Cargando…
Determination of humeral inclination in stemless shoulder arthroplasty using plain radiographs
Plain radiographs of the shoulder are routinely used to assess implant orientation after shoulder arthroplasty. Recently, humeral inclination has come into focus especially in reverse stemless shoulder arthroplasty. But, in X-ray projections not exactly parallel to the base of the humeral component,...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PAGEPress Publications, Pavia, Italy
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6912136/ https://www.ncbi.nlm.nih.gov/pubmed/31897278 http://dx.doi.org/10.4081/or.2019.8194 |
_version_ | 1783479385578274816 |
---|---|
author | Beck, Sascha Martin, Robert J. Patsalis, Theodor Burggraf, Manuel Busch, André Landgraeber, Stefan Alexander, Wegner |
author_facet | Beck, Sascha Martin, Robert J. Patsalis, Theodor Burggraf, Manuel Busch, André Landgraeber, Stefan Alexander, Wegner |
author_sort | Beck, Sascha |
collection | PubMed |
description | Plain radiographs of the shoulder are routinely used to assess implant orientation after shoulder arthroplasty. Recently, humeral inclination has come into focus especially in reverse stemless shoulder arthroplasty. But, in X-ray projections not exactly parallel to the base of the humeral component, the humeral inclination angle cannot be determined precisely. Therefore, we established a mathematical algorithm to calculate the humeral neck shaft angle and counterchecked the formula using plain radiographs of a sawbone model containing a humeral head prosthesis. With increasing angles of retroversion, the base of the humeral component forms an ellipse in plain radiographs. Knowing the width and length of the ellipse as well as the inclination angle in a plain radiograph, the exact inclination angle can be determined using the equation reported below. Thus, independent from the viewing angle or angle of retroversion, the inclination angle of a stemless humeral head implant can be estimated with an accuracy of ±1.5-degree deviation. The algorithm proposed may be the basis for further research on the impact of humeral inclination in stemless shoulder arthroplasty. |
format | Online Article Text |
id | pubmed-6912136 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | PAGEPress Publications, Pavia, Italy |
record_format | MEDLINE/PubMed |
spelling | pubmed-69121362020-01-02 Determination of humeral inclination in stemless shoulder arthroplasty using plain radiographs Beck, Sascha Martin, Robert J. Patsalis, Theodor Burggraf, Manuel Busch, André Landgraeber, Stefan Alexander, Wegner Orthop Rev (Pavia) Article Plain radiographs of the shoulder are routinely used to assess implant orientation after shoulder arthroplasty. Recently, humeral inclination has come into focus especially in reverse stemless shoulder arthroplasty. But, in X-ray projections not exactly parallel to the base of the humeral component, the humeral inclination angle cannot be determined precisely. Therefore, we established a mathematical algorithm to calculate the humeral neck shaft angle and counterchecked the formula using plain radiographs of a sawbone model containing a humeral head prosthesis. With increasing angles of retroversion, the base of the humeral component forms an ellipse in plain radiographs. Knowing the width and length of the ellipse as well as the inclination angle in a plain radiograph, the exact inclination angle can be determined using the equation reported below. Thus, independent from the viewing angle or angle of retroversion, the inclination angle of a stemless humeral head implant can be estimated with an accuracy of ±1.5-degree deviation. The algorithm proposed may be the basis for further research on the impact of humeral inclination in stemless shoulder arthroplasty. PAGEPress Publications, Pavia, Italy 2019-12-02 /pmc/articles/PMC6912136/ /pubmed/31897278 http://dx.doi.org/10.4081/or.2019.8194 Text en ©Copyright: the Author(s), 2019 http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Article Beck, Sascha Martin, Robert J. Patsalis, Theodor Burggraf, Manuel Busch, André Landgraeber, Stefan Alexander, Wegner Determination of humeral inclination in stemless shoulder arthroplasty using plain radiographs |
title | Determination of humeral inclination in stemless shoulder arthroplasty using plain radiographs |
title_full | Determination of humeral inclination in stemless shoulder arthroplasty using plain radiographs |
title_fullStr | Determination of humeral inclination in stemless shoulder arthroplasty using plain radiographs |
title_full_unstemmed | Determination of humeral inclination in stemless shoulder arthroplasty using plain radiographs |
title_short | Determination of humeral inclination in stemless shoulder arthroplasty using plain radiographs |
title_sort | determination of humeral inclination in stemless shoulder arthroplasty using plain radiographs |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6912136/ https://www.ncbi.nlm.nih.gov/pubmed/31897278 http://dx.doi.org/10.4081/or.2019.8194 |
work_keys_str_mv | AT becksascha determinationofhumeralinclinationinstemlessshoulderarthroplastyusingplainradiographs AT martinrobertj determinationofhumeralinclinationinstemlessshoulderarthroplastyusingplainradiographs AT patsalistheodor determinationofhumeralinclinationinstemlessshoulderarthroplastyusingplainradiographs AT burggrafmanuel determinationofhumeralinclinationinstemlessshoulderarthroplastyusingplainradiographs AT buschandre determinationofhumeralinclinationinstemlessshoulderarthroplastyusingplainradiographs AT landgraeberstefan determinationofhumeralinclinationinstemlessshoulderarthroplastyusingplainradiographs AT alexanderwegner determinationofhumeralinclinationinstemlessshoulderarthroplastyusingplainradiographs |