Cargando…

Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance

Life expectancy is on the rise and, concurrently, the demand for total knee arthroplasty (TKA), which lasts a lifetime, is increasing. To meet this demand, improved TKA designs have been introduced. Recent advances in radiography and manufacturing techniques have enabled the production of patient-sp...

Descripción completa

Detalles Bibliográficos
Autores principales: Koh, Yong-Gon, Jung, Kyung-Hwan, Hong, Hyoung-Taek, Kim, Kang-Min, Kang, Kyoung-Tak
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6912647/
https://www.ncbi.nlm.nih.gov/pubmed/31752389
http://dx.doi.org/10.3390/jcm8112023
_version_ 1783479505917050880
author Koh, Yong-Gon
Jung, Kyung-Hwan
Hong, Hyoung-Taek
Kim, Kang-Min
Kang, Kyoung-Tak
author_facet Koh, Yong-Gon
Jung, Kyung-Hwan
Hong, Hyoung-Taek
Kim, Kang-Min
Kang, Kyoung-Tak
author_sort Koh, Yong-Gon
collection PubMed
description Life expectancy is on the rise and, concurrently, the demand for total knee arthroplasty (TKA), which lasts a lifetime, is increasing. To meet this demand, improved TKA designs have been introduced. Recent advances in radiography and manufacturing techniques have enabled the production of patient-specific TKA. Nevertheless, concerns regarding the wear performance, which limit the lifespan of TKA, remain to be addressed. This study aims at reducing the wear in patient-specific TKA using design optimization and parametric three-dimensional (3D) finite-element (FE) modelling. The femoral component design was implemented in a patient-specific manner, whereas the tibial insert conformity remained to be determined by design variables. The gait cycle loading condition was applied, and the optimized model was validated by the results obtained from the experimental wear tests. The wear predictions were iterated for five million gait cycles using the computational model with force-controlled input. Similar patterns for internal/external rotation and anterior/posterior translation were observed in both initial and optimal models. The wear rates for initial and optimal models were recorded as 23.2 mm(3)/million cycles and 16.7 mm(3)/million cycles, respectively. Moreover, the experimental wear rate in the optimal design was 17.8 mm(3)/million cycles, which validated our optimization procedure. This study suggests that tibial insert conformity is an important factor in influencing the wear performance of patient-specific TKA, and it is capable of providing improved clinical results through enhanced design selections. This finding can boost the future development of patient-specific TKA, and it can be extended to other joint-replacement designs. However, further research is required to explore the potential clinical benefits of the improved wear performance demonstrated in this study.
format Online
Article
Text
id pubmed-6912647
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69126472020-01-02 Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance Koh, Yong-Gon Jung, Kyung-Hwan Hong, Hyoung-Taek Kim, Kang-Min Kang, Kyoung-Tak J Clin Med Article Life expectancy is on the rise and, concurrently, the demand for total knee arthroplasty (TKA), which lasts a lifetime, is increasing. To meet this demand, improved TKA designs have been introduced. Recent advances in radiography and manufacturing techniques have enabled the production of patient-specific TKA. Nevertheless, concerns regarding the wear performance, which limit the lifespan of TKA, remain to be addressed. This study aims at reducing the wear in patient-specific TKA using design optimization and parametric three-dimensional (3D) finite-element (FE) modelling. The femoral component design was implemented in a patient-specific manner, whereas the tibial insert conformity remained to be determined by design variables. The gait cycle loading condition was applied, and the optimized model was validated by the results obtained from the experimental wear tests. The wear predictions were iterated for five million gait cycles using the computational model with force-controlled input. Similar patterns for internal/external rotation and anterior/posterior translation were observed in both initial and optimal models. The wear rates for initial and optimal models were recorded as 23.2 mm(3)/million cycles and 16.7 mm(3)/million cycles, respectively. Moreover, the experimental wear rate in the optimal design was 17.8 mm(3)/million cycles, which validated our optimization procedure. This study suggests that tibial insert conformity is an important factor in influencing the wear performance of patient-specific TKA, and it is capable of providing improved clinical results through enhanced design selections. This finding can boost the future development of patient-specific TKA, and it can be extended to other joint-replacement designs. However, further research is required to explore the potential clinical benefits of the improved wear performance demonstrated in this study. MDPI 2019-11-19 /pmc/articles/PMC6912647/ /pubmed/31752389 http://dx.doi.org/10.3390/jcm8112023 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Koh, Yong-Gon
Jung, Kyung-Hwan
Hong, Hyoung-Taek
Kim, Kang-Min
Kang, Kyoung-Tak
Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance
title Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance
title_full Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance
title_fullStr Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance
title_full_unstemmed Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance
title_short Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance
title_sort optimal design of patient-specific total knee arthroplasty for improvement in wear performance
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6912647/
https://www.ncbi.nlm.nih.gov/pubmed/31752389
http://dx.doi.org/10.3390/jcm8112023
work_keys_str_mv AT kohyonggon optimaldesignofpatientspecifictotalkneearthroplastyforimprovementinwearperformance
AT jungkyunghwan optimaldesignofpatientspecifictotalkneearthroplastyforimprovementinwearperformance
AT honghyoungtaek optimaldesignofpatientspecifictotalkneearthroplastyforimprovementinwearperformance
AT kimkangmin optimaldesignofpatientspecifictotalkneearthroplastyforimprovementinwearperformance
AT kangkyoungtak optimaldesignofpatientspecifictotalkneearthroplastyforimprovementinwearperformance