Cargando…

An Ambulatory Blood Pressure Monitor Mobile Health System for Early Warning for Stroke Risk: Longitudinal Observational Study

BACKGROUND: Stroke, as a leading cause of death around the globe, has become a heavy burden on our society. Studies show that stroke can be predicted and prevented if a person’s blood pressure (BP) status is appropriately monitored via an ambulatory blood pressure monitor (ABPM) system. However, cur...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Guangyu, Zhou, Silu, Rezaei, Shahbaz, Liu, Xin, Huang, Anpeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6913731/
https://www.ncbi.nlm.nih.gov/pubmed/31670694
http://dx.doi.org/10.2196/14926
_version_ 1783479690345840640
author Wang, Guangyu
Zhou, Silu
Rezaei, Shahbaz
Liu, Xin
Huang, Anpeng
author_facet Wang, Guangyu
Zhou, Silu
Rezaei, Shahbaz
Liu, Xin
Huang, Anpeng
author_sort Wang, Guangyu
collection PubMed
description BACKGROUND: Stroke, as a leading cause of death around the globe, has become a heavy burden on our society. Studies show that stroke can be predicted and prevented if a person’s blood pressure (BP) status is appropriately monitored via an ambulatory blood pressure monitor (ABPM) system. However, currently there exists no efficient and user-friendly ABPM system to provide early warning for stroke risk in real-time. Moreover, most existing ABPM devices measure BP during the deflation of the cuff, which fails to reflect blood pressure accurately. OBJECTIVE: In this study, we sought to develop a new ABPM mobile health (mHealth) system that was capable of monitoring blood pressure during inflation and could detect early stroke-risk signals in real-time. METHODS: We designed an ABPM mHealth system that is based on mobile network infrastructure and mobile apps. The proposed system contains two major parts: a new ABPM device in which an inflation-type BP measurement algorithm is embedded, and an abnormal blood pressure data analysis algorithm for stroke-risk prediction services at our health data service center. For evaluation, the ABPM device was first tested using simulated signals and compared with the gold standard of a mercury sphygmomanometer. Then, the performance of our proposed mHealth system was evaluated in an observational study. RESULTS: The results are presented in two main parts: the device test and the longitudinal observational studies of the presented system. The average measurement error of the new ABPM device with the inflation-type algorithm was less than 0.55 mmHg compared to a reference device using simulated signals. Moreover, the results of correlation coefficients and agreement analyses show that there is a strong linear correlation between our device and the standard mercury sphygmomanometer. In the case of the system observational study, we collected a data set with 88 features, including real-time data, user information, and user records. Our abnormal blood pressure data analysis algorithm achieved the best performance, with an area under the curve of 0.904 for the low risk level, 0.756 for the caution risk level, and 0.912 for the high-risk level. Our system enables a patient to be aware of their risk in real-time, which improves medication adherence with risk self-management. CONCLUSIONS: To our knowledge, this device is the first ABPM device that measures blood pressure during the inflation process and has obtained a government medical license. Device tests and longitudinal observational studies were conducted in Peking University hospitals, and they showed the device’s high accuracy for BP measurements, its efficiency in detecting early signs of stroke, and its efficiency at providing an early warning for stroke risk.
format Online
Article
Text
id pubmed-6913731
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-69137312020-03-04 An Ambulatory Blood Pressure Monitor Mobile Health System for Early Warning for Stroke Risk: Longitudinal Observational Study Wang, Guangyu Zhou, Silu Rezaei, Shahbaz Liu, Xin Huang, Anpeng JMIR Mhealth Uhealth Original Paper BACKGROUND: Stroke, as a leading cause of death around the globe, has become a heavy burden on our society. Studies show that stroke can be predicted and prevented if a person’s blood pressure (BP) status is appropriately monitored via an ambulatory blood pressure monitor (ABPM) system. However, currently there exists no efficient and user-friendly ABPM system to provide early warning for stroke risk in real-time. Moreover, most existing ABPM devices measure BP during the deflation of the cuff, which fails to reflect blood pressure accurately. OBJECTIVE: In this study, we sought to develop a new ABPM mobile health (mHealth) system that was capable of monitoring blood pressure during inflation and could detect early stroke-risk signals in real-time. METHODS: We designed an ABPM mHealth system that is based on mobile network infrastructure and mobile apps. The proposed system contains two major parts: a new ABPM device in which an inflation-type BP measurement algorithm is embedded, and an abnormal blood pressure data analysis algorithm for stroke-risk prediction services at our health data service center. For evaluation, the ABPM device was first tested using simulated signals and compared with the gold standard of a mercury sphygmomanometer. Then, the performance of our proposed mHealth system was evaluated in an observational study. RESULTS: The results are presented in two main parts: the device test and the longitudinal observational studies of the presented system. The average measurement error of the new ABPM device with the inflation-type algorithm was less than 0.55 mmHg compared to a reference device using simulated signals. Moreover, the results of correlation coefficients and agreement analyses show that there is a strong linear correlation between our device and the standard mercury sphygmomanometer. In the case of the system observational study, we collected a data set with 88 features, including real-time data, user information, and user records. Our abnormal blood pressure data analysis algorithm achieved the best performance, with an area under the curve of 0.904 for the low risk level, 0.756 for the caution risk level, and 0.912 for the high-risk level. Our system enables a patient to be aware of their risk in real-time, which improves medication adherence with risk self-management. CONCLUSIONS: To our knowledge, this device is the first ABPM device that measures blood pressure during the inflation process and has obtained a government medical license. Device tests and longitudinal observational studies were conducted in Peking University hospitals, and they showed the device’s high accuracy for BP measurements, its efficiency in detecting early signs of stroke, and its efficiency at providing an early warning for stroke risk. JMIR Publications 2019-10-30 /pmc/articles/PMC6913731/ /pubmed/31670694 http://dx.doi.org/10.2196/14926 Text en ©Guangyu Wang, Silu Zhou, Shahbaz Rezaei, Xin Liu, Anpeng Huang. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 30.10.2019. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mhealth and uhealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Wang, Guangyu
Zhou, Silu
Rezaei, Shahbaz
Liu, Xin
Huang, Anpeng
An Ambulatory Blood Pressure Monitor Mobile Health System for Early Warning for Stroke Risk: Longitudinal Observational Study
title An Ambulatory Blood Pressure Monitor Mobile Health System for Early Warning for Stroke Risk: Longitudinal Observational Study
title_full An Ambulatory Blood Pressure Monitor Mobile Health System for Early Warning for Stroke Risk: Longitudinal Observational Study
title_fullStr An Ambulatory Blood Pressure Monitor Mobile Health System for Early Warning for Stroke Risk: Longitudinal Observational Study
title_full_unstemmed An Ambulatory Blood Pressure Monitor Mobile Health System for Early Warning for Stroke Risk: Longitudinal Observational Study
title_short An Ambulatory Blood Pressure Monitor Mobile Health System for Early Warning for Stroke Risk: Longitudinal Observational Study
title_sort ambulatory blood pressure monitor mobile health system for early warning for stroke risk: longitudinal observational study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6913731/
https://www.ncbi.nlm.nih.gov/pubmed/31670694
http://dx.doi.org/10.2196/14926
work_keys_str_mv AT wangguangyu anambulatorybloodpressuremonitormobilehealthsystemforearlywarningforstrokerisklongitudinalobservationalstudy
AT zhousilu anambulatorybloodpressuremonitormobilehealthsystemforearlywarningforstrokerisklongitudinalobservationalstudy
AT rezaeishahbaz anambulatorybloodpressuremonitormobilehealthsystemforearlywarningforstrokerisklongitudinalobservationalstudy
AT liuxin anambulatorybloodpressuremonitormobilehealthsystemforearlywarningforstrokerisklongitudinalobservationalstudy
AT huanganpeng anambulatorybloodpressuremonitormobilehealthsystemforearlywarningforstrokerisklongitudinalobservationalstudy
AT wangguangyu ambulatorybloodpressuremonitormobilehealthsystemforearlywarningforstrokerisklongitudinalobservationalstudy
AT zhousilu ambulatorybloodpressuremonitormobilehealthsystemforearlywarningforstrokerisklongitudinalobservationalstudy
AT rezaeishahbaz ambulatorybloodpressuremonitormobilehealthsystemforearlywarningforstrokerisklongitudinalobservationalstudy
AT liuxin ambulatorybloodpressuremonitormobilehealthsystemforearlywarningforstrokerisklongitudinalobservationalstudy
AT huanganpeng ambulatorybloodpressuremonitormobilehealthsystemforearlywarningforstrokerisklongitudinalobservationalstudy