Cargando…

Assessment of liver fibrosis using 2-dimensional shear wave elastography: a prospective study of intra- and inter-observer repeatability and comparison with point shear wave elastography

PURPOSE: The purpose of this study was to prospectively investigate the intra- and inter-observer repeatability of a new 2-dimensional (2D) shear wave elastography (SWE) technique (S-Shearwave Imaging) for assessing liver fibrosis in chronic liver disease patients, and to compare liver stiffness mea...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoo, Jeongin, Lee, Jeong Min, Joo, Ijin, Yoon, Jeong Hee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Ultrasound in Medicine 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6920625/
https://www.ncbi.nlm.nih.gov/pubmed/31623416
http://dx.doi.org/10.14366/usg.19013
_version_ 1783480984477368320
author Yoo, Jeongin
Lee, Jeong Min
Joo, Ijin
Yoon, Jeong Hee
author_facet Yoo, Jeongin
Lee, Jeong Min
Joo, Ijin
Yoon, Jeong Hee
author_sort Yoo, Jeongin
collection PubMed
description PURPOSE: The purpose of this study was to prospectively investigate the intra- and inter-observer repeatability of a new 2-dimensional (2D) shear wave elastography (SWE) technique (S-Shearwave Imaging) for assessing liver fibrosis in chronic liver disease patients, and to compare liver stiffness measurements (LSMs) made using 2D-SWE with those made using point SWE (pSWE). METHODS: This prospective study received institutional review board approval and informed consent was obtained from all patients. Fifty-three chronic liver disease patients were randomly allocated to group 1 (for intra-observer repeatability [n=33]) or group 2 (for inter-observer repeatability [n=20]). In group 1, two 2D-SWE sessions and one pSWE sessions were performed by one radiologist. In group 2, one 2D-SWE session and one pSWE session were performed by the aforementioned radiologist, and a second 2D-SWE session was performed by another radiologist. The intraclass correlation coefficient (ICC) was used to assess intra- and inter-observer reliability. LSMs obtained using 2D-SWE and pSWE were compared and correlated using the paired t test and Pearson correlation coefficient, respectively. RESULTS: LSMs made using 2D-SWE demonstrated excellent intra- and inter-observer repeatability (ICC, 0.997 [95% confidence interval, 0.994 to 0.999]) and 0.995 [0.988 to 0.998], respectively). LSMs made using 2D-SWE were significantly different from those made using pSWE (2.1±0.6 m/sec vs. 1.9±0.6 m/sec, P<0.001), although a significant correlation existed between the 2D-SWE and pSWE LSMs (rho=0.836, P<0.001). CONCLUSION: S-Shearwave Imaging demonstrated excellent intra- and inter-observer repeatability, and a strong correlation with pSWE measurements of liver stiffness. However, because of the significant difference between LSMs obtained using 2D-SWE and pSWE, these methods should not be used interchangeably.
format Online
Article
Text
id pubmed-6920625
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Korean Society of Ultrasound in Medicine
record_format MEDLINE/PubMed
spelling pubmed-69206252020-01-01 Assessment of liver fibrosis using 2-dimensional shear wave elastography: a prospective study of intra- and inter-observer repeatability and comparison with point shear wave elastography Yoo, Jeongin Lee, Jeong Min Joo, Ijin Yoon, Jeong Hee Ultrasonography Original Article PURPOSE: The purpose of this study was to prospectively investigate the intra- and inter-observer repeatability of a new 2-dimensional (2D) shear wave elastography (SWE) technique (S-Shearwave Imaging) for assessing liver fibrosis in chronic liver disease patients, and to compare liver stiffness measurements (LSMs) made using 2D-SWE with those made using point SWE (pSWE). METHODS: This prospective study received institutional review board approval and informed consent was obtained from all patients. Fifty-three chronic liver disease patients were randomly allocated to group 1 (for intra-observer repeatability [n=33]) or group 2 (for inter-observer repeatability [n=20]). In group 1, two 2D-SWE sessions and one pSWE sessions were performed by one radiologist. In group 2, one 2D-SWE session and one pSWE session were performed by the aforementioned radiologist, and a second 2D-SWE session was performed by another radiologist. The intraclass correlation coefficient (ICC) was used to assess intra- and inter-observer reliability. LSMs obtained using 2D-SWE and pSWE were compared and correlated using the paired t test and Pearson correlation coefficient, respectively. RESULTS: LSMs made using 2D-SWE demonstrated excellent intra- and inter-observer repeatability (ICC, 0.997 [95% confidence interval, 0.994 to 0.999]) and 0.995 [0.988 to 0.998], respectively). LSMs made using 2D-SWE were significantly different from those made using pSWE (2.1±0.6 m/sec vs. 1.9±0.6 m/sec, P<0.001), although a significant correlation existed between the 2D-SWE and pSWE LSMs (rho=0.836, P<0.001). CONCLUSION: S-Shearwave Imaging demonstrated excellent intra- and inter-observer repeatability, and a strong correlation with pSWE measurements of liver stiffness. However, because of the significant difference between LSMs obtained using 2D-SWE and pSWE, these methods should not be used interchangeably. Korean Society of Ultrasound in Medicine 2020-01 2019-06-07 /pmc/articles/PMC6920625/ /pubmed/31623416 http://dx.doi.org/10.14366/usg.19013 Text en Copyright © 2020 Korean Society of Ultrasound in Medicine (KSUM) This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yoo, Jeongin
Lee, Jeong Min
Joo, Ijin
Yoon, Jeong Hee
Assessment of liver fibrosis using 2-dimensional shear wave elastography: a prospective study of intra- and inter-observer repeatability and comparison with point shear wave elastography
title Assessment of liver fibrosis using 2-dimensional shear wave elastography: a prospective study of intra- and inter-observer repeatability and comparison with point shear wave elastography
title_full Assessment of liver fibrosis using 2-dimensional shear wave elastography: a prospective study of intra- and inter-observer repeatability and comparison with point shear wave elastography
title_fullStr Assessment of liver fibrosis using 2-dimensional shear wave elastography: a prospective study of intra- and inter-observer repeatability and comparison with point shear wave elastography
title_full_unstemmed Assessment of liver fibrosis using 2-dimensional shear wave elastography: a prospective study of intra- and inter-observer repeatability and comparison with point shear wave elastography
title_short Assessment of liver fibrosis using 2-dimensional shear wave elastography: a prospective study of intra- and inter-observer repeatability and comparison with point shear wave elastography
title_sort assessment of liver fibrosis using 2-dimensional shear wave elastography: a prospective study of intra- and inter-observer repeatability and comparison with point shear wave elastography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6920625/
https://www.ncbi.nlm.nih.gov/pubmed/31623416
http://dx.doi.org/10.14366/usg.19013
work_keys_str_mv AT yoojeongin assessmentofliverfibrosisusing2dimensionalshearwaveelastographyaprospectivestudyofintraandinterobserverrepeatabilityandcomparisonwithpointshearwaveelastography
AT leejeongmin assessmentofliverfibrosisusing2dimensionalshearwaveelastographyaprospectivestudyofintraandinterobserverrepeatabilityandcomparisonwithpointshearwaveelastography
AT jooijin assessmentofliverfibrosisusing2dimensionalshearwaveelastographyaprospectivestudyofintraandinterobserverrepeatabilityandcomparisonwithpointshearwaveelastography
AT yoonjeonghee assessmentofliverfibrosisusing2dimensionalshearwaveelastographyaprospectivestudyofintraandinterobserverrepeatabilityandcomparisonwithpointshearwaveelastography