Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation

BACKGROUND: Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is associated with increased risk of stroke and congestive heart failure. Lead-I electrocardiogram (ECG) devices are handheld instruments that can detect AF at a single-time point. PURPOSE: To assess the diagnosti...

Descripción completa

Detalles Bibliográficos
Autores principales: Duarte, Rui, Stainthorpe, Angela, Mahon, James, Greenhalgh, Janette, Richardson, Marty, Nevitt, Sarah, Kotas, Eleanor, Boland, Angela, Thom, Howard, Marshall, Tom, Hall, Mark, Takwoingi, Yemisi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6927656/
https://www.ncbi.nlm.nih.gov/pubmed/31869370
http://dx.doi.org/10.1371/journal.pone.0226671
_version_ 1783482340155064320
author Duarte, Rui
Stainthorpe, Angela
Mahon, James
Greenhalgh, Janette
Richardson, Marty
Nevitt, Sarah
Kotas, Eleanor
Boland, Angela
Thom, Howard
Marshall, Tom
Hall, Mark
Takwoingi, Yemisi
author_facet Duarte, Rui
Stainthorpe, Angela
Mahon, James
Greenhalgh, Janette
Richardson, Marty
Nevitt, Sarah
Kotas, Eleanor
Boland, Angela
Thom, Howard
Marshall, Tom
Hall, Mark
Takwoingi, Yemisi
author_sort Duarte, Rui
collection PubMed
description BACKGROUND: Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is associated with increased risk of stroke and congestive heart failure. Lead-I electrocardiogram (ECG) devices are handheld instruments that can detect AF at a single-time point. PURPOSE: To assess the diagnostic test accuracy, clinical impact and cost effectiveness of single-time point lead-I ECG devices compared with manual pulse palpation (MPP) followed by a 12-lead ECG for the detection of AF in symptomatic primary care patients with an irregular pulse. METHODS: Electronic databases (MEDLINE, MEDLINE Epub Ahead of Print and MEDLINE In-Process, EMBASE, PubMed and Cochrane Databases of Systematic Reviews, Cochrane Central Database of Controlled Trials, Database of Abstracts of Reviews of Effects, Health Technology Assessment Database) were searched to March 2018. Two reviewers screened the search results, extracted data and assessed study quality. Summary estimates of diagnostic accuracy were calculated using bivariate models. Cost-effectiveness was evaluated using an economic model consisting of a decision tree and two cohort Markov models. RESULTS: Diagnostic accuracy The diagnostic accuracy (13 publications reporting on nine studies) and clinical impact (24 publications reporting on 19 studies) results are derived from an asymptomatic population (used as a proxy for people with signs or symptoms of AF). The summary sensitivity of lead-I ECG devices was 93.9% (95% confidence interval [CI]: 86.2% to 97.4%) and summary specificity was 96.5% (95% CI: 90.4% to 98.8%). Cost effectiveness The de novo economic model yielded incremental cost effectiveness ratios (ICERs) per quality adjusted life year (QALY) gained. The results of the pairwise analysis show that all lead-I ECG devices generate ICERs per QALY gained below the £20,000-£30,000 threshold. Kardia Mobile is the most cost effective option in a full incremental analysis. Lead-I ECG tests may identify more AF cases than the standard diagnostic pathway. This comes at a higher cost but with greater patient benefit in terms of mortality and quality of life. LIMITATIONS: No published data evaluating the diagnostic accuracy, clinical impact or cost effectiveness of lead-I ECG devices for the target population are available. CONCLUSIONS: The use of single-time point lead-I ECG devices in primary care for the detection of AF in people with signs or symptoms of AF and an irregular pulse appears to be a cost effective use of NHS resources compared with MPP followed by a 12-lead ECG, given the assumptions used in the base case model. REGISTRATION: The protocol for this review is registered on PROSPERO as CRD42018090375.
format Online
Article
Text
id pubmed-6927656
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-69276562020-01-07 Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation Duarte, Rui Stainthorpe, Angela Mahon, James Greenhalgh, Janette Richardson, Marty Nevitt, Sarah Kotas, Eleanor Boland, Angela Thom, Howard Marshall, Tom Hall, Mark Takwoingi, Yemisi PLoS One Research Article BACKGROUND: Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is associated with increased risk of stroke and congestive heart failure. Lead-I electrocardiogram (ECG) devices are handheld instruments that can detect AF at a single-time point. PURPOSE: To assess the diagnostic test accuracy, clinical impact and cost effectiveness of single-time point lead-I ECG devices compared with manual pulse palpation (MPP) followed by a 12-lead ECG for the detection of AF in symptomatic primary care patients with an irregular pulse. METHODS: Electronic databases (MEDLINE, MEDLINE Epub Ahead of Print and MEDLINE In-Process, EMBASE, PubMed and Cochrane Databases of Systematic Reviews, Cochrane Central Database of Controlled Trials, Database of Abstracts of Reviews of Effects, Health Technology Assessment Database) were searched to March 2018. Two reviewers screened the search results, extracted data and assessed study quality. Summary estimates of diagnostic accuracy were calculated using bivariate models. Cost-effectiveness was evaluated using an economic model consisting of a decision tree and two cohort Markov models. RESULTS: Diagnostic accuracy The diagnostic accuracy (13 publications reporting on nine studies) and clinical impact (24 publications reporting on 19 studies) results are derived from an asymptomatic population (used as a proxy for people with signs or symptoms of AF). The summary sensitivity of lead-I ECG devices was 93.9% (95% confidence interval [CI]: 86.2% to 97.4%) and summary specificity was 96.5% (95% CI: 90.4% to 98.8%). Cost effectiveness The de novo economic model yielded incremental cost effectiveness ratios (ICERs) per quality adjusted life year (QALY) gained. The results of the pairwise analysis show that all lead-I ECG devices generate ICERs per QALY gained below the £20,000-£30,000 threshold. Kardia Mobile is the most cost effective option in a full incremental analysis. Lead-I ECG tests may identify more AF cases than the standard diagnostic pathway. This comes at a higher cost but with greater patient benefit in terms of mortality and quality of life. LIMITATIONS: No published data evaluating the diagnostic accuracy, clinical impact or cost effectiveness of lead-I ECG devices for the target population are available. CONCLUSIONS: The use of single-time point lead-I ECG devices in primary care for the detection of AF in people with signs or symptoms of AF and an irregular pulse appears to be a cost effective use of NHS resources compared with MPP followed by a 12-lead ECG, given the assumptions used in the base case model. REGISTRATION: The protocol for this review is registered on PROSPERO as CRD42018090375. Public Library of Science 2019-12-23 /pmc/articles/PMC6927656/ /pubmed/31869370 http://dx.doi.org/10.1371/journal.pone.0226671 Text en © 2019 Duarte et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Duarte, Rui
Stainthorpe, Angela
Mahon, James
Greenhalgh, Janette
Richardson, Marty
Nevitt, Sarah
Kotas, Eleanor
Boland, Angela
Thom, Howard
Marshall, Tom
Hall, Mark
Takwoingi, Yemisi
Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation
title Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation
title_full Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation
title_fullStr Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation
title_full_unstemmed Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation
title_short Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation
title_sort lead-i ecg for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: a systematic review and economic evaluation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6927656/
https://www.ncbi.nlm.nih.gov/pubmed/31869370
http://dx.doi.org/10.1371/journal.pone.0226671
work_keys_str_mv AT duarterui leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT stainthorpeangela leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT mahonjames leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT greenhalghjanette leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT richardsonmarty leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT nevittsarah leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT kotaseleanor leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT bolandangela leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT thomhoward leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT marshalltom leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT hallmark leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT takwoingiyemisi leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation