Cargando…

Influence of Solvent Composition and Surface Tension on the Signal Intensity of Amino Acids in Electrospray Ionization Mass Spectrometry

The influence of solvent composition and surface tension on the signal intensity of deprotonated molecules [M−H](−) in electrospray ionization mass spectrometry (ESI MS) was evaluated using alanine (Ala), threonine (Thr) and phenylalanine (Phe), which have differing levels of hydrophobicity. The sur...

Descripción completa

Detalles Bibliográficos
Autores principales: Kageyama (Kaneshima), Ami, Motoyama, Akira, Takayama, Mitsuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Mass Spectrometry Society of Japan 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6920628/
https://www.ncbi.nlm.nih.gov/pubmed/32010543
http://dx.doi.org/10.5702/massspectrometry.A0077
_version_ 1783480984963907584
author Kageyama (Kaneshima), Ami
Motoyama, Akira
Takayama, Mitsuo
author_facet Kageyama (Kaneshima), Ami
Motoyama, Akira
Takayama, Mitsuo
author_sort Kageyama (Kaneshima), Ami
collection PubMed
description The influence of solvent composition and surface tension on the signal intensity of deprotonated molecules [M−H](−) in electrospray ionization mass spectrometry (ESI MS) was evaluated using alanine (Ala), threonine (Thr) and phenylalanine (Phe), which have differing levels of hydrophobicity. The surface tension of the ESI solution was varied by changing the ratio of the organic solvents methanol (MeOH) and acetonitrile (MeCN) in water (H(2)O). In ESI MS, the signal intensity of all the amino acids was increased with decreasing surface tension for the two solutions, H(2)O/MeOH and H(2)O/MeCN. The use of H(2)O/MeCN was more favorable for achieving a strong signal for the analytes compared to H(2)O/MeOH. The smaller vaporization enthalpy of MeCN compared to MeOH was proposed as one of the most plausible explanation for this. The order of the signal intensity of amino acids was Phe>Thr>Ala, the same order as their hydrophobicity. It can be practically concluded that the use of solutions with lower surface tensions and lower vaporization enthalpies would result in higher signal intensities in ESI MS.
format Online
Article
Text
id pubmed-6920628
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Mass Spectrometry Society of Japan
record_format MEDLINE/PubMed
spelling pubmed-69206282020-01-31 Influence of Solvent Composition and Surface Tension on the Signal Intensity of Amino Acids in Electrospray Ionization Mass Spectrometry Kageyama (Kaneshima), Ami Motoyama, Akira Takayama, Mitsuo Mass Spectrom (Tokyo) Original Article The influence of solvent composition and surface tension on the signal intensity of deprotonated molecules [M−H](−) in electrospray ionization mass spectrometry (ESI MS) was evaluated using alanine (Ala), threonine (Thr) and phenylalanine (Phe), which have differing levels of hydrophobicity. The surface tension of the ESI solution was varied by changing the ratio of the organic solvents methanol (MeOH) and acetonitrile (MeCN) in water (H(2)O). In ESI MS, the signal intensity of all the amino acids was increased with decreasing surface tension for the two solutions, H(2)O/MeOH and H(2)O/MeCN. The use of H(2)O/MeCN was more favorable for achieving a strong signal for the analytes compared to H(2)O/MeOH. The smaller vaporization enthalpy of MeCN compared to MeOH was proposed as one of the most plausible explanation for this. The order of the signal intensity of amino acids was Phe>Thr>Ala, the same order as their hydrophobicity. It can be practically concluded that the use of solutions with lower surface tensions and lower vaporization enthalpies would result in higher signal intensities in ESI MS. The Mass Spectrometry Society of Japan 2019 2019-11-30 /pmc/articles/PMC6920628/ /pubmed/32010543 http://dx.doi.org/10.5702/massspectrometry.A0077 Text en Copyright © 2019 Ami Kageyama (Kaneshima), Akira Motoyama, and Mitsuo Takayama. http://creativecommons.org/licenses/by/2.5/ This is an open access article distributed under the terms of Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Article
Kageyama (Kaneshima), Ami
Motoyama, Akira
Takayama, Mitsuo
Influence of Solvent Composition and Surface Tension on the Signal Intensity of Amino Acids in Electrospray Ionization Mass Spectrometry
title Influence of Solvent Composition and Surface Tension on the Signal Intensity of Amino Acids in Electrospray Ionization Mass Spectrometry
title_full Influence of Solvent Composition and Surface Tension on the Signal Intensity of Amino Acids in Electrospray Ionization Mass Spectrometry
title_fullStr Influence of Solvent Composition and Surface Tension on the Signal Intensity of Amino Acids in Electrospray Ionization Mass Spectrometry
title_full_unstemmed Influence of Solvent Composition and Surface Tension on the Signal Intensity of Amino Acids in Electrospray Ionization Mass Spectrometry
title_short Influence of Solvent Composition and Surface Tension on the Signal Intensity of Amino Acids in Electrospray Ionization Mass Spectrometry
title_sort influence of solvent composition and surface tension on the signal intensity of amino acids in electrospray ionization mass spectrometry
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6920628/
https://www.ncbi.nlm.nih.gov/pubmed/32010543
http://dx.doi.org/10.5702/massspectrometry.A0077
work_keys_str_mv AT kageyamakaneshimaami influenceofsolventcompositionandsurfacetensiononthesignalintensityofaminoacidsinelectrosprayionizationmassspectrometry
AT motoyamaakira influenceofsolventcompositionandsurfacetensiononthesignalintensityofaminoacidsinelectrosprayionizationmassspectrometry
AT takayamamitsuo influenceofsolventcompositionandsurfacetensiononthesignalintensityofaminoacidsinelectrosprayionizationmassspectrometry