Cargando…

Validation of a Low-Cost Electromyography (EMG) System via a Commercial and Accurate EMG Device: Pilot Study

Electromyography (EMG) devices are well-suited for measuring the behaviour of muscles during an exercise or a task, and are widely used in many different research areas. Their disadvantage is that commercial systems are expensive. We designed a low-cost EMG system with enough accuracy and reliabilit...

Descripción completa

Detalles Bibliográficos
Autores principales: Fuentes del Toro, Sergio, Wei, Yuyang, Olmeda, Ester, Ren, Lei, Guowu, Wei, Díaz, Vicente
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6928739/
https://www.ncbi.nlm.nih.gov/pubmed/31795083
http://dx.doi.org/10.3390/s19235214
_version_ 1783482541914718208
author Fuentes del Toro, Sergio
Wei, Yuyang
Olmeda, Ester
Ren, Lei
Guowu, Wei
Díaz, Vicente
author_facet Fuentes del Toro, Sergio
Wei, Yuyang
Olmeda, Ester
Ren, Lei
Guowu, Wei
Díaz, Vicente
author_sort Fuentes del Toro, Sergio
collection PubMed
description Electromyography (EMG) devices are well-suited for measuring the behaviour of muscles during an exercise or a task, and are widely used in many different research areas. Their disadvantage is that commercial systems are expensive. We designed a low-cost EMG system with enough accuracy and reliability to be used in a wide range of possible ways. The present article focuses on the validation of the low-cost system we designed, which is compared with a commercially available, accurate device. The evaluation was done by means of a set of experiments, in which volunteers performed isometric and dynamic exercises while EMG signals from the rectus femoris muscle were registered by both the proposed low-cost system and a commercial system simultaneously. Analysis and assessment of three indicators to estimate the similarity between both signals were developed. These indicated a very good result, with spearman’s correlation averaging above 0.60, the energy ratio close to the 80% and the linear correlation coefficient approximating 100%. The agreement between both systems (custom and commercial) is excellent, although there are also some limitations, such as the delay of the signal (<1 s) and noise due to the hardware and assembly in the proposed system.
format Online
Article
Text
id pubmed-6928739
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69287392019-12-26 Validation of a Low-Cost Electromyography (EMG) System via a Commercial and Accurate EMG Device: Pilot Study Fuentes del Toro, Sergio Wei, Yuyang Olmeda, Ester Ren, Lei Guowu, Wei Díaz, Vicente Sensors (Basel) Article Electromyography (EMG) devices are well-suited for measuring the behaviour of muscles during an exercise or a task, and are widely used in many different research areas. Their disadvantage is that commercial systems are expensive. We designed a low-cost EMG system with enough accuracy and reliability to be used in a wide range of possible ways. The present article focuses on the validation of the low-cost system we designed, which is compared with a commercially available, accurate device. The evaluation was done by means of a set of experiments, in which volunteers performed isometric and dynamic exercises while EMG signals from the rectus femoris muscle were registered by both the proposed low-cost system and a commercial system simultaneously. Analysis and assessment of three indicators to estimate the similarity between both signals were developed. These indicated a very good result, with spearman’s correlation averaging above 0.60, the energy ratio close to the 80% and the linear correlation coefficient approximating 100%. The agreement between both systems (custom and commercial) is excellent, although there are also some limitations, such as the delay of the signal (<1 s) and noise due to the hardware and assembly in the proposed system. MDPI 2019-11-28 /pmc/articles/PMC6928739/ /pubmed/31795083 http://dx.doi.org/10.3390/s19235214 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Fuentes del Toro, Sergio
Wei, Yuyang
Olmeda, Ester
Ren, Lei
Guowu, Wei
Díaz, Vicente
Validation of a Low-Cost Electromyography (EMG) System via a Commercial and Accurate EMG Device: Pilot Study
title Validation of a Low-Cost Electromyography (EMG) System via a Commercial and Accurate EMG Device: Pilot Study
title_full Validation of a Low-Cost Electromyography (EMG) System via a Commercial and Accurate EMG Device: Pilot Study
title_fullStr Validation of a Low-Cost Electromyography (EMG) System via a Commercial and Accurate EMG Device: Pilot Study
title_full_unstemmed Validation of a Low-Cost Electromyography (EMG) System via a Commercial and Accurate EMG Device: Pilot Study
title_short Validation of a Low-Cost Electromyography (EMG) System via a Commercial and Accurate EMG Device: Pilot Study
title_sort validation of a low-cost electromyography (emg) system via a commercial and accurate emg device: pilot study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6928739/
https://www.ncbi.nlm.nih.gov/pubmed/31795083
http://dx.doi.org/10.3390/s19235214
work_keys_str_mv AT fuentesdeltorosergio validationofalowcostelectromyographyemgsystemviaacommercialandaccurateemgdevicepilotstudy
AT weiyuyang validationofalowcostelectromyographyemgsystemviaacommercialandaccurateemgdevicepilotstudy
AT olmedaester validationofalowcostelectromyographyemgsystemviaacommercialandaccurateemgdevicepilotstudy
AT renlei validationofalowcostelectromyographyemgsystemviaacommercialandaccurateemgdevicepilotstudy
AT guowuwei validationofalowcostelectromyographyemgsystemviaacommercialandaccurateemgdevicepilotstudy
AT diazvicente validationofalowcostelectromyographyemgsystemviaacommercialandaccurateemgdevicepilotstudy