Cargando…

Effects on hip stress following sacroiliac joint fixation: A finite element study

For those patients who suffer from low back pain generated by the sacroiliac (SI) joint, fusion of the SI joint has proven to be an effective means of stabilizing it and reducing pain. Though it has shown promise, SI joint fusion raises clinical questions regarding its effect on neighboring joints s...

Descripción completa

Detalles Bibliográficos
Autores principales: Joukar, Amin, Chande, Ruchi D., Carpenter, R. Dana, Lindsey, Derek P., Erbulut, Deniz U., Yerby, Scott A., Duhon, Bradley, Goel, Vijay K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6920688/
https://www.ncbi.nlm.nih.gov/pubmed/31891117
http://dx.doi.org/10.1002/jsp2.1067
_version_ 1783480989934157824
author Joukar, Amin
Chande, Ruchi D.
Carpenter, R. Dana
Lindsey, Derek P.
Erbulut, Deniz U.
Yerby, Scott A.
Duhon, Bradley
Goel, Vijay K.
author_facet Joukar, Amin
Chande, Ruchi D.
Carpenter, R. Dana
Lindsey, Derek P.
Erbulut, Deniz U.
Yerby, Scott A.
Duhon, Bradley
Goel, Vijay K.
author_sort Joukar, Amin
collection PubMed
description For those patients who suffer from low back pain generated by the sacroiliac (SI) joint, fusion of the SI joint has proven to be an effective means of stabilizing it and reducing pain. Though it has shown promise, SI joint fusion raises clinical questions regarding its effect on neighboring joints such as the hip. As such, the purpose of this study was to determine the effects of SI joint fixation on the hip. A finite element spine‐sacroiliac‐hip (SSIH) model was developed and its functionality was verified against SI joint range of motion (ROM) and hip contact stress, respectively. The intact model was fixed in double leg stance at the distal femora, and loading was applied at the lumbar spine to simulate stance, flexion, extension, right and left lateral bending, and right and left axial rotation. Functionality was confirmed by measuring and comparing SI joint ROM and contact stress and area at the hip with data from the literature. Following verification of the intact SSIH model, both unilateral and bilateral SI joint fixation were modeled; hip contact stress and area were compared to the intact state. Average hip contact stress was ~2 MPa, with most motions resulting in changes less than 5% relative to intact; contact area changed less than 10% for any motion. Clinical significance: these results demonstrated that SI joint fixation with triangular titanium implants imparted little change in stress at the hip, which suggests that the risk of developing adjacent segment disease is likely low. Future clinical studies may be executed to confirm the results of this computational study.
format Online
Article
Text
id pubmed-6920688
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-69206882019-12-30 Effects on hip stress following sacroiliac joint fixation: A finite element study Joukar, Amin Chande, Ruchi D. Carpenter, R. Dana Lindsey, Derek P. Erbulut, Deniz U. Yerby, Scott A. Duhon, Bradley Goel, Vijay K. JOR Spine Research Articles For those patients who suffer from low back pain generated by the sacroiliac (SI) joint, fusion of the SI joint has proven to be an effective means of stabilizing it and reducing pain. Though it has shown promise, SI joint fusion raises clinical questions regarding its effect on neighboring joints such as the hip. As such, the purpose of this study was to determine the effects of SI joint fixation on the hip. A finite element spine‐sacroiliac‐hip (SSIH) model was developed and its functionality was verified against SI joint range of motion (ROM) and hip contact stress, respectively. The intact model was fixed in double leg stance at the distal femora, and loading was applied at the lumbar spine to simulate stance, flexion, extension, right and left lateral bending, and right and left axial rotation. Functionality was confirmed by measuring and comparing SI joint ROM and contact stress and area at the hip with data from the literature. Following verification of the intact SSIH model, both unilateral and bilateral SI joint fixation were modeled; hip contact stress and area were compared to the intact state. Average hip contact stress was ~2 MPa, with most motions resulting in changes less than 5% relative to intact; contact area changed less than 10% for any motion. Clinical significance: these results demonstrated that SI joint fixation with triangular titanium implants imparted little change in stress at the hip, which suggests that the risk of developing adjacent segment disease is likely low. Future clinical studies may be executed to confirm the results of this computational study. John Wiley & Sons, Inc. 2019-10-20 /pmc/articles/PMC6920688/ /pubmed/31891117 http://dx.doi.org/10.1002/jsp2.1067 Text en © 2019 The Authors. JOR Spine published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Joukar, Amin
Chande, Ruchi D.
Carpenter, R. Dana
Lindsey, Derek P.
Erbulut, Deniz U.
Yerby, Scott A.
Duhon, Bradley
Goel, Vijay K.
Effects on hip stress following sacroiliac joint fixation: A finite element study
title Effects on hip stress following sacroiliac joint fixation: A finite element study
title_full Effects on hip stress following sacroiliac joint fixation: A finite element study
title_fullStr Effects on hip stress following sacroiliac joint fixation: A finite element study
title_full_unstemmed Effects on hip stress following sacroiliac joint fixation: A finite element study
title_short Effects on hip stress following sacroiliac joint fixation: A finite element study
title_sort effects on hip stress following sacroiliac joint fixation: a finite element study
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6920688/
https://www.ncbi.nlm.nih.gov/pubmed/31891117
http://dx.doi.org/10.1002/jsp2.1067
work_keys_str_mv AT joukaramin effectsonhipstressfollowingsacroiliacjointfixationafiniteelementstudy
AT chanderuchid effectsonhipstressfollowingsacroiliacjointfixationafiniteelementstudy
AT carpenterrdana effectsonhipstressfollowingsacroiliacjointfixationafiniteelementstudy
AT lindseyderekp effectsonhipstressfollowingsacroiliacjointfixationafiniteelementstudy
AT erbulutdenizu effectsonhipstressfollowingsacroiliacjointfixationafiniteelementstudy
AT yerbyscotta effectsonhipstressfollowingsacroiliacjointfixationafiniteelementstudy
AT duhonbradley effectsonhipstressfollowingsacroiliacjointfixationafiniteelementstudy
AT goelvijayk effectsonhipstressfollowingsacroiliacjointfixationafiniteelementstudy