Cargando…

Impact of screw length and screw quantity on reverse total shoulder arthroplasty glenoid fixation for 2 different sizes of glenoid baseplates

BACKGROUND: Little guidance exists regarding the minimum screw length and screw quantity necessary to achieve fixation in reverse total shoulder arthroplasty (rTSA); to that end, this study quantified the displacement of 2 different sizes of glenoid baseplates using multiple different screw lengths...

Descripción completa

Detalles Bibliográficos
Autores principales: Roche, Christopher, DiGeorgio, Caitlin, Yegres, Jose, VanDeven, Jennifer, Stroud, Nick, Flurin, Pierre-Henri, Wright, Thomas, Cheung, Emilie, Zuckerman, Joseph D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6928260/
https://www.ncbi.nlm.nih.gov/pubmed/31891029
http://dx.doi.org/10.1016/j.jses.2019.08.006
_version_ 1783482446355890176
author Roche, Christopher
DiGeorgio, Caitlin
Yegres, Jose
VanDeven, Jennifer
Stroud, Nick
Flurin, Pierre-Henri
Wright, Thomas
Cheung, Emilie
Zuckerman, Joseph D.
author_facet Roche, Christopher
DiGeorgio, Caitlin
Yegres, Jose
VanDeven, Jennifer
Stroud, Nick
Flurin, Pierre-Henri
Wright, Thomas
Cheung, Emilie
Zuckerman, Joseph D.
author_sort Roche, Christopher
collection PubMed
description BACKGROUND: Little guidance exists regarding the minimum screw length and screw quantity necessary to achieve fixation in reverse total shoulder arthroplasty (rTSA); to that end, this study quantified the displacement of 2 different sizes of glenoid baseplates using multiple different screw lengths and quantities of screws in a low-density polyurethane bone-substitute model. METHODS: Testing of rTSA glenoid loosening was conducted according to ASTM F 2028-17. To independently evaluate the impact of screw quantity and screw length on rTSA glenoid fixation for 2 different sizes of glenoid baseplates, baseplates were constructed using 2 screws, 4 screws, or 6 screws (with the latter being used for the larger baseplate only) with 3 different poly-axial locking compression screw lengths. RESULTS: Both sizes of glenoid baseplates remained well fixed after cyclic loading regardless of screw length or screw quantity. Baseplates with 2 screws had significantly greater displacement than baseplates with 4 or 6 screws. No differences were observed between baseplates with 4 screws and those with 6 screws (used for the larger baseplate). Both sizes of baseplates with 18-mm screws had significantly greater displacement than baseplates with 30- or 46-mm screws. For larger baseplates, those with 30-mm screws had significantly greater displacement than those with 46-mm screws in the superior-inferior direction. DISCUSSION: For the 2 different sizes of baseplates tested in this study, rTSA glenoid fixation was impacted by both screw quantity and screw length. Irrespective of screw quantity, longer screws showed significantly better fixation. Irrespective of screw length, the use of more screws showed significantly better fixation, up to a point, as the use of more than 4 screws showed no incremental benefit. Finally, longer screws can be used as a substitute for additional fixation if it is not feasible to use more screws.
format Online
Article
Text
id pubmed-6928260
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-69282602019-12-30 Impact of screw length and screw quantity on reverse total shoulder arthroplasty glenoid fixation for 2 different sizes of glenoid baseplates Roche, Christopher DiGeorgio, Caitlin Yegres, Jose VanDeven, Jennifer Stroud, Nick Flurin, Pierre-Henri Wright, Thomas Cheung, Emilie Zuckerman, Joseph D. JSES Open Access Article BACKGROUND: Little guidance exists regarding the minimum screw length and screw quantity necessary to achieve fixation in reverse total shoulder arthroplasty (rTSA); to that end, this study quantified the displacement of 2 different sizes of glenoid baseplates using multiple different screw lengths and quantities of screws in a low-density polyurethane bone-substitute model. METHODS: Testing of rTSA glenoid loosening was conducted according to ASTM F 2028-17. To independently evaluate the impact of screw quantity and screw length on rTSA glenoid fixation for 2 different sizes of glenoid baseplates, baseplates were constructed using 2 screws, 4 screws, or 6 screws (with the latter being used for the larger baseplate only) with 3 different poly-axial locking compression screw lengths. RESULTS: Both sizes of glenoid baseplates remained well fixed after cyclic loading regardless of screw length or screw quantity. Baseplates with 2 screws had significantly greater displacement than baseplates with 4 or 6 screws. No differences were observed between baseplates with 4 screws and those with 6 screws (used for the larger baseplate). Both sizes of baseplates with 18-mm screws had significantly greater displacement than baseplates with 30- or 46-mm screws. For larger baseplates, those with 30-mm screws had significantly greater displacement than those with 46-mm screws in the superior-inferior direction. DISCUSSION: For the 2 different sizes of baseplates tested in this study, rTSA glenoid fixation was impacted by both screw quantity and screw length. Irrespective of screw quantity, longer screws showed significantly better fixation. Irrespective of screw length, the use of more screws showed significantly better fixation, up to a point, as the use of more than 4 screws showed no incremental benefit. Finally, longer screws can be used as a substitute for additional fixation if it is not feasible to use more screws. Elsevier 2019-11-01 /pmc/articles/PMC6928260/ /pubmed/31891029 http://dx.doi.org/10.1016/j.jses.2019.08.006 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Roche, Christopher
DiGeorgio, Caitlin
Yegres, Jose
VanDeven, Jennifer
Stroud, Nick
Flurin, Pierre-Henri
Wright, Thomas
Cheung, Emilie
Zuckerman, Joseph D.
Impact of screw length and screw quantity on reverse total shoulder arthroplasty glenoid fixation for 2 different sizes of glenoid baseplates
title Impact of screw length and screw quantity on reverse total shoulder arthroplasty glenoid fixation for 2 different sizes of glenoid baseplates
title_full Impact of screw length and screw quantity on reverse total shoulder arthroplasty glenoid fixation for 2 different sizes of glenoid baseplates
title_fullStr Impact of screw length and screw quantity on reverse total shoulder arthroplasty glenoid fixation for 2 different sizes of glenoid baseplates
title_full_unstemmed Impact of screw length and screw quantity on reverse total shoulder arthroplasty glenoid fixation for 2 different sizes of glenoid baseplates
title_short Impact of screw length and screw quantity on reverse total shoulder arthroplasty glenoid fixation for 2 different sizes of glenoid baseplates
title_sort impact of screw length and screw quantity on reverse total shoulder arthroplasty glenoid fixation for 2 different sizes of glenoid baseplates
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6928260/
https://www.ncbi.nlm.nih.gov/pubmed/31891029
http://dx.doi.org/10.1016/j.jses.2019.08.006
work_keys_str_mv AT rochechristopher impactofscrewlengthandscrewquantityonreversetotalshoulderarthroplastyglenoidfixationfor2differentsizesofglenoidbaseplates
AT digeorgiocaitlin impactofscrewlengthandscrewquantityonreversetotalshoulderarthroplastyglenoidfixationfor2differentsizesofglenoidbaseplates
AT yegresjose impactofscrewlengthandscrewquantityonreversetotalshoulderarthroplastyglenoidfixationfor2differentsizesofglenoidbaseplates
AT vandevenjennifer impactofscrewlengthandscrewquantityonreversetotalshoulderarthroplastyglenoidfixationfor2differentsizesofglenoidbaseplates
AT stroudnick impactofscrewlengthandscrewquantityonreversetotalshoulderarthroplastyglenoidfixationfor2differentsizesofglenoidbaseplates
AT flurinpierrehenri impactofscrewlengthandscrewquantityonreversetotalshoulderarthroplastyglenoidfixationfor2differentsizesofglenoidbaseplates
AT wrightthomas impactofscrewlengthandscrewquantityonreversetotalshoulderarthroplastyglenoidfixationfor2differentsizesofglenoidbaseplates
AT cheungemilie impactofscrewlengthandscrewquantityonreversetotalshoulderarthroplastyglenoidfixationfor2differentsizesofglenoidbaseplates
AT zuckermanjosephd impactofscrewlengthandscrewquantityonreversetotalshoulderarthroplastyglenoidfixationfor2differentsizesofglenoidbaseplates