Structure guided deformable image registration for treatment planning CT and post stereotactic body radiation therapy (SBRT) Primovist(®) (Gd‐EOB‐DTPA) enhanced MRI
The purpose of this study was to assess the performance of structure‐guided deformable image registration (SG‐DIR) relative to rigid registration and DIR using TG‐132 recommendations. This assessment was performed for image registration of treatment planning computed tomography (CT) and magnetic res...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6909124/ https://www.ncbi.nlm.nih.gov/pubmed/31755658 http://dx.doi.org/10.1002/acm2.12773 |
_version_ | 1783478890133454848 |
---|---|
author | Kuznetsova, Svetlana Grendarova, Petra Roy, Soumyajit Sinha, Rishi Thind, Kundan Ploquin, Nicolas |
author_facet | Kuznetsova, Svetlana Grendarova, Petra Roy, Soumyajit Sinha, Rishi Thind, Kundan Ploquin, Nicolas |
author_sort | Kuznetsova, Svetlana |
collection | PubMed |
description | The purpose of this study was to assess the performance of structure‐guided deformable image registration (SG‐DIR) relative to rigid registration and DIR using TG‐132 recommendations. This assessment was performed for image registration of treatment planning computed tomography (CT) and magnetic resonance imaging (MRI) scans with Primovist(®) contrast agent acquired post stereotactic body radiation therapy (SBRT). SBRT treatment planning CT scans and posttreatment Primovist(®) MRI scans were obtained for 14 patients. The liver was delineated on both sets of images and matching anatomical landmarks were chosen by a radiation oncologist. Rigid registration, DIR, and two types of SG‐DIR (using liver contours only; and using liver structures along with anatomical landmarks) were performed for each set of scans. TG‐132 recommended metrics were estimated which included Dice Similarity Coefficient (DSC), Mean Distance to Agreement (MDA), Target Registration Error (TRE), and Jacobian determinant. Statistical analysis was performed using Wilcoxon Signed Rank test. The median (range) DSC for rigid registration was 0.88 (0.77–0.89), 0.89 (0.81–0.93) for DIR, and 0.90 (0.86–0.94) for both types of SG‐DIR tested in this study. The median MDA was 4.8 mm (3.7–6.8 mm) for rigid registration, 3.4 mm (2.4–8.7 mm) for DIR, 3.2 mm (2.0–5.2 mm) for SG‐DIR where liver structures were used to guide the registration, and 2.8 mm (2.1–4.2 mm) for the SG‐DIR where liver structures and anatomical landmarks were used to guide the registration. The median TRE for rigid registration was 7.2 mm (0.5–23 mm), 6.8 mm (0.7–30.7 mm) for DIR, 6.1 mm (1.1–20.5 mm) for the SG‐DIR guided by only the liver structures, and 4.1 mm (0.8–19.7 mm) for SG‐DIR guided by liver contours and anatomical landmarks. The SG‐DIR shows higher liver conformality as per TG‐132 metrics and lowest TRE compared to rigid registration and DIR in Velocity AI software for the purpose of registering treatment planning CT and post‐SBRT MRI for the liver region. It was found that TRE decreases when liver contours and corresponding anatomical landmarks guide SG‐DIR. |
format | Online Article Text |
id | pubmed-6909124 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-69091242019-12-20 Structure guided deformable image registration for treatment planning CT and post stereotactic body radiation therapy (SBRT) Primovist(®) (Gd‐EOB‐DTPA) enhanced MRI Kuznetsova, Svetlana Grendarova, Petra Roy, Soumyajit Sinha, Rishi Thind, Kundan Ploquin, Nicolas J Appl Clin Med Phys Radiation Oncology Physics The purpose of this study was to assess the performance of structure‐guided deformable image registration (SG‐DIR) relative to rigid registration and DIR using TG‐132 recommendations. This assessment was performed for image registration of treatment planning computed tomography (CT) and magnetic resonance imaging (MRI) scans with Primovist(®) contrast agent acquired post stereotactic body radiation therapy (SBRT). SBRT treatment planning CT scans and posttreatment Primovist(®) MRI scans were obtained for 14 patients. The liver was delineated on both sets of images and matching anatomical landmarks were chosen by a radiation oncologist. Rigid registration, DIR, and two types of SG‐DIR (using liver contours only; and using liver structures along with anatomical landmarks) were performed for each set of scans. TG‐132 recommended metrics were estimated which included Dice Similarity Coefficient (DSC), Mean Distance to Agreement (MDA), Target Registration Error (TRE), and Jacobian determinant. Statistical analysis was performed using Wilcoxon Signed Rank test. The median (range) DSC for rigid registration was 0.88 (0.77–0.89), 0.89 (0.81–0.93) for DIR, and 0.90 (0.86–0.94) for both types of SG‐DIR tested in this study. The median MDA was 4.8 mm (3.7–6.8 mm) for rigid registration, 3.4 mm (2.4–8.7 mm) for DIR, 3.2 mm (2.0–5.2 mm) for SG‐DIR where liver structures were used to guide the registration, and 2.8 mm (2.1–4.2 mm) for the SG‐DIR where liver structures and anatomical landmarks were used to guide the registration. The median TRE for rigid registration was 7.2 mm (0.5–23 mm), 6.8 mm (0.7–30.7 mm) for DIR, 6.1 mm (1.1–20.5 mm) for the SG‐DIR guided by only the liver structures, and 4.1 mm (0.8–19.7 mm) for SG‐DIR guided by liver contours and anatomical landmarks. The SG‐DIR shows higher liver conformality as per TG‐132 metrics and lowest TRE compared to rigid registration and DIR in Velocity AI software for the purpose of registering treatment planning CT and post‐SBRT MRI for the liver region. It was found that TRE decreases when liver contours and corresponding anatomical landmarks guide SG‐DIR. John Wiley and Sons Inc. 2019-11-22 /pmc/articles/PMC6909124/ /pubmed/31755658 http://dx.doi.org/10.1002/acm2.12773 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Kuznetsova, Svetlana Grendarova, Petra Roy, Soumyajit Sinha, Rishi Thind, Kundan Ploquin, Nicolas Structure guided deformable image registration for treatment planning CT and post stereotactic body radiation therapy (SBRT) Primovist(®) (Gd‐EOB‐DTPA) enhanced MRI |
title | Structure guided deformable image registration for treatment planning CT and post stereotactic body radiation therapy (SBRT) Primovist(®) (Gd‐EOB‐DTPA) enhanced MRI |
title_full | Structure guided deformable image registration for treatment planning CT and post stereotactic body radiation therapy (SBRT) Primovist(®) (Gd‐EOB‐DTPA) enhanced MRI |
title_fullStr | Structure guided deformable image registration for treatment planning CT and post stereotactic body radiation therapy (SBRT) Primovist(®) (Gd‐EOB‐DTPA) enhanced MRI |
title_full_unstemmed | Structure guided deformable image registration for treatment planning CT and post stereotactic body radiation therapy (SBRT) Primovist(®) (Gd‐EOB‐DTPA) enhanced MRI |
title_short | Structure guided deformable image registration for treatment planning CT and post stereotactic body radiation therapy (SBRT) Primovist(®) (Gd‐EOB‐DTPA) enhanced MRI |
title_sort | structure guided deformable image registration for treatment planning ct and post stereotactic body radiation therapy (sbrt) primovist(®) (gd‐eob‐dtpa) enhanced mri |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6909124/ https://www.ncbi.nlm.nih.gov/pubmed/31755658 http://dx.doi.org/10.1002/acm2.12773 |
work_keys_str_mv | AT kuznetsovasvetlana structureguideddeformableimageregistrationfortreatmentplanningctandpoststereotacticbodyradiationtherapysbrtprimovistgdeobdtpaenhancedmri AT grendarovapetra structureguideddeformableimageregistrationfortreatmentplanningctandpoststereotacticbodyradiationtherapysbrtprimovistgdeobdtpaenhancedmri AT roysoumyajit structureguideddeformableimageregistrationfortreatmentplanningctandpoststereotacticbodyradiationtherapysbrtprimovistgdeobdtpaenhancedmri AT sinharishi structureguideddeformableimageregistrationfortreatmentplanningctandpoststereotacticbodyradiationtherapysbrtprimovistgdeobdtpaenhancedmri AT thindkundan structureguideddeformableimageregistrationfortreatmentplanningctandpoststereotacticbodyradiationtherapysbrtprimovistgdeobdtpaenhancedmri AT ploquinnicolas structureguideddeformableimageregistrationfortreatmentplanningctandpoststereotacticbodyradiationtherapysbrtprimovistgdeobdtpaenhancedmri |