Cargando…
Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives
When considering incident investigations and security checks focused on energetic materials, there is an ongoing need for rapid, on-scene chemical identification. Currently applied methods are not capable of meeting all requirements, and hence, portable mass spectrometry is an interesting alternativ...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6914713/ https://www.ncbi.nlm.nih.gov/pubmed/31659718 http://dx.doi.org/10.1007/s13361-019-02335-y |
_version_ | 1783479865440206848 |
---|---|
author | Pintabona, Lauren Astefanei, Alina Corthals, Garry L. van Asten, Arian C. |
author_facet | Pintabona, Lauren Astefanei, Alina Corthals, Garry L. van Asten, Arian C. |
author_sort | Pintabona, Lauren |
collection | PubMed |
description | When considering incident investigations and security checks focused on energetic materials, there is an ongoing need for rapid, on-scene chemical identification. Currently applied methods are not capable of meeting all requirements, and hence, portable mass spectrometry is an interesting alternative although many instrumental challenges still exist. To be able to analyze explosives with mass spectrometry outside the traditional laboratory, suitable ambient ionization methods need to be developed. Ideally such methods are also easily implemented in the field requiring limited to no power sources, gas supplies, flow controllers, and heating devices. For this reason, the potential of SAWN (surface acoustic wave nebulization) for the ambient ionization and subsequent mass spectrometric (MS) analysis of organic explosives was investigated in this study. Excellent sensitivity was observed for nitrate-based organic explosives when operating the MS in negative mode. No dominant adduct peaks were observed for the peroxides TATP and HMTD with SAWN-MS in positive mode. The MS spectra indicate extensive fragmentation of the peroxide explosives even under the mild ionization conditions provided by SAWN. The potential of SAWN-MS was demonstrated with the correct identification of nitrate-based organic explosives in pre- and post-explosion case samples in only a fraction of the time and effort required for the regular laboratory analysis. Results show that SAWN-MS can convincingly identify intact organic energetic compounds and mixtures but that sensitivity is not always sufficient to detect traces of explosives in post-explosion residues. [Image: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s13361-019-02335-y) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6914713 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-69147132020-01-02 Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives Pintabona, Lauren Astefanei, Alina Corthals, Garry L. van Asten, Arian C. J Am Soc Mass Spectrom Research Article When considering incident investigations and security checks focused on energetic materials, there is an ongoing need for rapid, on-scene chemical identification. Currently applied methods are not capable of meeting all requirements, and hence, portable mass spectrometry is an interesting alternative although many instrumental challenges still exist. To be able to analyze explosives with mass spectrometry outside the traditional laboratory, suitable ambient ionization methods need to be developed. Ideally such methods are also easily implemented in the field requiring limited to no power sources, gas supplies, flow controllers, and heating devices. For this reason, the potential of SAWN (surface acoustic wave nebulization) for the ambient ionization and subsequent mass spectrometric (MS) analysis of organic explosives was investigated in this study. Excellent sensitivity was observed for nitrate-based organic explosives when operating the MS in negative mode. No dominant adduct peaks were observed for the peroxides TATP and HMTD with SAWN-MS in positive mode. The MS spectra indicate extensive fragmentation of the peroxide explosives even under the mild ionization conditions provided by SAWN. The potential of SAWN-MS was demonstrated with the correct identification of nitrate-based organic explosives in pre- and post-explosion case samples in only a fraction of the time and effort required for the regular laboratory analysis. Results show that SAWN-MS can convincingly identify intact organic energetic compounds and mixtures but that sensitivity is not always sufficient to detect traces of explosives in post-explosion residues. [Image: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s13361-019-02335-y) contains supplementary material, which is available to authorized users. Springer US 2019-10-28 2019 /pmc/articles/PMC6914713/ /pubmed/31659718 http://dx.doi.org/10.1007/s13361-019-02335-y Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Article Pintabona, Lauren Astefanei, Alina Corthals, Garry L. van Asten, Arian C. Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives |
title | Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives |
title_full | Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives |
title_fullStr | Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives |
title_full_unstemmed | Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives |
title_short | Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives |
title_sort | utilizing surface acoustic wave nebulization (sawn) for the rapid and sensitive ambient ionization mass spectrometric analysis of organic explosives |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6914713/ https://www.ncbi.nlm.nih.gov/pubmed/31659718 http://dx.doi.org/10.1007/s13361-019-02335-y |
work_keys_str_mv | AT pintabonalauren utilizingsurfaceacousticwavenebulizationsawnfortherapidandsensitiveambientionizationmassspectrometricanalysisoforganicexplosives AT astefaneialina utilizingsurfaceacousticwavenebulizationsawnfortherapidandsensitiveambientionizationmassspectrometricanalysisoforganicexplosives AT corthalsgarryl utilizingsurfaceacousticwavenebulizationsawnfortherapidandsensitiveambientionizationmassspectrometricanalysisoforganicexplosives AT vanastenarianc utilizingsurfaceacousticwavenebulizationsawnfortherapidandsensitiveambientionizationmassspectrometricanalysisoforganicexplosives |