Cargando…

Added value of ultrasonography and Tc-99m MIBI SPECT/CT combined protocol in preoperative evaluation of parathyroid adenoma

PURPOSE: Evaluating the diagnostic performance of combined protocol of ultrasonography and Tc-99 m MIBI SPECT/CT in preoperative depiction and localization of parathyroid adenoma. METHODS AND MATERIALS: 60 patients were enrolled in this retrospective study who had primary hyperparathyroidism and par...

Descripción completa

Detalles Bibliográficos
Autores principales: Tawfik, Ahmed Ibrahim, Kamr, Wael Hamza, Mahmoud, Walaa, Abo Shady, Islam Ahmed, Mohamed, Mohamed Hosny
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6921373/
https://www.ncbi.nlm.nih.gov/pubmed/31886318
http://dx.doi.org/10.1016/j.ejro.2019.11.002
_version_ 1783481146899693568
author Tawfik, Ahmed Ibrahim
Kamr, Wael Hamza
Mahmoud, Walaa
Abo Shady, Islam Ahmed
Mohamed, Mohamed Hosny
author_facet Tawfik, Ahmed Ibrahim
Kamr, Wael Hamza
Mahmoud, Walaa
Abo Shady, Islam Ahmed
Mohamed, Mohamed Hosny
author_sort Tawfik, Ahmed Ibrahim
collection PubMed
description PURPOSE: Evaluating the diagnostic performance of combined protocol of ultrasonography and Tc-99 m MIBI SPECT/CT in preoperative depiction and localization of parathyroid adenoma. METHODS AND MATERIALS: 60 patients were enrolled in this retrospective study who had primary hyperparathyroidism and parathyroidectomy for parathyroid adenoma, all of them underwent ultrasonography examination of parathyroid gland and MIBI SPECT/CT for exact pre-operative localization of parathyroid adenoma, surgical and pathological results were used as standard reference then sensitivity, specificity and accuracy for each modalility and for combined protocol of both modalities was calculated. RESULTS: The sensitivity, specificity and accuracy were highest with combined protocol of ultrasonography and MIBI-SPECT/CT (87 %), (71 %) and (85 %) respectively and lowest sensitivity, specificity and accuracy with ultrasonography alone (76 %), (63 %) and (73 %) respectively while (83 %), (66 %) and (80 %) with MIBI-SPECT/CT alone. CONCLUSION: Concomitant use of ultrasonography and MIBI SPECT/CT is highly recommended for better preoperative depiction and localization of parathyroid adenoma.
format Online
Article
Text
id pubmed-6921373
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-69213732019-12-27 Added value of ultrasonography and Tc-99m MIBI SPECT/CT combined protocol in preoperative evaluation of parathyroid adenoma Tawfik, Ahmed Ibrahim Kamr, Wael Hamza Mahmoud, Walaa Abo Shady, Islam Ahmed Mohamed, Mohamed Hosny Eur J Radiol Open Article PURPOSE: Evaluating the diagnostic performance of combined protocol of ultrasonography and Tc-99 m MIBI SPECT/CT in preoperative depiction and localization of parathyroid adenoma. METHODS AND MATERIALS: 60 patients were enrolled in this retrospective study who had primary hyperparathyroidism and parathyroidectomy for parathyroid adenoma, all of them underwent ultrasonography examination of parathyroid gland and MIBI SPECT/CT for exact pre-operative localization of parathyroid adenoma, surgical and pathological results were used as standard reference then sensitivity, specificity and accuracy for each modalility and for combined protocol of both modalities was calculated. RESULTS: The sensitivity, specificity and accuracy were highest with combined protocol of ultrasonography and MIBI-SPECT/CT (87 %), (71 %) and (85 %) respectively and lowest sensitivity, specificity and accuracy with ultrasonography alone (76 %), (63 %) and (73 %) respectively while (83 %), (66 %) and (80 %) with MIBI-SPECT/CT alone. CONCLUSION: Concomitant use of ultrasonography and MIBI SPECT/CT is highly recommended for better preoperative depiction and localization of parathyroid adenoma. Elsevier 2019-11-15 /pmc/articles/PMC6921373/ /pubmed/31886318 http://dx.doi.org/10.1016/j.ejro.2019.11.002 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Tawfik, Ahmed Ibrahim
Kamr, Wael Hamza
Mahmoud, Walaa
Abo Shady, Islam Ahmed
Mohamed, Mohamed Hosny
Added value of ultrasonography and Tc-99m MIBI SPECT/CT combined protocol in preoperative evaluation of parathyroid adenoma
title Added value of ultrasonography and Tc-99m MIBI SPECT/CT combined protocol in preoperative evaluation of parathyroid adenoma
title_full Added value of ultrasonography and Tc-99m MIBI SPECT/CT combined protocol in preoperative evaluation of parathyroid adenoma
title_fullStr Added value of ultrasonography and Tc-99m MIBI SPECT/CT combined protocol in preoperative evaluation of parathyroid adenoma
title_full_unstemmed Added value of ultrasonography and Tc-99m MIBI SPECT/CT combined protocol in preoperative evaluation of parathyroid adenoma
title_short Added value of ultrasonography and Tc-99m MIBI SPECT/CT combined protocol in preoperative evaluation of parathyroid adenoma
title_sort added value of ultrasonography and tc-99m mibi spect/ct combined protocol in preoperative evaluation of parathyroid adenoma
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6921373/
https://www.ncbi.nlm.nih.gov/pubmed/31886318
http://dx.doi.org/10.1016/j.ejro.2019.11.002
work_keys_str_mv AT tawfikahmedibrahim addedvalueofultrasonographyandtc99mmibispectctcombinedprotocolinpreoperativeevaluationofparathyroidadenoma
AT kamrwaelhamza addedvalueofultrasonographyandtc99mmibispectctcombinedprotocolinpreoperativeevaluationofparathyroidadenoma
AT mahmoudwalaa addedvalueofultrasonographyandtc99mmibispectctcombinedprotocolinpreoperativeevaluationofparathyroidadenoma
AT aboshadyislamahmed addedvalueofultrasonographyandtc99mmibispectctcombinedprotocolinpreoperativeevaluationofparathyroidadenoma
AT mohamedmohamedhosny addedvalueofultrasonographyandtc99mmibispectctcombinedprotocolinpreoperativeevaluationofparathyroidadenoma