Selection of prescription isodose line for brain metastases treated with volumetric modulated arc radiotherapy

PURPOSE: To exploit the optimal prescription isodose line (IDL) for brain metastases treated with volumetric modulated arc radiotherapy (VMAT) as there is no consensus on the selection of IDL with VMAT. METHODS AND MATERIALS: Eighteen patients with 20 brain tumors, who were treated with VMAT, were e...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Yuan, Ma, Pan, Xu, Yingjie, Dai, Jianrong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6909111/
https://www.ncbi.nlm.nih.gov/pubmed/31833642
http://dx.doi.org/10.1002/acm2.12761
_version_ 1783478887049592832
author Xu, Yuan
Ma, Pan
Xu, Yingjie
Dai, Jianrong
author_facet Xu, Yuan
Ma, Pan
Xu, Yingjie
Dai, Jianrong
author_sort Xu, Yuan
collection PubMed
description PURPOSE: To exploit the optimal prescription isodose line (IDL) for brain metastases treated with volumetric modulated arc radiotherapy (VMAT) as there is no consensus on the selection of IDL with VMAT. METHODS AND MATERIALS: Eighteen patients with 20 brain tumors, who were treated with VMAT, were enrolled in this study. For each tumor of every patient, five plans were designed with IDL ranging from 50% to 90% in 10% increments. Different IDLs were obtained through adjusting the constraint parameters during planning optimization. Prescription dose (10 × 5 Gy) were identical for all plans, and the plans were compared in terms of gradient index (GI), conformity Index (CI), V26 Gy/V(PTV), and V32 Gy/V(PTV) in normal brain tissue, which correlate to radiation necrosis. RESULTS: IDL with lowest GI has a median value of 60.0% (ranging from 50% to 80%). Except for one tumor with volume larger than 10 cc, the IDL with lowest GI varies from 50% to 70%, which depends on the shape of PTV, location, and whether the target volume is adjacent to crucial OAR. Moreover, there is no significant difference for CI with varying IDL plans. The average V26 Gy/V(PTV) and V32 Gy/V(PTV) in normal brain tissue 60% IDL plans are 27.3%, 31.7% lower than 90% IDL plans separately (P < 0.05). However, by further decreasing IDL from 60% to 50%, the average V26 Gy/V(PTV) and V32 Gy/V(PTV) may increase comparing with 60% IDL plans (P > 0.05). Furthermore, a lower IDL is found to result in higher mean dose to the target volume (P < 0.05). CONCLUSIONS: Plans using VMAT with PTV smaller than 10 cc tend to be optimal with IDL around 60–70% for lower GI, smaller V26 Gy/V(PTV), V32 Gy/V(PTV) in normal brain tissue, and higher mean dose in tumor comparing with high IDL plans which have potential benefit in reducing risk of radiation necrosis and increasing the local control. However, IDL lower than 60% is not recommended for the disadvantage of increasing V26 Gy/V(PTV) and V32 Gy/V(PTV) in normal brain tissue.
format Online
Article
Text
id pubmed-6909111
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-69091112019-12-20 Selection of prescription isodose line for brain metastases treated with volumetric modulated arc radiotherapy Xu, Yuan Ma, Pan Xu, Yingjie Dai, Jianrong J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: To exploit the optimal prescription isodose line (IDL) for brain metastases treated with volumetric modulated arc radiotherapy (VMAT) as there is no consensus on the selection of IDL with VMAT. METHODS AND MATERIALS: Eighteen patients with 20 brain tumors, who were treated with VMAT, were enrolled in this study. For each tumor of every patient, five plans were designed with IDL ranging from 50% to 90% in 10% increments. Different IDLs were obtained through adjusting the constraint parameters during planning optimization. Prescription dose (10 × 5 Gy) were identical for all plans, and the plans were compared in terms of gradient index (GI), conformity Index (CI), V26 Gy/V(PTV), and V32 Gy/V(PTV) in normal brain tissue, which correlate to radiation necrosis. RESULTS: IDL with lowest GI has a median value of 60.0% (ranging from 50% to 80%). Except for one tumor with volume larger than 10 cc, the IDL with lowest GI varies from 50% to 70%, which depends on the shape of PTV, location, and whether the target volume is adjacent to crucial OAR. Moreover, there is no significant difference for CI with varying IDL plans. The average V26 Gy/V(PTV) and V32 Gy/V(PTV) in normal brain tissue 60% IDL plans are 27.3%, 31.7% lower than 90% IDL plans separately (P < 0.05). However, by further decreasing IDL from 60% to 50%, the average V26 Gy/V(PTV) and V32 Gy/V(PTV) may increase comparing with 60% IDL plans (P > 0.05). Furthermore, a lower IDL is found to result in higher mean dose to the target volume (P < 0.05). CONCLUSIONS: Plans using VMAT with PTV smaller than 10 cc tend to be optimal with IDL around 60–70% for lower GI, smaller V26 Gy/V(PTV), V32 Gy/V(PTV) in normal brain tissue, and higher mean dose in tumor comparing with high IDL plans which have potential benefit in reducing risk of radiation necrosis and increasing the local control. However, IDL lower than 60% is not recommended for the disadvantage of increasing V26 Gy/V(PTV) and V32 Gy/V(PTV) in normal brain tissue. John Wiley and Sons Inc. 2019-12-03 /pmc/articles/PMC6909111/ /pubmed/31833642 http://dx.doi.org/10.1002/acm2.12761 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Xu, Yuan
Ma, Pan
Xu, Yingjie
Dai, Jianrong
Selection of prescription isodose line for brain metastases treated with volumetric modulated arc radiotherapy
title Selection of prescription isodose line for brain metastases treated with volumetric modulated arc radiotherapy
title_full Selection of prescription isodose line for brain metastases treated with volumetric modulated arc radiotherapy
title_fullStr Selection of prescription isodose line for brain metastases treated with volumetric modulated arc radiotherapy
title_full_unstemmed Selection of prescription isodose line for brain metastases treated with volumetric modulated arc radiotherapy
title_short Selection of prescription isodose line for brain metastases treated with volumetric modulated arc radiotherapy
title_sort selection of prescription isodose line for brain metastases treated with volumetric modulated arc radiotherapy
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6909111/
https://www.ncbi.nlm.nih.gov/pubmed/31833642
http://dx.doi.org/10.1002/acm2.12761
work_keys_str_mv AT xuyuan selectionofprescriptionisodoselineforbrainmetastasestreatedwithvolumetricmodulatedarcradiotherapy
AT mapan selectionofprescriptionisodoselineforbrainmetastasestreatedwithvolumetricmodulatedarcradiotherapy
AT xuyingjie selectionofprescriptionisodoselineforbrainmetastasestreatedwithvolumetricmodulatedarcradiotherapy
AT daijianrong selectionofprescriptionisodoselineforbrainmetastasestreatedwithvolumetricmodulatedarcradiotherapy