Development of a blood sample detector for multi-tracer positron emission tomography using gamma spectroscopy
BACKGROUND: Multi-tracer positron emission tomography (PET) imaging can be accomplished by applying multi-tracer compartment modeling. Recently, a method has been proposed in which the arterial input functions (AIFs) of the multi-tracer PET scan are explicitly derived. For that purpose, a gamma spec...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6915254/ https://www.ncbi.nlm.nih.gov/pubmed/31845002 http://dx.doi.org/10.1186/s40658-019-0263-x |
_version_ | 1783479973284151296 |
---|---|
author | Velasco, Carlos Mota-Cobián, Adriana Mateo, Jesús España, Samuel |
author_facet | Velasco, Carlos Mota-Cobián, Adriana Mateo, Jesús España, Samuel |
author_sort | Velasco, Carlos |
collection | PubMed |
description | BACKGROUND: Multi-tracer positron emission tomography (PET) imaging can be accomplished by applying multi-tracer compartment modeling. Recently, a method has been proposed in which the arterial input functions (AIFs) of the multi-tracer PET scan are explicitly derived. For that purpose, a gamma spectroscopic analysis is performed on blood samples manually withdrawn from the patient when at least one of the co-injected tracers is based on a non-pure positron emitter. Alternatively, these blood samples required for the spectroscopic analysis may be obtained and analyzed on site by an automated detection device, thus minimizing analysis time and radiation exposure of the operating personnel. In this work, a new automated blood sample detector based on silicon photomultipliers (SiPMs) for single- and multi-tracer PET imaging is presented, characterized, and tested in vitro and in vivo. RESULTS: The detector presented in this work stores and analyzes on-the-fly single and coincidence detected events. A sensitivity of 22.6 cps/(kBq/mL) and 1.7 cps/(kBq/mL) was obtained for single and coincidence events respectively. An energy resolution of 35% full-width-half-maximum (FWHM) at 511 keV and a minimum detectable activity of 0.30 ± 0.08 kBq/mL in single mode were obtained. The in vivo AIFs obtained with the detector show an excellent Pearson’s correlation (r = 0.996, p < 0.0001) with the ones obtained from well counter analysis of discrete blood samples. Moreover, in vitro experiments demonstrate the capability of the detector to apply the gamma spectroscopic analysis on a mixture of (68)Ga and (18)F and separate the individual signal emitted from each one. CONCLUSIONS: Characterization and in vivo evaluation under realistic experimental conditions showed that the detector proposed in this work offers excellent sensibility and stability. The device also showed to successfully separate individual signals emitted from a mixture of radioisotopes. Therefore, the blood sample detector presented in this study allows fully automatic AIFs measurements during single- and multi-tracer PET studies. |
format | Online Article Text |
id | pubmed-6915254 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-69152542019-12-30 Development of a blood sample detector for multi-tracer positron emission tomography using gamma spectroscopy Velasco, Carlos Mota-Cobián, Adriana Mateo, Jesús España, Samuel EJNMMI Phys Original Research BACKGROUND: Multi-tracer positron emission tomography (PET) imaging can be accomplished by applying multi-tracer compartment modeling. Recently, a method has been proposed in which the arterial input functions (AIFs) of the multi-tracer PET scan are explicitly derived. For that purpose, a gamma spectroscopic analysis is performed on blood samples manually withdrawn from the patient when at least one of the co-injected tracers is based on a non-pure positron emitter. Alternatively, these blood samples required for the spectroscopic analysis may be obtained and analyzed on site by an automated detection device, thus minimizing analysis time and radiation exposure of the operating personnel. In this work, a new automated blood sample detector based on silicon photomultipliers (SiPMs) for single- and multi-tracer PET imaging is presented, characterized, and tested in vitro and in vivo. RESULTS: The detector presented in this work stores and analyzes on-the-fly single and coincidence detected events. A sensitivity of 22.6 cps/(kBq/mL) and 1.7 cps/(kBq/mL) was obtained for single and coincidence events respectively. An energy resolution of 35% full-width-half-maximum (FWHM) at 511 keV and a minimum detectable activity of 0.30 ± 0.08 kBq/mL in single mode were obtained. The in vivo AIFs obtained with the detector show an excellent Pearson’s correlation (r = 0.996, p < 0.0001) with the ones obtained from well counter analysis of discrete blood samples. Moreover, in vitro experiments demonstrate the capability of the detector to apply the gamma spectroscopic analysis on a mixture of (68)Ga and (18)F and separate the individual signal emitted from each one. CONCLUSIONS: Characterization and in vivo evaluation under realistic experimental conditions showed that the detector proposed in this work offers excellent sensibility and stability. The device also showed to successfully separate individual signals emitted from a mixture of radioisotopes. Therefore, the blood sample detector presented in this study allows fully automatic AIFs measurements during single- and multi-tracer PET studies. Springer International Publishing 2019-12-16 /pmc/articles/PMC6915254/ /pubmed/31845002 http://dx.doi.org/10.1186/s40658-019-0263-x Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Research Velasco, Carlos Mota-Cobián, Adriana Mateo, Jesús España, Samuel Development of a blood sample detector for multi-tracer positron emission tomography using gamma spectroscopy |
title | Development of a blood sample detector for multi-tracer positron emission tomography using gamma spectroscopy |
title_full | Development of a blood sample detector for multi-tracer positron emission tomography using gamma spectroscopy |
title_fullStr | Development of a blood sample detector for multi-tracer positron emission tomography using gamma spectroscopy |
title_full_unstemmed | Development of a blood sample detector for multi-tracer positron emission tomography using gamma spectroscopy |
title_short | Development of a blood sample detector for multi-tracer positron emission tomography using gamma spectroscopy |
title_sort | development of a blood sample detector for multi-tracer positron emission tomography using gamma spectroscopy |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6915254/ https://www.ncbi.nlm.nih.gov/pubmed/31845002 http://dx.doi.org/10.1186/s40658-019-0263-x |
work_keys_str_mv | AT velascocarlos developmentofabloodsampledetectorformultitracerpositronemissiontomographyusinggammaspectroscopy AT motacobianadriana developmentofabloodsampledetectorformultitracerpositronemissiontomographyusinggammaspectroscopy AT mateojesus developmentofabloodsampledetectorformultitracerpositronemissiontomographyusinggammaspectroscopy AT espanasamuel developmentofabloodsampledetectorformultitracerpositronemissiontomographyusinggammaspectroscopy |