Cargando…
Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance
Life expectancy is on the rise and, concurrently, the demand for total knee arthroplasty (TKA), which lasts a lifetime, is increasing. To meet this demand, improved TKA designs have been introduced. Recent advances in radiography and manufacturing techniques have enabled the production of patient-sp...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6912647/ https://www.ncbi.nlm.nih.gov/pubmed/31752389 http://dx.doi.org/10.3390/jcm8112023 |
_version_ | 1783479505917050880 |
---|---|
author | Koh, Yong-Gon Jung, Kyung-Hwan Hong, Hyoung-Taek Kim, Kang-Min Kang, Kyoung-Tak |
author_facet | Koh, Yong-Gon Jung, Kyung-Hwan Hong, Hyoung-Taek Kim, Kang-Min Kang, Kyoung-Tak |
author_sort | Koh, Yong-Gon |
collection | PubMed |
description | Life expectancy is on the rise and, concurrently, the demand for total knee arthroplasty (TKA), which lasts a lifetime, is increasing. To meet this demand, improved TKA designs have been introduced. Recent advances in radiography and manufacturing techniques have enabled the production of patient-specific TKA. Nevertheless, concerns regarding the wear performance, which limit the lifespan of TKA, remain to be addressed. This study aims at reducing the wear in patient-specific TKA using design optimization and parametric three-dimensional (3D) finite-element (FE) modelling. The femoral component design was implemented in a patient-specific manner, whereas the tibial insert conformity remained to be determined by design variables. The gait cycle loading condition was applied, and the optimized model was validated by the results obtained from the experimental wear tests. The wear predictions were iterated for five million gait cycles using the computational model with force-controlled input. Similar patterns for internal/external rotation and anterior/posterior translation were observed in both initial and optimal models. The wear rates for initial and optimal models were recorded as 23.2 mm(3)/million cycles and 16.7 mm(3)/million cycles, respectively. Moreover, the experimental wear rate in the optimal design was 17.8 mm(3)/million cycles, which validated our optimization procedure. This study suggests that tibial insert conformity is an important factor in influencing the wear performance of patient-specific TKA, and it is capable of providing improved clinical results through enhanced design selections. This finding can boost the future development of patient-specific TKA, and it can be extended to other joint-replacement designs. However, further research is required to explore the potential clinical benefits of the improved wear performance demonstrated in this study. |
format | Online Article Text |
id | pubmed-6912647 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-69126472020-01-02 Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance Koh, Yong-Gon Jung, Kyung-Hwan Hong, Hyoung-Taek Kim, Kang-Min Kang, Kyoung-Tak J Clin Med Article Life expectancy is on the rise and, concurrently, the demand for total knee arthroplasty (TKA), which lasts a lifetime, is increasing. To meet this demand, improved TKA designs have been introduced. Recent advances in radiography and manufacturing techniques have enabled the production of patient-specific TKA. Nevertheless, concerns regarding the wear performance, which limit the lifespan of TKA, remain to be addressed. This study aims at reducing the wear in patient-specific TKA using design optimization and parametric three-dimensional (3D) finite-element (FE) modelling. The femoral component design was implemented in a patient-specific manner, whereas the tibial insert conformity remained to be determined by design variables. The gait cycle loading condition was applied, and the optimized model was validated by the results obtained from the experimental wear tests. The wear predictions were iterated for five million gait cycles using the computational model with force-controlled input. Similar patterns for internal/external rotation and anterior/posterior translation were observed in both initial and optimal models. The wear rates for initial and optimal models were recorded as 23.2 mm(3)/million cycles and 16.7 mm(3)/million cycles, respectively. Moreover, the experimental wear rate in the optimal design was 17.8 mm(3)/million cycles, which validated our optimization procedure. This study suggests that tibial insert conformity is an important factor in influencing the wear performance of patient-specific TKA, and it is capable of providing improved clinical results through enhanced design selections. This finding can boost the future development of patient-specific TKA, and it can be extended to other joint-replacement designs. However, further research is required to explore the potential clinical benefits of the improved wear performance demonstrated in this study. MDPI 2019-11-19 /pmc/articles/PMC6912647/ /pubmed/31752389 http://dx.doi.org/10.3390/jcm8112023 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Koh, Yong-Gon Jung, Kyung-Hwan Hong, Hyoung-Taek Kim, Kang-Min Kang, Kyoung-Tak Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance |
title | Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance |
title_full | Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance |
title_fullStr | Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance |
title_full_unstemmed | Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance |
title_short | Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance |
title_sort | optimal design of patient-specific total knee arthroplasty for improvement in wear performance |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6912647/ https://www.ncbi.nlm.nih.gov/pubmed/31752389 http://dx.doi.org/10.3390/jcm8112023 |
work_keys_str_mv | AT kohyonggon optimaldesignofpatientspecifictotalkneearthroplastyforimprovementinwearperformance AT jungkyunghwan optimaldesignofpatientspecifictotalkneearthroplastyforimprovementinwearperformance AT honghyoungtaek optimaldesignofpatientspecifictotalkneearthroplastyforimprovementinwearperformance AT kimkangmin optimaldesignofpatientspecifictotalkneearthroplastyforimprovementinwearperformance AT kangkyoungtak optimaldesignofpatientspecifictotalkneearthroplastyforimprovementinwearperformance |