Cargando…

The Analysis of the Influence of Threshold on the Dynamic Contact Process of a Fabricated Vertically Driven MEMS Inertial Switch

In this work, to evaluate the influence of the threshold on the dynamic contact process, five models (number 1, 2, 3, 4, 5) with different thresholds were proposed and fabricated with surface micromachining technology. The contact time and response time were used to characterize the dynamic contact...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Wenguo, Wang, Rui, Wang, Huiying, Kong, Dejian, Sun, Shulei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6915417/
https://www.ncbi.nlm.nih.gov/pubmed/31752181
http://dx.doi.org/10.3390/mi10110791
_version_ 1783480011157667840
author Chen, Wenguo
Wang, Rui
Wang, Huiying
Kong, Dejian
Sun, Shulei
author_facet Chen, Wenguo
Wang, Rui
Wang, Huiying
Kong, Dejian
Sun, Shulei
author_sort Chen, Wenguo
collection PubMed
description In this work, to evaluate the influence of the threshold on the dynamic contact process, five models (number 1, 2, 3, 4, 5) with different thresholds were proposed and fabricated with surface micromachining technology. The contact time and response time were used to characterize the dynamic contact performance. The dynamic contact processes of the inertial switches with gradually increasing thresholds were researched using analytical, simulation, and experimental methods. The basic working principle analysis of the inertial switch shows that the contact time of the inertial switch with a low-g value can be extended by using a simply supported beam as the fixed electrode, but the high-G inertial needs more elasticity for fixed electrode. The simulation results indicate that the response time and contact time decrease with the increment in the designed threshold. Prototypes were tested using a dropping hammer system, and the test result indicates that the contact time of the inertial switch with a fixed electrode of the simply supported beam is about 15 and 5 μs when the threshold is about 280 and 580 g, respectively. Meanwhile, the contact time can be extended to 100 μs for the inertial switch using a spring as the fixed electrode when the threshold is about 280 and 580 g. These test results not only prove that the spring fixed electrode can effectively extend the contact time, but also prove that the style of the fixed electrode is the deciding factor affecting the contact time of the high-G inertial switch.
format Online
Article
Text
id pubmed-6915417
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69154172019-12-24 The Analysis of the Influence of Threshold on the Dynamic Contact Process of a Fabricated Vertically Driven MEMS Inertial Switch Chen, Wenguo Wang, Rui Wang, Huiying Kong, Dejian Sun, Shulei Micromachines (Basel) Article In this work, to evaluate the influence of the threshold on the dynamic contact process, five models (number 1, 2, 3, 4, 5) with different thresholds were proposed and fabricated with surface micromachining technology. The contact time and response time were used to characterize the dynamic contact performance. The dynamic contact processes of the inertial switches with gradually increasing thresholds were researched using analytical, simulation, and experimental methods. The basic working principle analysis of the inertial switch shows that the contact time of the inertial switch with a low-g value can be extended by using a simply supported beam as the fixed electrode, but the high-G inertial needs more elasticity for fixed electrode. The simulation results indicate that the response time and contact time decrease with the increment in the designed threshold. Prototypes were tested using a dropping hammer system, and the test result indicates that the contact time of the inertial switch with a fixed electrode of the simply supported beam is about 15 and 5 μs when the threshold is about 280 and 580 g, respectively. Meanwhile, the contact time can be extended to 100 μs for the inertial switch using a spring as the fixed electrode when the threshold is about 280 and 580 g. These test results not only prove that the spring fixed electrode can effectively extend the contact time, but also prove that the style of the fixed electrode is the deciding factor affecting the contact time of the high-G inertial switch. MDPI 2019-11-18 /pmc/articles/PMC6915417/ /pubmed/31752181 http://dx.doi.org/10.3390/mi10110791 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chen, Wenguo
Wang, Rui
Wang, Huiying
Kong, Dejian
Sun, Shulei
The Analysis of the Influence of Threshold on the Dynamic Contact Process of a Fabricated Vertically Driven MEMS Inertial Switch
title The Analysis of the Influence of Threshold on the Dynamic Contact Process of a Fabricated Vertically Driven MEMS Inertial Switch
title_full The Analysis of the Influence of Threshold on the Dynamic Contact Process of a Fabricated Vertically Driven MEMS Inertial Switch
title_fullStr The Analysis of the Influence of Threshold on the Dynamic Contact Process of a Fabricated Vertically Driven MEMS Inertial Switch
title_full_unstemmed The Analysis of the Influence of Threshold on the Dynamic Contact Process of a Fabricated Vertically Driven MEMS Inertial Switch
title_short The Analysis of the Influence of Threshold on the Dynamic Contact Process of a Fabricated Vertically Driven MEMS Inertial Switch
title_sort analysis of the influence of threshold on the dynamic contact process of a fabricated vertically driven mems inertial switch
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6915417/
https://www.ncbi.nlm.nih.gov/pubmed/31752181
http://dx.doi.org/10.3390/mi10110791
work_keys_str_mv AT chenwenguo theanalysisoftheinfluenceofthresholdonthedynamiccontactprocessofafabricatedverticallydrivenmemsinertialswitch
AT wangrui theanalysisoftheinfluenceofthresholdonthedynamiccontactprocessofafabricatedverticallydrivenmemsinertialswitch
AT wanghuiying theanalysisoftheinfluenceofthresholdonthedynamiccontactprocessofafabricatedverticallydrivenmemsinertialswitch
AT kongdejian theanalysisoftheinfluenceofthresholdonthedynamiccontactprocessofafabricatedverticallydrivenmemsinertialswitch
AT sunshulei theanalysisoftheinfluenceofthresholdonthedynamiccontactprocessofafabricatedverticallydrivenmemsinertialswitch
AT chenwenguo analysisoftheinfluenceofthresholdonthedynamiccontactprocessofafabricatedverticallydrivenmemsinertialswitch
AT wangrui analysisoftheinfluenceofthresholdonthedynamiccontactprocessofafabricatedverticallydrivenmemsinertialswitch
AT wanghuiying analysisoftheinfluenceofthresholdonthedynamiccontactprocessofafabricatedverticallydrivenmemsinertialswitch
AT kongdejian analysisoftheinfluenceofthresholdonthedynamiccontactprocessofafabricatedverticallydrivenmemsinertialswitch
AT sunshulei analysisoftheinfluenceofthresholdonthedynamiccontactprocessofafabricatedverticallydrivenmemsinertialswitch