Cargando…
Design Analysis and Experimental Study of Robotic Chair for Proton Heavy Ion Radiotherapy
Proton heavy ion radiotherapy is widely used and currently represents the most advanced radiotherapy technology. However, at present, proton heavy ion radiotherapy chairs in fixed beam radiotherapy rooms do not have a head and neck positioning function. This paper presents a novel design for a proto...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6914987/ https://www.ncbi.nlm.nih.gov/pubmed/31885688 http://dx.doi.org/10.1155/2019/6410941 |
_version_ | 1783479928777342976 |
---|---|
author | Zhang, Yongde Yang, Zhikang Jiang, Jingang Dai, Xuesong Qin, Peiwang Guo, Shijie Zuo, Sihao |
author_facet | Zhang, Yongde Yang, Zhikang Jiang, Jingang Dai, Xuesong Qin, Peiwang Guo, Shijie Zuo, Sihao |
author_sort | Zhang, Yongde |
collection | PubMed |
description | Proton heavy ion radiotherapy is widely used and currently represents the most advanced radiotherapy technology. However, at present, proton heavy ion radiotherapy chairs in fixed beam radiotherapy rooms do not have a head and neck positioning function. This paper presents a novel design for a proton heavy ion radiotherapy chair with a head and neck positioning device. The design of the posture adjustment mechanism and the head and neck positioning device of the treatment chair is based on U-TRIZ theory and ergonomics, respectively. A positive kinematic analysis of the posture adjusting mechanism was carried out, as well as a workspace analysis of the head and neck positioning device. Finally, positioning error experiment and ergonomic evaluation were performed on a prototype of the head and neck positioning device. The proposed design of the treatment chair satisfies the requirements for posture adjustment and achieves the head and neck positioning function. The experimental results also provide a basis for further optimization of the design. |
format | Online Article Text |
id | pubmed-6914987 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-69149872019-12-29 Design Analysis and Experimental Study of Robotic Chair for Proton Heavy Ion Radiotherapy Zhang, Yongde Yang, Zhikang Jiang, Jingang Dai, Xuesong Qin, Peiwang Guo, Shijie Zuo, Sihao Appl Bionics Biomech Research Article Proton heavy ion radiotherapy is widely used and currently represents the most advanced radiotherapy technology. However, at present, proton heavy ion radiotherapy chairs in fixed beam radiotherapy rooms do not have a head and neck positioning function. This paper presents a novel design for a proton heavy ion radiotherapy chair with a head and neck positioning device. The design of the posture adjustment mechanism and the head and neck positioning device of the treatment chair is based on U-TRIZ theory and ergonomics, respectively. A positive kinematic analysis of the posture adjusting mechanism was carried out, as well as a workspace analysis of the head and neck positioning device. Finally, positioning error experiment and ergonomic evaluation were performed on a prototype of the head and neck positioning device. The proposed design of the treatment chair satisfies the requirements for posture adjustment and achieves the head and neck positioning function. The experimental results also provide a basis for further optimization of the design. Hindawi 2019-12-01 /pmc/articles/PMC6914987/ /pubmed/31885688 http://dx.doi.org/10.1155/2019/6410941 Text en Copyright © 2019 Yongde Zhang et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhang, Yongde Yang, Zhikang Jiang, Jingang Dai, Xuesong Qin, Peiwang Guo, Shijie Zuo, Sihao Design Analysis and Experimental Study of Robotic Chair for Proton Heavy Ion Radiotherapy |
title | Design Analysis and Experimental Study of Robotic Chair for Proton Heavy Ion Radiotherapy |
title_full | Design Analysis and Experimental Study of Robotic Chair for Proton Heavy Ion Radiotherapy |
title_fullStr | Design Analysis and Experimental Study of Robotic Chair for Proton Heavy Ion Radiotherapy |
title_full_unstemmed | Design Analysis and Experimental Study of Robotic Chair for Proton Heavy Ion Radiotherapy |
title_short | Design Analysis and Experimental Study of Robotic Chair for Proton Heavy Ion Radiotherapy |
title_sort | design analysis and experimental study of robotic chair for proton heavy ion radiotherapy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6914987/ https://www.ncbi.nlm.nih.gov/pubmed/31885688 http://dx.doi.org/10.1155/2019/6410941 |
work_keys_str_mv | AT zhangyongde designanalysisandexperimentalstudyofroboticchairforprotonheavyionradiotherapy AT yangzhikang designanalysisandexperimentalstudyofroboticchairforprotonheavyionradiotherapy AT jiangjingang designanalysisandexperimentalstudyofroboticchairforprotonheavyionradiotherapy AT daixuesong designanalysisandexperimentalstudyofroboticchairforprotonheavyionradiotherapy AT qinpeiwang designanalysisandexperimentalstudyofroboticchairforprotonheavyionradiotherapy AT guoshijie designanalysisandexperimentalstudyofroboticchairforprotonheavyionradiotherapy AT zuosihao designanalysisandexperimentalstudyofroboticchairforprotonheavyionradiotherapy |