Cargando…

Strain Distribution Evaluation of Rat Tibia under Axial Compressive Load by Combining Strain Gauge Measurement and Finite Element Analysis

This study is aimed at providing an effective method for determining strain-load relationship and at quantifying the strain distribution within the whole tibia under axial compressive load on rats. Rat tibial models with axial compressive load were designed. Strains in three directions (0°, 45°, and...

Descripción completa

Detalles Bibliográficos
Autores principales: Gao, Jiazi, Liu, Bei, Zhang, Min, Gong, He, Gao, Bingzhao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6913262/
https://www.ncbi.nlm.nih.gov/pubmed/31871486
http://dx.doi.org/10.1155/2019/1736763
_version_ 1783479629702496256
author Gao, Jiazi
Liu, Bei
Zhang, Min
Gong, He
Gao, Bingzhao
author_facet Gao, Jiazi
Liu, Bei
Zhang, Min
Gong, He
Gao, Bingzhao
author_sort Gao, Jiazi
collection PubMed
description This study is aimed at providing an effective method for determining strain-load relationship and at quantifying the strain distribution within the whole tibia under axial compressive load on rats. Rat tibial models with axial compressive load were designed. Strains in three directions (0°, 45°, and 90°) at the proximal shaft of the tibia were measured by using a strain gauge rosette, which was used to calculate the maximum and minimum principal strains. Moreover, the strain at the midshaft of the tibia was measured by a single-element strain gauge. The slopes of the strain-load curves with different peak loads were calculated to assess the stability of the strain gauge measurement. Mechanical environment in the whole tibia by the axial compressive load was quantified using finite element analysis (FEA) based on microcomputed tomography images. The von Mises elastic strain distributions of the whole tibiae were evaluated. Slopes of the strain-load curves showed no significant differences among different peak loads (ANOVA; P > 0.05), indicating that the strain-load relationship obtained from the strain gauge measurement was reasonable and stable. The FEA results corresponded to the experimental results with an error smaller than 15% (paired Student's t-test, P > 0.05), signifying that the FEA can simulate the experiment reasonably. FEA results showed that the von Mises elastic strain was the lowest in the middle and gradually increased to both sides along the lateral direction, with the maximal von Mises elastic strain being observed on the posterior side under the distal tibiofibular synostosis. The method of strain gauge measurements and FEA used in this study can provide a feasible way to obtain the mechanical environment of the tibiae under axial compressive load on the rats and serve as a reference for further exploring the mechanical response of the bone by axial compressive load.
format Online
Article
Text
id pubmed-6913262
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-69132622019-12-23 Strain Distribution Evaluation of Rat Tibia under Axial Compressive Load by Combining Strain Gauge Measurement and Finite Element Analysis Gao, Jiazi Liu, Bei Zhang, Min Gong, He Gao, Bingzhao Appl Bionics Biomech Research Article This study is aimed at providing an effective method for determining strain-load relationship and at quantifying the strain distribution within the whole tibia under axial compressive load on rats. Rat tibial models with axial compressive load were designed. Strains in three directions (0°, 45°, and 90°) at the proximal shaft of the tibia were measured by using a strain gauge rosette, which was used to calculate the maximum and minimum principal strains. Moreover, the strain at the midshaft of the tibia was measured by a single-element strain gauge. The slopes of the strain-load curves with different peak loads were calculated to assess the stability of the strain gauge measurement. Mechanical environment in the whole tibia by the axial compressive load was quantified using finite element analysis (FEA) based on microcomputed tomography images. The von Mises elastic strain distributions of the whole tibiae were evaluated. Slopes of the strain-load curves showed no significant differences among different peak loads (ANOVA; P > 0.05), indicating that the strain-load relationship obtained from the strain gauge measurement was reasonable and stable. The FEA results corresponded to the experimental results with an error smaller than 15% (paired Student's t-test, P > 0.05), signifying that the FEA can simulate the experiment reasonably. FEA results showed that the von Mises elastic strain was the lowest in the middle and gradually increased to both sides along the lateral direction, with the maximal von Mises elastic strain being observed on the posterior side under the distal tibiofibular synostosis. The method of strain gauge measurements and FEA used in this study can provide a feasible way to obtain the mechanical environment of the tibiae under axial compressive load on the rats and serve as a reference for further exploring the mechanical response of the bone by axial compressive load. Hindawi 2019-12-01 /pmc/articles/PMC6913262/ /pubmed/31871486 http://dx.doi.org/10.1155/2019/1736763 Text en Copyright © 2019 Jiazi Gao et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Gao, Jiazi
Liu, Bei
Zhang, Min
Gong, He
Gao, Bingzhao
Strain Distribution Evaluation of Rat Tibia under Axial Compressive Load by Combining Strain Gauge Measurement and Finite Element Analysis
title Strain Distribution Evaluation of Rat Tibia under Axial Compressive Load by Combining Strain Gauge Measurement and Finite Element Analysis
title_full Strain Distribution Evaluation of Rat Tibia under Axial Compressive Load by Combining Strain Gauge Measurement and Finite Element Analysis
title_fullStr Strain Distribution Evaluation of Rat Tibia under Axial Compressive Load by Combining Strain Gauge Measurement and Finite Element Analysis
title_full_unstemmed Strain Distribution Evaluation of Rat Tibia under Axial Compressive Load by Combining Strain Gauge Measurement and Finite Element Analysis
title_short Strain Distribution Evaluation of Rat Tibia under Axial Compressive Load by Combining Strain Gauge Measurement and Finite Element Analysis
title_sort strain distribution evaluation of rat tibia under axial compressive load by combining strain gauge measurement and finite element analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6913262/
https://www.ncbi.nlm.nih.gov/pubmed/31871486
http://dx.doi.org/10.1155/2019/1736763
work_keys_str_mv AT gaojiazi straindistributionevaluationofrattibiaunderaxialcompressiveloadbycombiningstraingaugemeasurementandfiniteelementanalysis
AT liubei straindistributionevaluationofrattibiaunderaxialcompressiveloadbycombiningstraingaugemeasurementandfiniteelementanalysis
AT zhangmin straindistributionevaluationofrattibiaunderaxialcompressiveloadbycombiningstraingaugemeasurementandfiniteelementanalysis
AT gonghe straindistributionevaluationofrattibiaunderaxialcompressiveloadbycombiningstraingaugemeasurementandfiniteelementanalysis
AT gaobingzhao straindistributionevaluationofrattibiaunderaxialcompressiveloadbycombiningstraingaugemeasurementandfiniteelementanalysis