Cargando…
A Preprocess Method of External Disturbance Suppression for Carotid Wall Motion Estimation Using Local Phase and Orientation of B-Mode Ultrasound Sequences
Estimating the motions of the common carotid artery wall plays a very important role in early diagnosis of the carotid atherosclerotic disease. However, the disturbances caused by either the instability of the probe operator or the breathing of subjects degrade the estimation accuracy of arterial wa...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6925731/ https://www.ncbi.nlm.nih.gov/pubmed/31886237 http://dx.doi.org/10.1155/2019/6547982 |
_version_ | 1783481962118250496 |
---|---|
author | Zhang, Qinghui Li, Junqiu Qiang, Zhenping He, Libo |
author_facet | Zhang, Qinghui Li, Junqiu Qiang, Zhenping He, Libo |
author_sort | Zhang, Qinghui |
collection | PubMed |
description | Estimating the motions of the common carotid artery wall plays a very important role in early diagnosis of the carotid atherosclerotic disease. However, the disturbances caused by either the instability of the probe operator or the breathing of subjects degrade the estimation accuracy of arterial wall motion when performing speckle tracking on the B-mode ultrasound images. In this paper, we propose a global registration method to suppress external disturbances before motion estimation. The local vector images, transformed from B-mode images, were used for registration. To take advantage of both the structural information from the local phase and the geometric information from the local orientation, we proposed a confidence coefficient to combine them two. Furthermore, we altered the speckle reducing anisotropic diffusion filter to improve the performance of disturbance suppression. We compared this method with schemes of extracting wall displacement directly from B-mode or phase images. The results show that this scheme can effectively suppress the disturbances and significantly improve the estimation accuracy. |
format | Online Article Text |
id | pubmed-6925731 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-69257312019-12-29 A Preprocess Method of External Disturbance Suppression for Carotid Wall Motion Estimation Using Local Phase and Orientation of B-Mode Ultrasound Sequences Zhang, Qinghui Li, Junqiu Qiang, Zhenping He, Libo Biomed Res Int Research Article Estimating the motions of the common carotid artery wall plays a very important role in early diagnosis of the carotid atherosclerotic disease. However, the disturbances caused by either the instability of the probe operator or the breathing of subjects degrade the estimation accuracy of arterial wall motion when performing speckle tracking on the B-mode ultrasound images. In this paper, we propose a global registration method to suppress external disturbances before motion estimation. The local vector images, transformed from B-mode images, were used for registration. To take advantage of both the structural information from the local phase and the geometric information from the local orientation, we proposed a confidence coefficient to combine them two. Furthermore, we altered the speckle reducing anisotropic diffusion filter to improve the performance of disturbance suppression. We compared this method with schemes of extracting wall displacement directly from B-mode or phase images. The results show that this scheme can effectively suppress the disturbances and significantly improve the estimation accuracy. Hindawi 2019-11-21 /pmc/articles/PMC6925731/ /pubmed/31886237 http://dx.doi.org/10.1155/2019/6547982 Text en Copyright © 2019 Qinghui Zhang et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhang, Qinghui Li, Junqiu Qiang, Zhenping He, Libo A Preprocess Method of External Disturbance Suppression for Carotid Wall Motion Estimation Using Local Phase and Orientation of B-Mode Ultrasound Sequences |
title | A Preprocess Method of External Disturbance Suppression for Carotid Wall Motion Estimation Using Local Phase and Orientation of B-Mode Ultrasound Sequences |
title_full | A Preprocess Method of External Disturbance Suppression for Carotid Wall Motion Estimation Using Local Phase and Orientation of B-Mode Ultrasound Sequences |
title_fullStr | A Preprocess Method of External Disturbance Suppression for Carotid Wall Motion Estimation Using Local Phase and Orientation of B-Mode Ultrasound Sequences |
title_full_unstemmed | A Preprocess Method of External Disturbance Suppression for Carotid Wall Motion Estimation Using Local Phase and Orientation of B-Mode Ultrasound Sequences |
title_short | A Preprocess Method of External Disturbance Suppression for Carotid Wall Motion Estimation Using Local Phase and Orientation of B-Mode Ultrasound Sequences |
title_sort | preprocess method of external disturbance suppression for carotid wall motion estimation using local phase and orientation of b-mode ultrasound sequences |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6925731/ https://www.ncbi.nlm.nih.gov/pubmed/31886237 http://dx.doi.org/10.1155/2019/6547982 |
work_keys_str_mv | AT zhangqinghui apreprocessmethodofexternaldisturbancesuppressionforcarotidwallmotionestimationusinglocalphaseandorientationofbmodeultrasoundsequences AT lijunqiu apreprocessmethodofexternaldisturbancesuppressionforcarotidwallmotionestimationusinglocalphaseandorientationofbmodeultrasoundsequences AT qiangzhenping apreprocessmethodofexternaldisturbancesuppressionforcarotidwallmotionestimationusinglocalphaseandorientationofbmodeultrasoundsequences AT helibo apreprocessmethodofexternaldisturbancesuppressionforcarotidwallmotionestimationusinglocalphaseandorientationofbmodeultrasoundsequences AT zhangqinghui preprocessmethodofexternaldisturbancesuppressionforcarotidwallmotionestimationusinglocalphaseandorientationofbmodeultrasoundsequences AT lijunqiu preprocessmethodofexternaldisturbancesuppressionforcarotidwallmotionestimationusinglocalphaseandorientationofbmodeultrasoundsequences AT qiangzhenping preprocessmethodofexternaldisturbancesuppressionforcarotidwallmotionestimationusinglocalphaseandorientationofbmodeultrasoundsequences AT helibo preprocessmethodofexternaldisturbancesuppressionforcarotidwallmotionestimationusinglocalphaseandorientationofbmodeultrasoundsequences |