Cargando…

Influence of time on primary stability of dental implants placed with osteotomes due to the elastic properties of peri-implant bone

BACKGROUND/PURPOSE: The use of osteotomes as a technique for densification and expansion of the residual ridge is one of the most widely used procedures to achieve adequate peri-implant bone quantity and density. The aim of this study was to evaluate the influence of time and the elastic deformation...

Descripción completa

Detalles Bibliográficos
Autores principales: Pérez-Pevida, Esteban, Brizuela-Velasco, Aritza, Chávarri-Prado, David, Diéguez-Pereira, Markel, Jiménez-Garrudo, Antonio, Montalbán-Vadillo, Oier, Viteri-Agustín, Iratxe, Estrada-Martínez, Alejandro, Santamaría-Arrieta, Gorka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Association for Dental Sciences of the Republic of China 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6921116/
https://www.ncbi.nlm.nih.gov/pubmed/31890122
http://dx.doi.org/10.1016/j.jds.2019.04.004
_version_ 1783481088716308480
author Pérez-Pevida, Esteban
Brizuela-Velasco, Aritza
Chávarri-Prado, David
Diéguez-Pereira, Markel
Jiménez-Garrudo, Antonio
Montalbán-Vadillo, Oier
Viteri-Agustín, Iratxe
Estrada-Martínez, Alejandro
Santamaría-Arrieta, Gorka
author_facet Pérez-Pevida, Esteban
Brizuela-Velasco, Aritza
Chávarri-Prado, David
Diéguez-Pereira, Markel
Jiménez-Garrudo, Antonio
Montalbán-Vadillo, Oier
Viteri-Agustín, Iratxe
Estrada-Martínez, Alejandro
Santamaría-Arrieta, Gorka
author_sort Pérez-Pevida, Esteban
collection PubMed
description BACKGROUND/PURPOSE: The use of osteotomes as a technique for densification and expansion of the residual ridge is one of the most widely used procedures to achieve adequate peri-implant bone quantity and density. The aim of this study was to evaluate the influence of time and the elastic deformation of peri-implant bone in the primary stability of implants placed using osteotomes. MATERIALS AND METHODS: In each of 10 fresh fragments of cow rib, two implants were placed using osteotomes. The insertion torque and initial implant stability quotient (ISQ) values were measured. In the control implants, the immediate removal torque was measured, while in the test implants, after 15 min of placement, ISQ values were measured again, and the removal torque was measured. RESULTS: There were significant differences between the ISQ values and between the insertion torque and removal torque at 15 min. The ISQ values (perpendicular/parallel) increased between the initial moment (64.4 ± 9/70.3 ± 5.9) and 15 min (66/71.4 ± 6.4). The removal torque at 15 min (12.4 ± 5.8) was lower than the insertion torque (15.9 ± 5.9). Compression of the trabeculae in contact with the implant placed using osteotomes was observed, as well as a greater number of trabecular fractures in the implants placed using conventional drilling. CONCLUSION: There is an increase in ISQ values of dental implants placed using osteotomes after 15 min of placement.
format Online
Article
Text
id pubmed-6921116
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Association for Dental Sciences of the Republic of China
record_format MEDLINE/PubMed
spelling pubmed-69211162019-12-30 Influence of time on primary stability of dental implants placed with osteotomes due to the elastic properties of peri-implant bone Pérez-Pevida, Esteban Brizuela-Velasco, Aritza Chávarri-Prado, David Diéguez-Pereira, Markel Jiménez-Garrudo, Antonio Montalbán-Vadillo, Oier Viteri-Agustín, Iratxe Estrada-Martínez, Alejandro Santamaría-Arrieta, Gorka J Dent Sci Original Article BACKGROUND/PURPOSE: The use of osteotomes as a technique for densification and expansion of the residual ridge is one of the most widely used procedures to achieve adequate peri-implant bone quantity and density. The aim of this study was to evaluate the influence of time and the elastic deformation of peri-implant bone in the primary stability of implants placed using osteotomes. MATERIALS AND METHODS: In each of 10 fresh fragments of cow rib, two implants were placed using osteotomes. The insertion torque and initial implant stability quotient (ISQ) values were measured. In the control implants, the immediate removal torque was measured, while in the test implants, after 15 min of placement, ISQ values were measured again, and the removal torque was measured. RESULTS: There were significant differences between the ISQ values and between the insertion torque and removal torque at 15 min. The ISQ values (perpendicular/parallel) increased between the initial moment (64.4 ± 9/70.3 ± 5.9) and 15 min (66/71.4 ± 6.4). The removal torque at 15 min (12.4 ± 5.8) was lower than the insertion torque (15.9 ± 5.9). Compression of the trabeculae in contact with the implant placed using osteotomes was observed, as well as a greater number of trabecular fractures in the implants placed using conventional drilling. CONCLUSION: There is an increase in ISQ values of dental implants placed using osteotomes after 15 min of placement. Association for Dental Sciences of the Republic of China 2019-12 2019-05-21 /pmc/articles/PMC6921116/ /pubmed/31890122 http://dx.doi.org/10.1016/j.jds.2019.04.004 Text en © 2019 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Pérez-Pevida, Esteban
Brizuela-Velasco, Aritza
Chávarri-Prado, David
Diéguez-Pereira, Markel
Jiménez-Garrudo, Antonio
Montalbán-Vadillo, Oier
Viteri-Agustín, Iratxe
Estrada-Martínez, Alejandro
Santamaría-Arrieta, Gorka
Influence of time on primary stability of dental implants placed with osteotomes due to the elastic properties of peri-implant bone
title Influence of time on primary stability of dental implants placed with osteotomes due to the elastic properties of peri-implant bone
title_full Influence of time on primary stability of dental implants placed with osteotomes due to the elastic properties of peri-implant bone
title_fullStr Influence of time on primary stability of dental implants placed with osteotomes due to the elastic properties of peri-implant bone
title_full_unstemmed Influence of time on primary stability of dental implants placed with osteotomes due to the elastic properties of peri-implant bone
title_short Influence of time on primary stability of dental implants placed with osteotomes due to the elastic properties of peri-implant bone
title_sort influence of time on primary stability of dental implants placed with osteotomes due to the elastic properties of peri-implant bone
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6921116/
https://www.ncbi.nlm.nih.gov/pubmed/31890122
http://dx.doi.org/10.1016/j.jds.2019.04.004
work_keys_str_mv AT perezpevidaesteban influenceoftimeonprimarystabilityofdentalimplantsplacedwithosteotomesduetotheelasticpropertiesofperiimplantbone
AT brizuelavelascoaritza influenceoftimeonprimarystabilityofdentalimplantsplacedwithosteotomesduetotheelasticpropertiesofperiimplantbone
AT chavarripradodavid influenceoftimeonprimarystabilityofdentalimplantsplacedwithosteotomesduetotheelasticpropertiesofperiimplantbone
AT dieguezpereiramarkel influenceoftimeonprimarystabilityofdentalimplantsplacedwithosteotomesduetotheelasticpropertiesofperiimplantbone
AT jimenezgarrudoantonio influenceoftimeonprimarystabilityofdentalimplantsplacedwithosteotomesduetotheelasticpropertiesofperiimplantbone
AT montalbanvadillooier influenceoftimeonprimarystabilityofdentalimplantsplacedwithosteotomesduetotheelasticpropertiesofperiimplantbone
AT viteriagustiniratxe influenceoftimeonprimarystabilityofdentalimplantsplacedwithosteotomesduetotheelasticpropertiesofperiimplantbone
AT estradamartinezalejandro influenceoftimeonprimarystabilityofdentalimplantsplacedwithosteotomesduetotheelasticpropertiesofperiimplantbone
AT santamariaarrietagorka influenceoftimeonprimarystabilityofdentalimplantsplacedwithosteotomesduetotheelasticpropertiesofperiimplantbone