Cargando…

Magnetic Resonance Imaging and Its Effects on Metallic Brackets and Wires: Does It Alter the Temperature and Bonding Efficacy of Orthodontic Devices?

Magnetic resonance imaging (MRI) is a widely used diagnostic technique. Patients wearing orthodontic appliances are often requested to remove their appliances, even when the MRI exam involves anatomical areas far from mouth, in order to avoid heating of the metal and detachment of the appliance. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Sfondrini, Maria Francesca, Preda, Lorenzo, Calliada, Fabrizio, Carbone, Lorenzo, Lungarotti, Luca, Bernardinelli, Luisa, Gandini, Paola, Scribante, Andrea
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6926903/
https://www.ncbi.nlm.nih.gov/pubmed/31801202
http://dx.doi.org/10.3390/ma12233971
_version_ 1783482201496616960
author Sfondrini, Maria Francesca
Preda, Lorenzo
Calliada, Fabrizio
Carbone, Lorenzo
Lungarotti, Luca
Bernardinelli, Luisa
Gandini, Paola
Scribante, Andrea
author_facet Sfondrini, Maria Francesca
Preda, Lorenzo
Calliada, Fabrizio
Carbone, Lorenzo
Lungarotti, Luca
Bernardinelli, Luisa
Gandini, Paola
Scribante, Andrea
author_sort Sfondrini, Maria Francesca
collection PubMed
description Magnetic resonance imaging (MRI) is a widely used diagnostic technique. Patients wearing orthodontic appliances are often requested to remove their appliances, even when the MRI exam involves anatomical areas far from mouth, in order to avoid heating of the metal and detachment of the appliance. The purpose of the present investigation was to measure and compare temperature changes and orthodontic appliances’ adhesion to enamel after different MRIs. A total of 220 orthodontic brackets were bonded on bovine incisors and wires with different materials (stainless steel and nickel titanium). Moreover, various sizes (0.014″ and 0.019″ × 0.025″) were engaged. Appliances were submitted to MRI at two different powers (1.5 T and 3 T). The temperatures of brackets and wires were measured before and after MRI. Subsequently, the shear bond strength (SBS) and adhesive remnant index (ARI) scores were recorded. Statistical analysis was performed. After MRI, a significant increase in the temperature was found for both the brackets and wires in some groups, even if the mean temperature increase was clinically insignificant, as the temperature ranged between 0.05 °C and 2.4 °C for brackets and between 0.42 °C and 1.74 °C for wires. The MRI did not condition bracket adhesion in any group. No differences were reported when comparing the 1.5 T with 3 T groups. The ARI Scores were also significantly lower after MRI. The results of the present report show that, under MRI, orthodontic appliances present a low temperature rise and no debonding risk. Therefore, the removal of orthodontic appliance is not recommended routinely, but is suggested only in the case of a void risk or potential interference in image quality.
format Online
Article
Text
id pubmed-6926903
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69269032019-12-23 Magnetic Resonance Imaging and Its Effects on Metallic Brackets and Wires: Does It Alter the Temperature and Bonding Efficacy of Orthodontic Devices? Sfondrini, Maria Francesca Preda, Lorenzo Calliada, Fabrizio Carbone, Lorenzo Lungarotti, Luca Bernardinelli, Luisa Gandini, Paola Scribante, Andrea Materials (Basel) Article Magnetic resonance imaging (MRI) is a widely used diagnostic technique. Patients wearing orthodontic appliances are often requested to remove their appliances, even when the MRI exam involves anatomical areas far from mouth, in order to avoid heating of the metal and detachment of the appliance. The purpose of the present investigation was to measure and compare temperature changes and orthodontic appliances’ adhesion to enamel after different MRIs. A total of 220 orthodontic brackets were bonded on bovine incisors and wires with different materials (stainless steel and nickel titanium). Moreover, various sizes (0.014″ and 0.019″ × 0.025″) were engaged. Appliances were submitted to MRI at two different powers (1.5 T and 3 T). The temperatures of brackets and wires were measured before and after MRI. Subsequently, the shear bond strength (SBS) and adhesive remnant index (ARI) scores were recorded. Statistical analysis was performed. After MRI, a significant increase in the temperature was found for both the brackets and wires in some groups, even if the mean temperature increase was clinically insignificant, as the temperature ranged between 0.05 °C and 2.4 °C for brackets and between 0.42 °C and 1.74 °C for wires. The MRI did not condition bracket adhesion in any group. No differences were reported when comparing the 1.5 T with 3 T groups. The ARI Scores were also significantly lower after MRI. The results of the present report show that, under MRI, orthodontic appliances present a low temperature rise and no debonding risk. Therefore, the removal of orthodontic appliance is not recommended routinely, but is suggested only in the case of a void risk or potential interference in image quality. MDPI 2019-11-30 /pmc/articles/PMC6926903/ /pubmed/31801202 http://dx.doi.org/10.3390/ma12233971 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sfondrini, Maria Francesca
Preda, Lorenzo
Calliada, Fabrizio
Carbone, Lorenzo
Lungarotti, Luca
Bernardinelli, Luisa
Gandini, Paola
Scribante, Andrea
Magnetic Resonance Imaging and Its Effects on Metallic Brackets and Wires: Does It Alter the Temperature and Bonding Efficacy of Orthodontic Devices?
title Magnetic Resonance Imaging and Its Effects on Metallic Brackets and Wires: Does It Alter the Temperature and Bonding Efficacy of Orthodontic Devices?
title_full Magnetic Resonance Imaging and Its Effects on Metallic Brackets and Wires: Does It Alter the Temperature and Bonding Efficacy of Orthodontic Devices?
title_fullStr Magnetic Resonance Imaging and Its Effects on Metallic Brackets and Wires: Does It Alter the Temperature and Bonding Efficacy of Orthodontic Devices?
title_full_unstemmed Magnetic Resonance Imaging and Its Effects on Metallic Brackets and Wires: Does It Alter the Temperature and Bonding Efficacy of Orthodontic Devices?
title_short Magnetic Resonance Imaging and Its Effects on Metallic Brackets and Wires: Does It Alter the Temperature and Bonding Efficacy of Orthodontic Devices?
title_sort magnetic resonance imaging and its effects on metallic brackets and wires: does it alter the temperature and bonding efficacy of orthodontic devices?
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6926903/
https://www.ncbi.nlm.nih.gov/pubmed/31801202
http://dx.doi.org/10.3390/ma12233971
work_keys_str_mv AT sfondrinimariafrancesca magneticresonanceimaginganditseffectsonmetallicbracketsandwiresdoesitalterthetemperatureandbondingefficacyoforthodonticdevices
AT predalorenzo magneticresonanceimaginganditseffectsonmetallicbracketsandwiresdoesitalterthetemperatureandbondingefficacyoforthodonticdevices
AT calliadafabrizio magneticresonanceimaginganditseffectsonmetallicbracketsandwiresdoesitalterthetemperatureandbondingefficacyoforthodonticdevices
AT carbonelorenzo magneticresonanceimaginganditseffectsonmetallicbracketsandwiresdoesitalterthetemperatureandbondingefficacyoforthodonticdevices
AT lungarottiluca magneticresonanceimaginganditseffectsonmetallicbracketsandwiresdoesitalterthetemperatureandbondingefficacyoforthodonticdevices
AT bernardinelliluisa magneticresonanceimaginganditseffectsonmetallicbracketsandwiresdoesitalterthetemperatureandbondingefficacyoforthodonticdevices
AT gandinipaola magneticresonanceimaginganditseffectsonmetallicbracketsandwiresdoesitalterthetemperatureandbondingefficacyoforthodonticdevices
AT scribanteandrea magneticresonanceimaginganditseffectsonmetallicbracketsandwiresdoesitalterthetemperatureandbondingefficacyoforthodonticdevices