Cargando…
Nitrogen oxide reduction through absorbent solutions containing nitric acid and hydrogen peroxide in hollow fiber membrane modules
Emissions of nitrogen oxides such as NO and NO(2), which are commonly known as NOx, are threats to human existence and cause environmental problems. Mainly, two techniques have been developed to drastically reduce these emissions, which are dry and wet processes. The wet process has several advantag...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6911882/ https://www.ncbi.nlm.nih.gov/pubmed/31872135 http://dx.doi.org/10.1016/j.heliyon.2019.e02987 |
_version_ | 1783479339488116736 |
---|---|
author | Kartohardjono, Sutrasno Merry, Clarissa Rizky, Mohamad Sofwan Pratita, Catharina Candra |
author_facet | Kartohardjono, Sutrasno Merry, Clarissa Rizky, Mohamad Sofwan Pratita, Catharina Candra |
author_sort | Kartohardjono, Sutrasno |
collection | PubMed |
description | Emissions of nitrogen oxides such as NO and NO(2), which are commonly known as NOx, are threats to human existence and cause environmental problems. Mainly, two techniques have been developed to drastically reduce these emissions, which are dry and wet processes. The wet process has several advantages, major identifiable advantages are the adaptability to the flue gas, low operating temperatures and no poisoning and inactivation catalyst. Also, a mixture of hydrogen peroxide and nitric acid are used as absorbents solution for NOx reduction in the wet process. The advantages of using this mixture include the ability to reduce the negative effect of NOx and does not contaminate the scrubbing solution. In addition, nitric acid has an economical advantage in the process considering the fact that it is produced in the process. Finally, it can be conducted at ambient temperature. This study furthermore used a mixture of hydrogen peroxide and nitric acid solutions as an absorbent to reduce NOx in hollow fiber membrane modules. The hydrogen peroxide oxidized HNO(2) to nitric acid, while enhances the oxidation through an autocatalytic reaction. The effects of the feed gas flow rate, hydrogen peroxide concentrations and number of fibers on the NOx reduction, absorbed NOx and flux were varied to study. The experimental results showed that the increase in the feed gas flow rate from 100 to 200 mL/min decreased NOx reduction from about 98 to 94% but increased the absorbed NOx and flux from about 0.13 to 0.255 mmol/h and 0.85–1.63 mmol/m(2).h, respectively The increase in proportion of NO(x) in the feed gas effect was dominant than the increase in absorbed NOx. An increase in hydrogen peroxide concentration from 0.5 to 10 wt.% in the absorbent solutions increased NOx reduction, absorbed NOx and flux from about 94 to 98%, 0.257–0.267 mmol/h and 1.09–1.13 mmol/m(2).h, respectively. Additionally, the H(2)O(2) plays an important role in enhancing HNO(2) oxidation to HNO(3). Furthermore, an increase in the number of fibers from 50 to 150 in the membrane module increased NOx reduction and absorbed NOx from 86 to 97% and 0.23–0.27 mmol/h. Flux decreased from 2.98 to 1.13 mmol/m(2).h due to increment in the gas-liquid contact surface area. |
format | Online Article Text |
id | pubmed-6911882 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-69118822019-12-23 Nitrogen oxide reduction through absorbent solutions containing nitric acid and hydrogen peroxide in hollow fiber membrane modules Kartohardjono, Sutrasno Merry, Clarissa Rizky, Mohamad Sofwan Pratita, Catharina Candra Heliyon Article Emissions of nitrogen oxides such as NO and NO(2), which are commonly known as NOx, are threats to human existence and cause environmental problems. Mainly, two techniques have been developed to drastically reduce these emissions, which are dry and wet processes. The wet process has several advantages, major identifiable advantages are the adaptability to the flue gas, low operating temperatures and no poisoning and inactivation catalyst. Also, a mixture of hydrogen peroxide and nitric acid are used as absorbents solution for NOx reduction in the wet process. The advantages of using this mixture include the ability to reduce the negative effect of NOx and does not contaminate the scrubbing solution. In addition, nitric acid has an economical advantage in the process considering the fact that it is produced in the process. Finally, it can be conducted at ambient temperature. This study furthermore used a mixture of hydrogen peroxide and nitric acid solutions as an absorbent to reduce NOx in hollow fiber membrane modules. The hydrogen peroxide oxidized HNO(2) to nitric acid, while enhances the oxidation through an autocatalytic reaction. The effects of the feed gas flow rate, hydrogen peroxide concentrations and number of fibers on the NOx reduction, absorbed NOx and flux were varied to study. The experimental results showed that the increase in the feed gas flow rate from 100 to 200 mL/min decreased NOx reduction from about 98 to 94% but increased the absorbed NOx and flux from about 0.13 to 0.255 mmol/h and 0.85–1.63 mmol/m(2).h, respectively The increase in proportion of NO(x) in the feed gas effect was dominant than the increase in absorbed NOx. An increase in hydrogen peroxide concentration from 0.5 to 10 wt.% in the absorbent solutions increased NOx reduction, absorbed NOx and flux from about 94 to 98%, 0.257–0.267 mmol/h and 1.09–1.13 mmol/m(2).h, respectively. Additionally, the H(2)O(2) plays an important role in enhancing HNO(2) oxidation to HNO(3). Furthermore, an increase in the number of fibers from 50 to 150 in the membrane module increased NOx reduction and absorbed NOx from 86 to 97% and 0.23–0.27 mmol/h. Flux decreased from 2.98 to 1.13 mmol/m(2).h due to increment in the gas-liquid contact surface area. Elsevier 2019-12-06 /pmc/articles/PMC6911882/ /pubmed/31872135 http://dx.doi.org/10.1016/j.heliyon.2019.e02987 Text en © 2019 The Author(s) http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kartohardjono, Sutrasno Merry, Clarissa Rizky, Mohamad Sofwan Pratita, Catharina Candra Nitrogen oxide reduction through absorbent solutions containing nitric acid and hydrogen peroxide in hollow fiber membrane modules |
title | Nitrogen oxide reduction through absorbent solutions containing nitric acid and hydrogen peroxide in hollow fiber membrane modules |
title_full | Nitrogen oxide reduction through absorbent solutions containing nitric acid and hydrogen peroxide in hollow fiber membrane modules |
title_fullStr | Nitrogen oxide reduction through absorbent solutions containing nitric acid and hydrogen peroxide in hollow fiber membrane modules |
title_full_unstemmed | Nitrogen oxide reduction through absorbent solutions containing nitric acid and hydrogen peroxide in hollow fiber membrane modules |
title_short | Nitrogen oxide reduction through absorbent solutions containing nitric acid and hydrogen peroxide in hollow fiber membrane modules |
title_sort | nitrogen oxide reduction through absorbent solutions containing nitric acid and hydrogen peroxide in hollow fiber membrane modules |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6911882/ https://www.ncbi.nlm.nih.gov/pubmed/31872135 http://dx.doi.org/10.1016/j.heliyon.2019.e02987 |
work_keys_str_mv | AT kartohardjonosutrasno nitrogenoxidereductionthroughabsorbentsolutionscontainingnitricacidandhydrogenperoxideinhollowfibermembranemodules AT merryclarissa nitrogenoxidereductionthroughabsorbentsolutionscontainingnitricacidandhydrogenperoxideinhollowfibermembranemodules AT rizkymohamadsofwan nitrogenoxidereductionthroughabsorbentsolutionscontainingnitricacidandhydrogenperoxideinhollowfibermembranemodules AT pratitacatharinacandra nitrogenoxidereductionthroughabsorbentsolutionscontainingnitricacidandhydrogenperoxideinhollowfibermembranemodules |