Cargando…
Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls
AIMS: To compare the biomechanically corrected intraocular pressure (IOP) estimate (bIOP) provided by the Corvis-ST with Goldmann applanation tonometry (GAT-IOP) in patients with high-tension and normal-tension primary open-angle glaucoma (POAG; HTG and NTG), ocular hypertension (OHT) and controls....
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6922012/ https://www.ncbi.nlm.nih.gov/pubmed/30923134 http://dx.doi.org/10.1136/bjophthalmol-2018-313493 |
_version_ | 1783481265835474944 |
---|---|
author | Vinciguerra, Riccardo Rehman, Salwah Vallabh, Neeru A Batterbury, Mark Czanner, Gabriela Choudhary, Anshoo Cheeseman, Robert Elsheikh, Ahmed Willoughby, Colin E |
author_facet | Vinciguerra, Riccardo Rehman, Salwah Vallabh, Neeru A Batterbury, Mark Czanner, Gabriela Choudhary, Anshoo Cheeseman, Robert Elsheikh, Ahmed Willoughby, Colin E |
author_sort | Vinciguerra, Riccardo |
collection | PubMed |
description | AIMS: To compare the biomechanically corrected intraocular pressure (IOP) estimate (bIOP) provided by the Corvis-ST with Goldmann applanation tonometry (GAT-IOP) in patients with high-tension and normal-tension primary open-angle glaucoma (POAG; HTG and NTG), ocular hypertension (OHT) and controls. Moreover, we compared dynamic corneal response parameters (DCRs) of the Corvis-ST in POAG, OHT and controls, evaluated the correlation between global visual field parameters mean deviation and pattern SD (MD and PSD) and DCRs in the POAG group. METHODS: 156 eyes of 156 patients were included in this prospective, single-centre, observational study, namely 41 HTG and 33 NTG, 45 OHT cases and 37 controls. Central corneal thickness (CCT), GAT-IOP and bIOP were measured, GAT-IOP was also adjusted for CCT (GATAdj). DCRs provided by Corvis-ST were evaluated, MD and PSD were recorded by 24–2 full-threshold visual field. To evaluate the difference in DCRs between OHT, HTG and NTG, a general linear model was used with sex, medications and group as fixed factors and bIOP and age as covariates. RESULTS: There was a significant difference between GAT-IOP, GATAdj and bIOP in NTG and HTG, OHT and controls. NTG corneas were significantly softer and more deformable compared with controls, OHT and HTG as demonstrated by significantly lower values of stiffness parameters A1 and highest concavity and higher values of inverse concave radius (all p<0.05). There was a significant correlation (p<0.05) between MD, PSD and many DCRs with POAG patients with softer or more compliant corneas more likely to show visual field defects. CONCLUSIONS: Corneal biomechanics might be a significant confounding factor for IOP measurement that should be considered in clinical decision-making. The abnormality of corneal biomechanics in NTG and the significant correlation with visual field parameters might suggest a new risk factor for the development or progression of NTG. |
format | Online Article Text |
id | pubmed-6922012 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-69220122020-01-02 Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls Vinciguerra, Riccardo Rehman, Salwah Vallabh, Neeru A Batterbury, Mark Czanner, Gabriela Choudhary, Anshoo Cheeseman, Robert Elsheikh, Ahmed Willoughby, Colin E Br J Ophthalmol Clinical Science AIMS: To compare the biomechanically corrected intraocular pressure (IOP) estimate (bIOP) provided by the Corvis-ST with Goldmann applanation tonometry (GAT-IOP) in patients with high-tension and normal-tension primary open-angle glaucoma (POAG; HTG and NTG), ocular hypertension (OHT) and controls. Moreover, we compared dynamic corneal response parameters (DCRs) of the Corvis-ST in POAG, OHT and controls, evaluated the correlation between global visual field parameters mean deviation and pattern SD (MD and PSD) and DCRs in the POAG group. METHODS: 156 eyes of 156 patients were included in this prospective, single-centre, observational study, namely 41 HTG and 33 NTG, 45 OHT cases and 37 controls. Central corneal thickness (CCT), GAT-IOP and bIOP were measured, GAT-IOP was also adjusted for CCT (GATAdj). DCRs provided by Corvis-ST were evaluated, MD and PSD were recorded by 24–2 full-threshold visual field. To evaluate the difference in DCRs between OHT, HTG and NTG, a general linear model was used with sex, medications and group as fixed factors and bIOP and age as covariates. RESULTS: There was a significant difference between GAT-IOP, GATAdj and bIOP in NTG and HTG, OHT and controls. NTG corneas were significantly softer and more deformable compared with controls, OHT and HTG as demonstrated by significantly lower values of stiffness parameters A1 and highest concavity and higher values of inverse concave radius (all p<0.05). There was a significant correlation (p<0.05) between MD, PSD and many DCRs with POAG patients with softer or more compliant corneas more likely to show visual field defects. CONCLUSIONS: Corneal biomechanics might be a significant confounding factor for IOP measurement that should be considered in clinical decision-making. The abnormality of corneal biomechanics in NTG and the significant correlation with visual field parameters might suggest a new risk factor for the development or progression of NTG. BMJ Publishing Group 2020-01 2019-03-28 /pmc/articles/PMC6922012/ /pubmed/30923134 http://dx.doi.org/10.1136/bjophthalmol-2018-313493 Text en © Author(s) (or their employer(s)) 2020. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Clinical Science Vinciguerra, Riccardo Rehman, Salwah Vallabh, Neeru A Batterbury, Mark Czanner, Gabriela Choudhary, Anshoo Cheeseman, Robert Elsheikh, Ahmed Willoughby, Colin E Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls |
title | Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls |
title_full | Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls |
title_fullStr | Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls |
title_full_unstemmed | Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls |
title_short | Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls |
title_sort | corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls |
topic | Clinical Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6922012/ https://www.ncbi.nlm.nih.gov/pubmed/30923134 http://dx.doi.org/10.1136/bjophthalmol-2018-313493 |
work_keys_str_mv | AT vinciguerrariccardo cornealbiomechanicsandbiomechanicallycorrectedintraocularpressureinprimaryopenangleglaucomaocularhypertensionandcontrols AT rehmansalwah cornealbiomechanicsandbiomechanicallycorrectedintraocularpressureinprimaryopenangleglaucomaocularhypertensionandcontrols AT vallabhneerua cornealbiomechanicsandbiomechanicallycorrectedintraocularpressureinprimaryopenangleglaucomaocularhypertensionandcontrols AT batterburymark cornealbiomechanicsandbiomechanicallycorrectedintraocularpressureinprimaryopenangleglaucomaocularhypertensionandcontrols AT czannergabriela cornealbiomechanicsandbiomechanicallycorrectedintraocularpressureinprimaryopenangleglaucomaocularhypertensionandcontrols AT choudharyanshoo cornealbiomechanicsandbiomechanicallycorrectedintraocularpressureinprimaryopenangleglaucomaocularhypertensionandcontrols AT cheesemanrobert cornealbiomechanicsandbiomechanicallycorrectedintraocularpressureinprimaryopenangleglaucomaocularhypertensionandcontrols AT elsheikhahmed cornealbiomechanicsandbiomechanicallycorrectedintraocularpressureinprimaryopenangleglaucomaocularhypertensionandcontrols AT willoughbycoline cornealbiomechanicsandbiomechanicallycorrectedintraocularpressureinprimaryopenangleglaucomaocularhypertensionandcontrols |