPWV estimates can be obtained using full 3D aortic coverage. Such 4D flow CMR stiffness measures were significantly associated with Cf-PWV, BH-PWV, age and LV mass-to-volume ratio, with a slight superiority of the 3D strategy using wavelets transit time (S2-TTw).
format Online
Article
Text
id pubmed-6907267
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-69072672019-12-20 Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance Houriez--Gombaud-Saintonge, Sophia Mousseaux, Elie Bargiotas, Ioannis De Cesare, Alain Dietenbeck, Thomas Bouaou, Kevin Redheuil, Alban Soulat, Gilles Giron, Alain Gencer, Umit Craiem, Damian Messas, Emmanuel Bollache, Emilie Chenoune, Yasmina Kachenoura, Nadjia J Cardiovasc Magn Reson Research BACKGROUND: Arterial pulse wave velocity (PWV) is associated with increased mortality in aging and disease. Several studies have shown the accuracy of applanation tonometry carotid-femoral PWV (Cf-PWV) and the relevance of evaluating central aorta stiffness using 2D cardiovascular magnetic resonance (CMR) to estimate PWV, and aortic distensibility-derived PWV through the theoretical Bramwell-Hill model (BH-PWV). Our aim was to compare various methods of aortic PWV (aoPWV) estimation from 4D flow CMR, in terms of associations with age, Cf-PWV, BH-PWV and left ventricular (LV) mass-to-volume ratio while evaluating inter-observer reproducibility and robustness to temporal resolution. METHODS: We studied 47 healthy subjects (49.5 ± 18 years) who underwent Cf-PWV and CMR including aortic 4D flow CMR as well as 2D cine SSFP for BH-PWV and LV mass-to-volume ratio estimation. The aorta was semi-automatically segmented from 4D flow data, and mean velocity waveforms were estimated in 25 planes perpendicular to the aortic centerline. 4D flow CMR aoPWV was calculated: using velocity curves at two locations, namely ascending aorta (AAo) and distal descending aorta (DAo) aorta (S1, 2D-like strategy), or using all velocity curves along the entire aortic centreline (3D-like strategies) with iterative transit time (TT) estimates (S2) or a plane fitting of velocity curves systolic upslope (S3). For S1 and S2, TT was calculated using three approaches: cross-correlation (TTc), wavelets (TTw) and Fourier transforms (TTf). Intra-class correlation coefficients (ICC) and Bland-Altman biases (BA) were used to evaluate inter-observer reproducibility and effect of lower temporal resolution. RESULTS: 4D flow CMR aoPWV estimates were significantly (p < 0.05) correlated to the CMR-independent Cf-PWV, BH-PWV, age and LV mass-to-volume ratio, with the strongest correlations for the 3D-like strategy using wavelets TT (S2-TTw) (R = 0.62, 0.65, 0.77 and 0.52, respectively, all p < 0.001). S2-TTw was also highly reproducible (ICC = 0.99, BA = 0.09 m/s) and robust to lower temporal resolution (ICC = 0.97, BA = 0.15 m/s). CONCLUSIONS: Reproducible 4D flow CMR aoPWV estimates can be obtained using full 3D aortic coverage. Such 4D flow CMR stiffness measures were significantly associated with Cf-PWV, BH-PWV, age and LV mass-to-volume ratio, with a slight superiority of the 3D strategy using wavelets transit time (S2-TTw). BioMed Central 2019-12-12 /pmc/articles/PMC6907267/ /pubmed/31829235 http://dx.doi.org/10.1186/s12968-019-0584-x Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Houriez--Gombaud-Saintonge, Sophia
Mousseaux, Elie
Bargiotas, Ioannis
De Cesare, Alain
Dietenbeck, Thomas
Bouaou, Kevin
Redheuil, Alban
Soulat, Gilles
Giron, Alain
Gencer, Umit
Craiem, Damian
Messas, Emmanuel
Bollache, Emilie
Chenoune, Yasmina
Kachenoura, Nadjia
Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
title Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
title_full Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
title_fullStr Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
title_full_unstemmed Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
title_short Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
title_sort comparison of different methods for the estimation of aortic pulse wave velocity from 4d flow cardiovascular magnetic resonance
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6907267/
https://www.ncbi.nlm.nih.gov/pubmed/31829235
http://dx.doi.org/10.1186/s12968-019-0584-x
work_keys_str_mv AT houriezgombaudsaintongesophia comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT mousseauxelie comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT bargiotasioannis comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT decesarealain comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT dietenbeckthomas comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT bouaoukevin comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT redheuilalban comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT soulatgilles comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT gironalain comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT gencerumit comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT craiemdamian comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT messasemmanuel comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT bollacheemilie comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT chenouneyasmina comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance
AT kachenouranadjia comparisonofdifferentmethodsfortheestimationofaorticpulsewavevelocityfrom4dflowcardiovascularmagneticresonance