Cargando…

Test-retest reliability of the twenty-five-hole peg test in patients who had a stroke

OBJECTIVES: Weaknesses of the nine-hole peg test include high floor effects and a result that might be difficult to interpret. In the twenty-five-hole peg test (TFHPT), the larger number of available pegs allows for the straightforward counting of the number of pegs inserted as the result. The TFHPT...

Descripción completa

Detalles Bibliográficos
Autores principales: Granström, Fredrik, Hedlund, Mattias, Lindström, Britta, Eriksson, Staffan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6924848/
https://www.ncbi.nlm.nih.gov/pubmed/31831545
http://dx.doi.org/10.1136/bmjopen-2019-032560
_version_ 1783481803484430336
author Granström, Fredrik
Hedlund, Mattias
Lindström, Britta
Eriksson, Staffan
author_facet Granström, Fredrik
Hedlund, Mattias
Lindström, Britta
Eriksson, Staffan
author_sort Granström, Fredrik
collection PubMed
description OBJECTIVES: Weaknesses of the nine-hole peg test include high floor effects and a result that might be difficult to interpret. In the twenty-five-hole peg test (TFHPT), the larger number of available pegs allows for the straightforward counting of the number of pegs inserted as the result. The TFHPT provides a comprehensible result and low floor effects. The objective was to assess the test-retest reliability of the TFHPT when testing persons with stroke. A particular focus was placed on the absolute reliability, as quantified by the smallest real difference (SRD). Complementary aims were to investigate possible implications for how the TFHPT should be used and for how the SRD of the TFHPT performance should be expressed. DESIGN: This study employed a test-retest design including three trials. The pause between trials was approximately 10–120 s. PARTICIPANTS, SETTING AND OUTCOME MEASURE: Thirty-one participants who had suffered a stroke were recruited from a group designated for constraint-induced movement therapy at outpatient clinics. The TFHPT result was expressed as the number of pegs inserted. METHODS: Absolute reliability was quantified by the SRD, including random and systematic error for a single trial, SRD(2.1), and for an average of three trials, SRD(2.3). For the SRD measures, the corresponding SRD percentage (SRD%) measure was also reported. RESULTS: The differences in the number of pegs necessary to detect a change in the TFHPT for SRD(2.1) and SRD(2.3) were 4.0 and 2.3, respectively. The corresponding SRD% values for SRD(2.1) and SRD(2.3) were 36.5% and 21.3%, respectively. CONCLUSIONS: The smallest change that can be detected in the TFHPT should be just above two pegs for a test procedure including an average of three trials. The use of an average of three trials compared with a single trial substantially reduces the measurement error. TRIAL REGISTRATION NUMBER: ISRCTN registry, reference number ISRCTN24868616.
format Online
Article
Text
id pubmed-6924848
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-69248482020-01-03 Test-retest reliability of the twenty-five-hole peg test in patients who had a stroke Granström, Fredrik Hedlund, Mattias Lindström, Britta Eriksson, Staffan BMJ Open Rehabilitation Medicine OBJECTIVES: Weaknesses of the nine-hole peg test include high floor effects and a result that might be difficult to interpret. In the twenty-five-hole peg test (TFHPT), the larger number of available pegs allows for the straightforward counting of the number of pegs inserted as the result. The TFHPT provides a comprehensible result and low floor effects. The objective was to assess the test-retest reliability of the TFHPT when testing persons with stroke. A particular focus was placed on the absolute reliability, as quantified by the smallest real difference (SRD). Complementary aims were to investigate possible implications for how the TFHPT should be used and for how the SRD of the TFHPT performance should be expressed. DESIGN: This study employed a test-retest design including three trials. The pause between trials was approximately 10–120 s. PARTICIPANTS, SETTING AND OUTCOME MEASURE: Thirty-one participants who had suffered a stroke were recruited from a group designated for constraint-induced movement therapy at outpatient clinics. The TFHPT result was expressed as the number of pegs inserted. METHODS: Absolute reliability was quantified by the SRD, including random and systematic error for a single trial, SRD(2.1), and for an average of three trials, SRD(2.3). For the SRD measures, the corresponding SRD percentage (SRD%) measure was also reported. RESULTS: The differences in the number of pegs necessary to detect a change in the TFHPT for SRD(2.1) and SRD(2.3) were 4.0 and 2.3, respectively. The corresponding SRD% values for SRD(2.1) and SRD(2.3) were 36.5% and 21.3%, respectively. CONCLUSIONS: The smallest change that can be detected in the TFHPT should be just above two pegs for a test procedure including an average of three trials. The use of an average of three trials compared with a single trial substantially reduces the measurement error. TRIAL REGISTRATION NUMBER: ISRCTN registry, reference number ISRCTN24868616. BMJ Publishing Group 2019-12-11 /pmc/articles/PMC6924848/ /pubmed/31831545 http://dx.doi.org/10.1136/bmjopen-2019-032560 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Rehabilitation Medicine
Granström, Fredrik
Hedlund, Mattias
Lindström, Britta
Eriksson, Staffan
Test-retest reliability of the twenty-five-hole peg test in patients who had a stroke
title Test-retest reliability of the twenty-five-hole peg test in patients who had a stroke
title_full Test-retest reliability of the twenty-five-hole peg test in patients who had a stroke
title_fullStr Test-retest reliability of the twenty-five-hole peg test in patients who had a stroke
title_full_unstemmed Test-retest reliability of the twenty-five-hole peg test in patients who had a stroke
title_short Test-retest reliability of the twenty-five-hole peg test in patients who had a stroke
title_sort test-retest reliability of the twenty-five-hole peg test in patients who had a stroke
topic Rehabilitation Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6924848/
https://www.ncbi.nlm.nih.gov/pubmed/31831545
http://dx.doi.org/10.1136/bmjopen-2019-032560
work_keys_str_mv AT granstromfredrik testretestreliabilityofthetwentyfiveholepegtestinpatientswhohadastroke
AT hedlundmattias testretestreliabilityofthetwentyfiveholepegtestinpatientswhohadastroke
AT lindstrombritta testretestreliabilityofthetwentyfiveholepegtestinpatientswhohadastroke
AT erikssonstaffan testretestreliabilityofthetwentyfiveholepegtestinpatientswhohadastroke