Cargando…
Single cell correlation analysis of liquid and solid biopsies in metastatic colorectal cancer
As cancer care is transitioning to personalized therapies with necessary complementary or companion biomarkers there is significant interest in determining to what extent non-invasive liquid biopsies reflect the gold standard solid biopsy. We have established an approach for measuring patient-specif...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Impact Journals LLC
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6925029/ https://www.ncbi.nlm.nih.gov/pubmed/31903162 http://dx.doi.org/10.18632/oncotarget.27271 |
_version_ | 1783481832448196608 |
---|---|
author | Gerdtsson, Anna S. Thiele, Jana-Aletta Shishido, Stephanie N. Zheng, Serena Schaffer, Randolph Bethel, Kelly Curley, Steven Lenz, Heinz-Josef Hanna, Diana L. Nieva, Jorge Kolatkar, Anand Ruiz, Carmen Rodriguez-Lee, Mariam Oakley III, Gerard J. Lee, Jerry S.H. Hicks, James Kuhn, Peter |
author_facet | Gerdtsson, Anna S. Thiele, Jana-Aletta Shishido, Stephanie N. Zheng, Serena Schaffer, Randolph Bethel, Kelly Curley, Steven Lenz, Heinz-Josef Hanna, Diana L. Nieva, Jorge Kolatkar, Anand Ruiz, Carmen Rodriguez-Lee, Mariam Oakley III, Gerard J. Lee, Jerry S.H. Hicks, James Kuhn, Peter |
author_sort | Gerdtsson, Anna S. |
collection | PubMed |
description | As cancer care is transitioning to personalized therapies with necessary complementary or companion biomarkers there is significant interest in determining to what extent non-invasive liquid biopsies reflect the gold standard solid biopsy. We have established an approach for measuring patient-specific circulating and solid cell concordance by introducing tumor touch preparations to the High-Definition Single Cell Analysis workflow for high-resolution cytomorphometric characterization of metastatic colorectal cancer (mCRC). Subgroups of cells based on size, shape and protein expression were identified in both liquid and solid biopsies, which overall displayed high inter- and intra- patient pleomorphism at the single-cell level of analysis. Concordance of liquid and solid biopsies was patient-dependent and between 0.1-0.9. Morphometric variables displayed particularly high correlation, suggesting that circulating cells do not represent distinct subpopulations from the solid tumor. This was further substantiated by significant decrease in concentration of circulating cells after mCRC resection. Combined with the association of circulating cells with tumor burden and necrosis of hepatic lesions, our overall findings demonstrate that liquid biopsy cells can be informative biomarkers in the mCRC setting. Patient-specific level of concordance can readily be measured to establish the utility of circulating cells as biomarkers and define biosignatures for liquid biopsy assays. |
format | Online Article Text |
id | pubmed-6925029 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Impact Journals LLC |
record_format | MEDLINE/PubMed |
spelling | pubmed-69250292020-01-03 Single cell correlation analysis of liquid and solid biopsies in metastatic colorectal cancer Gerdtsson, Anna S. Thiele, Jana-Aletta Shishido, Stephanie N. Zheng, Serena Schaffer, Randolph Bethel, Kelly Curley, Steven Lenz, Heinz-Josef Hanna, Diana L. Nieva, Jorge Kolatkar, Anand Ruiz, Carmen Rodriguez-Lee, Mariam Oakley III, Gerard J. Lee, Jerry S.H. Hicks, James Kuhn, Peter Oncotarget Research Paper As cancer care is transitioning to personalized therapies with necessary complementary or companion biomarkers there is significant interest in determining to what extent non-invasive liquid biopsies reflect the gold standard solid biopsy. We have established an approach for measuring patient-specific circulating and solid cell concordance by introducing tumor touch preparations to the High-Definition Single Cell Analysis workflow for high-resolution cytomorphometric characterization of metastatic colorectal cancer (mCRC). Subgroups of cells based on size, shape and protein expression were identified in both liquid and solid biopsies, which overall displayed high inter- and intra- patient pleomorphism at the single-cell level of analysis. Concordance of liquid and solid biopsies was patient-dependent and between 0.1-0.9. Morphometric variables displayed particularly high correlation, suggesting that circulating cells do not represent distinct subpopulations from the solid tumor. This was further substantiated by significant decrease in concentration of circulating cells after mCRC resection. Combined with the association of circulating cells with tumor burden and necrosis of hepatic lesions, our overall findings demonstrate that liquid biopsy cells can be informative biomarkers in the mCRC setting. Patient-specific level of concordance can readily be measured to establish the utility of circulating cells as biomarkers and define biosignatures for liquid biopsy assays. Impact Journals LLC 2019-12-17 /pmc/articles/PMC6925029/ /pubmed/31903162 http://dx.doi.org/10.18632/oncotarget.27271 Text en Copyright: © 2019 Gerdtsson et al. http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/) 3.0 (CC BY 3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Paper Gerdtsson, Anna S. Thiele, Jana-Aletta Shishido, Stephanie N. Zheng, Serena Schaffer, Randolph Bethel, Kelly Curley, Steven Lenz, Heinz-Josef Hanna, Diana L. Nieva, Jorge Kolatkar, Anand Ruiz, Carmen Rodriguez-Lee, Mariam Oakley III, Gerard J. Lee, Jerry S.H. Hicks, James Kuhn, Peter Single cell correlation analysis of liquid and solid biopsies in metastatic colorectal cancer |
title | Single cell correlation analysis of liquid and solid biopsies in metastatic colorectal cancer |
title_full | Single cell correlation analysis of liquid and solid biopsies in metastatic colorectal cancer |
title_fullStr | Single cell correlation analysis of liquid and solid biopsies in metastatic colorectal cancer |
title_full_unstemmed | Single cell correlation analysis of liquid and solid biopsies in metastatic colorectal cancer |
title_short | Single cell correlation analysis of liquid and solid biopsies in metastatic colorectal cancer |
title_sort | single cell correlation analysis of liquid and solid biopsies in metastatic colorectal cancer |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6925029/ https://www.ncbi.nlm.nih.gov/pubmed/31903162 http://dx.doi.org/10.18632/oncotarget.27271 |
work_keys_str_mv | AT gerdtssonannas singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT thielejanaaletta singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT shishidostephanien singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT zhengserena singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT schafferrandolph singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT bethelkelly singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT curleysteven singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT lenzheinzjosef singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT hannadianal singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT nievajorge singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT kolatkaranand singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT ruizcarmen singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT rodriguezleemariam singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT oakleyiiigerardj singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT leejerrysh singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT hicksjames singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer AT kuhnpeter singlecellcorrelationanalysisofliquidandsolidbiopsiesinmetastaticcolorectalcancer |