Cargando…

Picosecond pump–probe X-ray scattering at the Elettra SAXS beamline

A new setup for picosecond pump–probe X-ray scattering at the Austrian SAXS beamline at Elettra-Sincrotrone Trieste is presented. A high-power/high-repetion-rate laser has been installed on-site, delivering UV/VIS/IR femto­second-pulses in-sync with the storage ring. Data acquisition is achieved by...

Descripción completa

Detalles Bibliográficos
Autores principales: Burian, Max, Marmiroli, Benedetta, Radeticchio, Andrea, Morello, Christian, Naumenko, Denys, Biasiol, Giorgio, Amenitsch, Heinz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6927520/
https://www.ncbi.nlm.nih.gov/pubmed/31868736
http://dx.doi.org/10.1107/S1600577519015728
_version_ 1783482315352047616
author Burian, Max
Marmiroli, Benedetta
Radeticchio, Andrea
Morello, Christian
Naumenko, Denys
Biasiol, Giorgio
Amenitsch, Heinz
author_facet Burian, Max
Marmiroli, Benedetta
Radeticchio, Andrea
Morello, Christian
Naumenko, Denys
Biasiol, Giorgio
Amenitsch, Heinz
author_sort Burian, Max
collection PubMed
description A new setup for picosecond pump–probe X-ray scattering at the Austrian SAXS beamline at Elettra-Sincrotrone Trieste is presented. A high-power/high-repetion-rate laser has been installed on-site, delivering UV/VIS/IR femto­second-pulses in-sync with the storage ring. Data acquisition is achieved by gating a multi-panel detector, capable of discriminating the single X-ray pulse in the dark-gap of the Elettra hybrid filling mode. Specific aspects of laser- and detection-synchronization, on-line beam steering as well protocols for spatial and temporal overlap of laser and X-ray beam are also described. The capabilities of the setup are demonstrated by studying transient heat-transfer in an In/Al/GaAs superlattice structure and results are confirmed by theoretical calculations.
format Online
Article
Text
id pubmed-6927520
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-69275202020-01-07 Picosecond pump–probe X-ray scattering at the Elettra SAXS beamline Burian, Max Marmiroli, Benedetta Radeticchio, Andrea Morello, Christian Naumenko, Denys Biasiol, Giorgio Amenitsch, Heinz J Synchrotron Radiat Research Papers A new setup for picosecond pump–probe X-ray scattering at the Austrian SAXS beamline at Elettra-Sincrotrone Trieste is presented. A high-power/high-repetion-rate laser has been installed on-site, delivering UV/VIS/IR femto­second-pulses in-sync with the storage ring. Data acquisition is achieved by gating a multi-panel detector, capable of discriminating the single X-ray pulse in the dark-gap of the Elettra hybrid filling mode. Specific aspects of laser- and detection-synchronization, on-line beam steering as well protocols for spatial and temporal overlap of laser and X-ray beam are also described. The capabilities of the setup are demonstrated by studying transient heat-transfer in an In/Al/GaAs superlattice structure and results are confirmed by theoretical calculations. International Union of Crystallography 2020-01-01 /pmc/articles/PMC6927520/ /pubmed/31868736 http://dx.doi.org/10.1107/S1600577519015728 Text en © Max Burian et al. 2020 http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.http://creativecommons.org/licenses/by/4.0/
spellingShingle Research Papers
Burian, Max
Marmiroli, Benedetta
Radeticchio, Andrea
Morello, Christian
Naumenko, Denys
Biasiol, Giorgio
Amenitsch, Heinz
Picosecond pump–probe X-ray scattering at the Elettra SAXS beamline
title Picosecond pump–probe X-ray scattering at the Elettra SAXS beamline
title_full Picosecond pump–probe X-ray scattering at the Elettra SAXS beamline
title_fullStr Picosecond pump–probe X-ray scattering at the Elettra SAXS beamline
title_full_unstemmed Picosecond pump–probe X-ray scattering at the Elettra SAXS beamline
title_short Picosecond pump–probe X-ray scattering at the Elettra SAXS beamline
title_sort picosecond pump–probe x-ray scattering at the elettra saxs beamline
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6927520/
https://www.ncbi.nlm.nih.gov/pubmed/31868736
http://dx.doi.org/10.1107/S1600577519015728
work_keys_str_mv AT burianmax picosecondpumpprobexrayscatteringattheelettrasaxsbeamline
AT marmirolibenedetta picosecondpumpprobexrayscatteringattheelettrasaxsbeamline
AT radeticchioandrea picosecondpumpprobexrayscatteringattheelettrasaxsbeamline
AT morellochristian picosecondpumpprobexrayscatteringattheelettrasaxsbeamline
AT naumenkodenys picosecondpumpprobexrayscatteringattheelettrasaxsbeamline
AT biasiolgiorgio picosecondpumpprobexrayscatteringattheelettrasaxsbeamline
AT amenitschheinz picosecondpumpprobexrayscatteringattheelettrasaxsbeamline