Cargando…

Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives

When considering incident investigations and security checks focused on energetic materials, there is an ongoing need for rapid, on-scene chemical identification. Currently applied methods are not capable of meeting all requirements, and hence, portable mass spectrometry is an interesting alternativ...

Descripción completa

Detalles Bibliográficos
Autores principales: Pintabona, Lauren, Astefanei, Alina, Corthals, Garry L., van Asten, Arian C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6914713/
https://www.ncbi.nlm.nih.gov/pubmed/31659718
http://dx.doi.org/10.1007/s13361-019-02335-y
_version_ 1783479865440206848
author Pintabona, Lauren
Astefanei, Alina
Corthals, Garry L.
van Asten, Arian C.
author_facet Pintabona, Lauren
Astefanei, Alina
Corthals, Garry L.
van Asten, Arian C.
author_sort Pintabona, Lauren
collection PubMed
description When considering incident investigations and security checks focused on energetic materials, there is an ongoing need for rapid, on-scene chemical identification. Currently applied methods are not capable of meeting all requirements, and hence, portable mass spectrometry is an interesting alternative although many instrumental challenges still exist. To be able to analyze explosives with mass spectrometry outside the traditional laboratory, suitable ambient ionization methods need to be developed. Ideally such methods are also easily implemented in the field requiring limited to no power sources, gas supplies, flow controllers, and heating devices. For this reason, the potential of SAWN (surface acoustic wave nebulization) for the ambient ionization and subsequent mass spectrometric (MS) analysis of organic explosives was investigated in this study. Excellent sensitivity was observed for nitrate-based organic explosives when operating the MS in negative mode. No dominant adduct peaks were observed for the peroxides TATP and HMTD with SAWN-MS in positive mode. The MS spectra indicate extensive fragmentation of the peroxide explosives even under the mild ionization conditions provided by SAWN. The potential of SAWN-MS was demonstrated with the correct identification of nitrate-based organic explosives in pre- and post-explosion case samples in only a fraction of the time and effort required for the regular laboratory analysis. Results show that SAWN-MS can convincingly identify intact organic energetic compounds and mixtures but that sensitivity is not always sufficient to detect traces of explosives in post-explosion residues. [Image: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s13361-019-02335-y) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6914713
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-69147132020-01-02 Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives Pintabona, Lauren Astefanei, Alina Corthals, Garry L. van Asten, Arian C. J Am Soc Mass Spectrom Research Article When considering incident investigations and security checks focused on energetic materials, there is an ongoing need for rapid, on-scene chemical identification. Currently applied methods are not capable of meeting all requirements, and hence, portable mass spectrometry is an interesting alternative although many instrumental challenges still exist. To be able to analyze explosives with mass spectrometry outside the traditional laboratory, suitable ambient ionization methods need to be developed. Ideally such methods are also easily implemented in the field requiring limited to no power sources, gas supplies, flow controllers, and heating devices. For this reason, the potential of SAWN (surface acoustic wave nebulization) for the ambient ionization and subsequent mass spectrometric (MS) analysis of organic explosives was investigated in this study. Excellent sensitivity was observed for nitrate-based organic explosives when operating the MS in negative mode. No dominant adduct peaks were observed for the peroxides TATP and HMTD with SAWN-MS in positive mode. The MS spectra indicate extensive fragmentation of the peroxide explosives even under the mild ionization conditions provided by SAWN. The potential of SAWN-MS was demonstrated with the correct identification of nitrate-based organic explosives in pre- and post-explosion case samples in only a fraction of the time and effort required for the regular laboratory analysis. Results show that SAWN-MS can convincingly identify intact organic energetic compounds and mixtures but that sensitivity is not always sufficient to detect traces of explosives in post-explosion residues. [Image: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s13361-019-02335-y) contains supplementary material, which is available to authorized users. Springer US 2019-10-28 2019 /pmc/articles/PMC6914713/ /pubmed/31659718 http://dx.doi.org/10.1007/s13361-019-02335-y Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research Article
Pintabona, Lauren
Astefanei, Alina
Corthals, Garry L.
van Asten, Arian C.
Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives
title Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives
title_full Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives
title_fullStr Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives
title_full_unstemmed Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives
title_short Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives
title_sort utilizing surface acoustic wave nebulization (sawn) for the rapid and sensitive ambient ionization mass spectrometric analysis of organic explosives
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6914713/
https://www.ncbi.nlm.nih.gov/pubmed/31659718
http://dx.doi.org/10.1007/s13361-019-02335-y
work_keys_str_mv AT pintabonalauren utilizingsurfaceacousticwavenebulizationsawnfortherapidandsensitiveambientionizationmassspectrometricanalysisoforganicexplosives
AT astefaneialina utilizingsurfaceacousticwavenebulizationsawnfortherapidandsensitiveambientionizationmassspectrometricanalysisoforganicexplosives
AT corthalsgarryl utilizingsurfaceacousticwavenebulizationsawnfortherapidandsensitiveambientionizationmassspectrometricanalysisoforganicexplosives
AT vanastenarianc utilizingsurfaceacousticwavenebulizationsawnfortherapidandsensitiveambientionizationmassspectrometricanalysisoforganicexplosives