Cargando…

Saline-push improves rubidium-82 PET image quality

INTRODUCTION: Rubidium-82 ((82)Rb) PET is used widely for myocardial perfusion imaging. The purpose of this study was to investigate if an additional saline-push following the (82)Rb elution improves PET image quality. METHODS: (82)Rb PET scans were acquired with and without 26 mL saline-push in six...

Descripción completa

Detalles Bibliográficos
Autores principales: Renaud, Jennifer M., Wu, Kai Yi, Gardner, Kimberly, Aung, May, Beanlands, Rob S. B., deKemp, Robert A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6908549/
https://www.ncbi.nlm.nih.gov/pubmed/29589206
http://dx.doi.org/10.1007/s12350-018-1261-4
_version_ 1783478748081815552
author Renaud, Jennifer M.
Wu, Kai Yi
Gardner, Kimberly
Aung, May
Beanlands, Rob S. B.
deKemp, Robert A.
author_facet Renaud, Jennifer M.
Wu, Kai Yi
Gardner, Kimberly
Aung, May
Beanlands, Rob S. B.
deKemp, Robert A.
author_sort Renaud, Jennifer M.
collection PubMed
description INTRODUCTION: Rubidium-82 ((82)Rb) PET is used widely for myocardial perfusion imaging. The purpose of this study was to investigate if an additional saline-push following the (82)Rb elution improves PET image quality. METHODS: (82)Rb PET scans were acquired with and without 26 mL saline-push in six patients as part of a clinical quality improvement program. Dynamic images were analyzed to measure the total activity delivered to the superior vena cava (SVC) and retained in the left ventricle (LV) myocardium. Tracer uptake images were used to measure blood background coefficient-of-variation (COV), myocardium-to-blood signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) to assess image quality. RESULTS: Similar eluted activity was measured with/without the saline-push (830 vs 795 MBq; P = 0.24). The activity delivered to the heart and retained in the myocardium was consistently increased more than twofold (SVC: + 114% and LV: + 104%; P < 0.001) with the saline-push. Image quality was improved in all patients, with lower background noise (COV: − 19%), higher SNR (+ 24%) and CNR (+ 27%) (all P ≤ 0.01). CONCLUSIONS: The saline-push used to flush (82)Rb activity out of the infuser tubing, patient injection and intravenous access lines consistently increased the activity delivered to the heart by twofold. This technique is recommended to maximize image quality with (82)Rb PET. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s12350-018-1261-4) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6908549
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-69085492019-12-26 Saline-push improves rubidium-82 PET image quality Renaud, Jennifer M. Wu, Kai Yi Gardner, Kimberly Aung, May Beanlands, Rob S. B. deKemp, Robert A. J Nucl Cardiol Brief Report INTRODUCTION: Rubidium-82 ((82)Rb) PET is used widely for myocardial perfusion imaging. The purpose of this study was to investigate if an additional saline-push following the (82)Rb elution improves PET image quality. METHODS: (82)Rb PET scans were acquired with and without 26 mL saline-push in six patients as part of a clinical quality improvement program. Dynamic images were analyzed to measure the total activity delivered to the superior vena cava (SVC) and retained in the left ventricle (LV) myocardium. Tracer uptake images were used to measure blood background coefficient-of-variation (COV), myocardium-to-blood signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) to assess image quality. RESULTS: Similar eluted activity was measured with/without the saline-push (830 vs 795 MBq; P = 0.24). The activity delivered to the heart and retained in the myocardium was consistently increased more than twofold (SVC: + 114% and LV: + 104%; P < 0.001) with the saline-push. Image quality was improved in all patients, with lower background noise (COV: − 19%), higher SNR (+ 24%) and CNR (+ 27%) (all P ≤ 0.01). CONCLUSIONS: The saline-push used to flush (82)Rb activity out of the infuser tubing, patient injection and intravenous access lines consistently increased the activity delivered to the heart by twofold. This technique is recommended to maximize image quality with (82)Rb PET. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s12350-018-1261-4) contains supplementary material, which is available to authorized users. Springer International Publishing 2018-03-27 2019 /pmc/articles/PMC6908549/ /pubmed/29589206 http://dx.doi.org/10.1007/s12350-018-1261-4 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Brief Report
Renaud, Jennifer M.
Wu, Kai Yi
Gardner, Kimberly
Aung, May
Beanlands, Rob S. B.
deKemp, Robert A.
Saline-push improves rubidium-82 PET image quality
title Saline-push improves rubidium-82 PET image quality
title_full Saline-push improves rubidium-82 PET image quality
title_fullStr Saline-push improves rubidium-82 PET image quality
title_full_unstemmed Saline-push improves rubidium-82 PET image quality
title_short Saline-push improves rubidium-82 PET image quality
title_sort saline-push improves rubidium-82 pet image quality
topic Brief Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6908549/
https://www.ncbi.nlm.nih.gov/pubmed/29589206
http://dx.doi.org/10.1007/s12350-018-1261-4
work_keys_str_mv AT renaudjenniferm salinepushimprovesrubidium82petimagequality
AT wukaiyi salinepushimprovesrubidium82petimagequality
AT gardnerkimberly salinepushimprovesrubidium82petimagequality
AT aungmay salinepushimprovesrubidium82petimagequality
AT beanlandsrobsb salinepushimprovesrubidium82petimagequality
AT dekemproberta salinepushimprovesrubidium82petimagequality