Cargando…

Pulmonary protection of transcutaneous electrical acupoint stimulation in gynecological laparoscopic surgery: A randomized controlled trial

Laparoscopy is performed worldwide due to its limited side effects and optimal treatment efficacy. However, it also has adverse effects, including atelectasis and ischemia-reperfusion injury, due to CO(2) accumulation during ventilation in a head-down position, which may result in severe disorders a...

Descripción completa

Detalles Bibliográficos
Autores principales: Wei, Wei, Bai, Wenya, Yang, Yanchao, Li, Yang, Teng, Xiufei, Wan, Yuxiao, Zhu, Junchao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6913376/
https://www.ncbi.nlm.nih.gov/pubmed/31885697
http://dx.doi.org/10.3892/etm.2019.8245
_version_ 1783479649880244224
author Wei, Wei
Bai, Wenya
Yang, Yanchao
Li, Yang
Teng, Xiufei
Wan, Yuxiao
Zhu, Junchao
author_facet Wei, Wei
Bai, Wenya
Yang, Yanchao
Li, Yang
Teng, Xiufei
Wan, Yuxiao
Zhu, Junchao
author_sort Wei, Wei
collection PubMed
description Laparoscopy is performed worldwide due to its limited side effects and optimal treatment efficacy. However, it also has adverse effects, including atelectasis and ischemia-reperfusion injury, due to CO(2) accumulation during ventilation in a head-down position, which may result in severe disorders and adversely affecting postoperative recovery, prolonging hospitalization. The present study was performed to assess whether transcutaneous electrical acupoint stimulation (TEAS) protects against lung injury occurring during gynecological laparoscopic surgery. Patients were randomly allocated to two groups: Control group (received no stimulation) and TEAS group (patients treated with TEAS on BL13, LI4 and LU5). The mean arterial pressure, heart rate and oxygen saturation were recorded at the time-points of arriving in the operating room (T(0)), immediately prior to induction of the pneumoperitoneum (T(1)), immediately after the end of pneumoperitoneum (T(2)) and on leaving the operating room (T(3)). Arterial blood gas analysis was performed to record the pH, determine the partial pressure of carbon dioxide and calculate the oxygenation index (OI) at T(0–3). Blood samples were taken from the peripheral vein for determination of the serum concentrations of tumor necrosis factor (TNF)-α and interleukin (IL)-1β at T(0) and T(3). Post-operative pulmonary complications occurring during the first five days after surgery were also recorded. A total of 100 patients were initially enrolled and 80 patients were analysed. The results indicated that the OI in the control group was significantly lower than that in the TEAS group at the T(2) and T(3) time-points. The serum concentrations of TNF-α and IL-1β were significantly increased following surgery, while the extent of these increases was lower in the TEAS group compared with that in the control group. The incidence of post-operative pulmonary complications was significantly lower in the TEAS group. It was therefore indicated that TEAS protect against lung injury as a complication of gynecological laparoscopic surgery. The present study was registered at http://www.clinicaltrials.gov prior to enrollment of the patients (no. NCT02850471).
format Online
Article
Text
id pubmed-6913376
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-69133762019-12-29 Pulmonary protection of transcutaneous electrical acupoint stimulation in gynecological laparoscopic surgery: A randomized controlled trial Wei, Wei Bai, Wenya Yang, Yanchao Li, Yang Teng, Xiufei Wan, Yuxiao Zhu, Junchao Exp Ther Med Articles Laparoscopy is performed worldwide due to its limited side effects and optimal treatment efficacy. However, it also has adverse effects, including atelectasis and ischemia-reperfusion injury, due to CO(2) accumulation during ventilation in a head-down position, which may result in severe disorders and adversely affecting postoperative recovery, prolonging hospitalization. The present study was performed to assess whether transcutaneous electrical acupoint stimulation (TEAS) protects against lung injury occurring during gynecological laparoscopic surgery. Patients were randomly allocated to two groups: Control group (received no stimulation) and TEAS group (patients treated with TEAS on BL13, LI4 and LU5). The mean arterial pressure, heart rate and oxygen saturation were recorded at the time-points of arriving in the operating room (T(0)), immediately prior to induction of the pneumoperitoneum (T(1)), immediately after the end of pneumoperitoneum (T(2)) and on leaving the operating room (T(3)). Arterial blood gas analysis was performed to record the pH, determine the partial pressure of carbon dioxide and calculate the oxygenation index (OI) at T(0–3). Blood samples were taken from the peripheral vein for determination of the serum concentrations of tumor necrosis factor (TNF)-α and interleukin (IL)-1β at T(0) and T(3). Post-operative pulmonary complications occurring during the first five days after surgery were also recorded. A total of 100 patients were initially enrolled and 80 patients were analysed. The results indicated that the OI in the control group was significantly lower than that in the TEAS group at the T(2) and T(3) time-points. The serum concentrations of TNF-α and IL-1β were significantly increased following surgery, while the extent of these increases was lower in the TEAS group compared with that in the control group. The incidence of post-operative pulmonary complications was significantly lower in the TEAS group. It was therefore indicated that TEAS protect against lung injury as a complication of gynecological laparoscopic surgery. The present study was registered at http://www.clinicaltrials.gov prior to enrollment of the patients (no. NCT02850471). D.A. Spandidos 2020-01 2019-11-26 /pmc/articles/PMC6913376/ /pubmed/31885697 http://dx.doi.org/10.3892/etm.2019.8245 Text en Copyright: © Wei et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Wei, Wei
Bai, Wenya
Yang, Yanchao
Li, Yang
Teng, Xiufei
Wan, Yuxiao
Zhu, Junchao
Pulmonary protection of transcutaneous electrical acupoint stimulation in gynecological laparoscopic surgery: A randomized controlled trial
title Pulmonary protection of transcutaneous electrical acupoint stimulation in gynecological laparoscopic surgery: A randomized controlled trial
title_full Pulmonary protection of transcutaneous electrical acupoint stimulation in gynecological laparoscopic surgery: A randomized controlled trial
title_fullStr Pulmonary protection of transcutaneous electrical acupoint stimulation in gynecological laparoscopic surgery: A randomized controlled trial
title_full_unstemmed Pulmonary protection of transcutaneous electrical acupoint stimulation in gynecological laparoscopic surgery: A randomized controlled trial
title_short Pulmonary protection of transcutaneous electrical acupoint stimulation in gynecological laparoscopic surgery: A randomized controlled trial
title_sort pulmonary protection of transcutaneous electrical acupoint stimulation in gynecological laparoscopic surgery: a randomized controlled trial
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6913376/
https://www.ncbi.nlm.nih.gov/pubmed/31885697
http://dx.doi.org/10.3892/etm.2019.8245
work_keys_str_mv AT weiwei pulmonaryprotectionoftranscutaneouselectricalacupointstimulationingynecologicallaparoscopicsurgeryarandomizedcontrolledtrial
AT baiwenya pulmonaryprotectionoftranscutaneouselectricalacupointstimulationingynecologicallaparoscopicsurgeryarandomizedcontrolledtrial
AT yangyanchao pulmonaryprotectionoftranscutaneouselectricalacupointstimulationingynecologicallaparoscopicsurgeryarandomizedcontrolledtrial
AT liyang pulmonaryprotectionoftranscutaneouselectricalacupointstimulationingynecologicallaparoscopicsurgeryarandomizedcontrolledtrial
AT tengxiufei pulmonaryprotectionoftranscutaneouselectricalacupointstimulationingynecologicallaparoscopicsurgeryarandomizedcontrolledtrial
AT wanyuxiao pulmonaryprotectionoftranscutaneouselectricalacupointstimulationingynecologicallaparoscopicsurgeryarandomizedcontrolledtrial
AT zhujunchao pulmonaryprotectionoftranscutaneouselectricalacupointstimulationingynecologicallaparoscopicsurgeryarandomizedcontrolledtrial