Validation of Single Centre Pre-Mobile Atrial Fibrillation Apps for Continuous Monitoring of Atrial Fibrillation in a Real-World Setting: Pilot Cohort Study

BACKGROUND: Atrial fibrillation is the most common recurrent arrhythmia in clinical practice, with most clinical events occurring outside the hospital. Low detection and nonadherence to guidelines are the primary obstacles to atrial fibrillation management. Photoplethysmography is a novel technology...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Hui, Zhang, Jie, Li, Hong-Bao, Chen, Yi-Xin, Yang, Bin, Guo, Yu-Tao, Chen, Yun-Dai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6918204/
https://www.ncbi.nlm.nih.gov/pubmed/31793887
http://dx.doi.org/10.2196/14909
_version_ 1783480536614830080
author Zhang, Hui
Zhang, Jie
Li, Hong-Bao
Chen, Yi-Xin
Yang, Bin
Guo, Yu-Tao
Chen, Yun-Dai
author_facet Zhang, Hui
Zhang, Jie
Li, Hong-Bao
Chen, Yi-Xin
Yang, Bin
Guo, Yu-Tao
Chen, Yun-Dai
author_sort Zhang, Hui
collection PubMed
description BACKGROUND: Atrial fibrillation is the most common recurrent arrhythmia in clinical practice, with most clinical events occurring outside the hospital. Low detection and nonadherence to guidelines are the primary obstacles to atrial fibrillation management. Photoplethysmography is a novel technology developed for atrial fibrillation screening. However, there has been limited validation of photoplethysmography-based smart devices for the detection of atrial fibrillation and its underlying clinical factors impacting detection. OBJECTIVE: This study aimed to explore the feasibility of photoplethysmography-based smart devices for the detection of atrial fibrillation in real-world settings. METHODS: Subjects aged ≥18 years (n=361) were recruited from September 14 to October 16, 2018, for screening of atrial fibrillation with active measurement, initiated by the users, using photoplethysmography-based smart wearable devices (ie, a smart band or smart watches). Of these, 200 subjects were also automatically and periodically monitored for 14 days with a smart band. The baseline diagnosis of “suspected” atrial fibrillation was confirmed by electrocardiogram and physical examination. The sensitivity and accuracy of photoplethysmography-based smart devices for monitoring atrial fibrillation were evaluated. RESULTS: A total of 2353 active measurement signals and 23,864 periodic measurement signals were recorded. Eleven subjects were confirmed to have persistent atrial fibrillation, and 20 were confirmed to have paroxysmal atrial fibrillation. Smart devices demonstrated >91% predictive ability for atrial fibrillation. The sensitivity and specificity of devices in detecting atrial fibrillation among active recording of the 361 subjects were 100% and about 99%, respectively. For subjects with persistent atrial fibrillation, 127 (97.0%) active measurements and 2240 (99.2%) periodic measurements were identified as atrial fibrillation by the algorithm. For subjects with paroxysmal atrial fibrillation, 36 (17%) active measurements and 717 (19.8%) periodic measurements were identified as atrial fibrillation by the algorithm. All persistent atrial fibrillation cases could be detected as “atrial fibrillation episodes” by the photoplethysmography algorithm on the first monitoring day, while 14 (70%) patients with paroxysmal atrial fibrillation demonstrated “atrial fibrillation episodes” within the first 6 days. The average time to detect paroxysmal atrial fibrillation was 2 days (interquartile range: 1.25-5.75) by active measurement and 1 day (interquartile range: 1.00-2.00) by periodic measurement (P=.10). The first detection time of atrial fibrillation burden of <50% per 24 hours was 4 days by active measurement and 2 days by periodic measurementThe first detection time of atrial fibrillation burden of >50% per 24 hours was 1 day for both active and periodic measurements (active measurement: P=.02, periodic measurement: P=.03). CONCLUSIONS: Photoplethysmography-based smart devices demonstrated good atrial fibrillation predictive ability in both active and periodic measurements. However, atrial fibrillation type could impact detection, resulting in increased monitoring time. TRIAL REGISTRATION: Chinese Clinical Trial Registry of the International Clinical Trials Registry Platform of the World Health Organization ChiCTR-OOC-17014138; http://www.chictr.org.cn/showprojen.aspx?proj=24191.
format Online
Article
Text
id pubmed-6918204
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-69182042020-01-06 Validation of Single Centre Pre-Mobile Atrial Fibrillation Apps for Continuous Monitoring of Atrial Fibrillation in a Real-World Setting: Pilot Cohort Study Zhang, Hui Zhang, Jie Li, Hong-Bao Chen, Yi-Xin Yang, Bin Guo, Yu-Tao Chen, Yun-Dai J Med Internet Res Original Paper BACKGROUND: Atrial fibrillation is the most common recurrent arrhythmia in clinical practice, with most clinical events occurring outside the hospital. Low detection and nonadherence to guidelines are the primary obstacles to atrial fibrillation management. Photoplethysmography is a novel technology developed for atrial fibrillation screening. However, there has been limited validation of photoplethysmography-based smart devices for the detection of atrial fibrillation and its underlying clinical factors impacting detection. OBJECTIVE: This study aimed to explore the feasibility of photoplethysmography-based smart devices for the detection of atrial fibrillation in real-world settings. METHODS: Subjects aged ≥18 years (n=361) were recruited from September 14 to October 16, 2018, for screening of atrial fibrillation with active measurement, initiated by the users, using photoplethysmography-based smart wearable devices (ie, a smart band or smart watches). Of these, 200 subjects were also automatically and periodically monitored for 14 days with a smart band. The baseline diagnosis of “suspected” atrial fibrillation was confirmed by electrocardiogram and physical examination. The sensitivity and accuracy of photoplethysmography-based smart devices for monitoring atrial fibrillation were evaluated. RESULTS: A total of 2353 active measurement signals and 23,864 periodic measurement signals were recorded. Eleven subjects were confirmed to have persistent atrial fibrillation, and 20 were confirmed to have paroxysmal atrial fibrillation. Smart devices demonstrated >91% predictive ability for atrial fibrillation. The sensitivity and specificity of devices in detecting atrial fibrillation among active recording of the 361 subjects were 100% and about 99%, respectively. For subjects with persistent atrial fibrillation, 127 (97.0%) active measurements and 2240 (99.2%) periodic measurements were identified as atrial fibrillation by the algorithm. For subjects with paroxysmal atrial fibrillation, 36 (17%) active measurements and 717 (19.8%) periodic measurements were identified as atrial fibrillation by the algorithm. All persistent atrial fibrillation cases could be detected as “atrial fibrillation episodes” by the photoplethysmography algorithm on the first monitoring day, while 14 (70%) patients with paroxysmal atrial fibrillation demonstrated “atrial fibrillation episodes” within the first 6 days. The average time to detect paroxysmal atrial fibrillation was 2 days (interquartile range: 1.25-5.75) by active measurement and 1 day (interquartile range: 1.00-2.00) by periodic measurement (P=.10). The first detection time of atrial fibrillation burden of <50% per 24 hours was 4 days by active measurement and 2 days by periodic measurementThe first detection time of atrial fibrillation burden of >50% per 24 hours was 1 day for both active and periodic measurements (active measurement: P=.02, periodic measurement: P=.03). CONCLUSIONS: Photoplethysmography-based smart devices demonstrated good atrial fibrillation predictive ability in both active and periodic measurements. However, atrial fibrillation type could impact detection, resulting in increased monitoring time. TRIAL REGISTRATION: Chinese Clinical Trial Registry of the International Clinical Trials Registry Platform of the World Health Organization ChiCTR-OOC-17014138; http://www.chictr.org.cn/showprojen.aspx?proj=24191. JMIR Publications 2019-12-03 /pmc/articles/PMC6918204/ /pubmed/31793887 http://dx.doi.org/10.2196/14909 Text en ©Hui Zhang, Jie Zhang, Hong-Bao Li, Yi-Xin Chen, Bin Yang, Yu-Tao Guo, Yun-Dai Chen. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 03.12.2019. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on http://www.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Zhang, Hui
Zhang, Jie
Li, Hong-Bao
Chen, Yi-Xin
Yang, Bin
Guo, Yu-Tao
Chen, Yun-Dai
Validation of Single Centre Pre-Mobile Atrial Fibrillation Apps for Continuous Monitoring of Atrial Fibrillation in a Real-World Setting: Pilot Cohort Study
title Validation of Single Centre Pre-Mobile Atrial Fibrillation Apps for Continuous Monitoring of Atrial Fibrillation in a Real-World Setting: Pilot Cohort Study
title_full Validation of Single Centre Pre-Mobile Atrial Fibrillation Apps for Continuous Monitoring of Atrial Fibrillation in a Real-World Setting: Pilot Cohort Study
title_fullStr Validation of Single Centre Pre-Mobile Atrial Fibrillation Apps for Continuous Monitoring of Atrial Fibrillation in a Real-World Setting: Pilot Cohort Study
title_full_unstemmed Validation of Single Centre Pre-Mobile Atrial Fibrillation Apps for Continuous Monitoring of Atrial Fibrillation in a Real-World Setting: Pilot Cohort Study
title_short Validation of Single Centre Pre-Mobile Atrial Fibrillation Apps for Continuous Monitoring of Atrial Fibrillation in a Real-World Setting: Pilot Cohort Study
title_sort validation of single centre pre-mobile atrial fibrillation apps for continuous monitoring of atrial fibrillation in a real-world setting: pilot cohort study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6918204/
https://www.ncbi.nlm.nih.gov/pubmed/31793887
http://dx.doi.org/10.2196/14909
work_keys_str_mv AT zhanghui validationofsinglecentrepremobileatrialfibrillationappsforcontinuousmonitoringofatrialfibrillationinarealworldsettingpilotcohortstudy
AT zhangjie validationofsinglecentrepremobileatrialfibrillationappsforcontinuousmonitoringofatrialfibrillationinarealworldsettingpilotcohortstudy
AT lihongbao validationofsinglecentrepremobileatrialfibrillationappsforcontinuousmonitoringofatrialfibrillationinarealworldsettingpilotcohortstudy
AT chenyixin validationofsinglecentrepremobileatrialfibrillationappsforcontinuousmonitoringofatrialfibrillationinarealworldsettingpilotcohortstudy
AT yangbin validationofsinglecentrepremobileatrialfibrillationappsforcontinuousmonitoringofatrialfibrillationinarealworldsettingpilotcohortstudy
AT guoyutao validationofsinglecentrepremobileatrialfibrillationappsforcontinuousmonitoringofatrialfibrillationinarealworldsettingpilotcohortstudy
AT chenyundai validationofsinglecentrepremobileatrialfibrillationappsforcontinuousmonitoringofatrialfibrillationinarealworldsettingpilotcohortstudy