Cargando…

Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays

Currently, phased arrays have found wide application in ultrasonic nondestructive testing. Volumetric results provided by the inspections with linear phased arrays have low lateral resolution in the elevation direction of such probes. This fact complicates the defects characterization task. In this...

Descripción completa

Detalles Bibliográficos
Autores principales: Dolmatov, Dmitry O., Tarrazó-Serrano, Daniel, Filippov, German A., Minin, Igor V., Minin, Oleg V., Sednev, Dmitry A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6928752/
https://www.ncbi.nlm.nih.gov/pubmed/31766335
http://dx.doi.org/10.3390/s19235080
_version_ 1783482544976560128
author Dolmatov, Dmitry O.
Tarrazó-Serrano, Daniel
Filippov, German A.
Minin, Igor V.
Minin, Oleg V.
Sednev, Dmitry A.
author_facet Dolmatov, Dmitry O.
Tarrazó-Serrano, Daniel
Filippov, German A.
Minin, Igor V.
Minin, Oleg V.
Sednev, Dmitry A.
author_sort Dolmatov, Dmitry O.
collection PubMed
description Currently, phased arrays have found wide application in ultrasonic nondestructive testing. Volumetric results provided by the inspections with linear phased arrays have low lateral resolution in the elevation direction of such probes. This fact complicates the defects characterization task. In this paper, we suggest the application of the Phase-Reversal Fresnel Zone Plate to increase the resolution of volumetric imaging with linear phased arrays. Application of such plates is aimed at ultrasonic focusing in the elevation plane whereas focusing on the active aperture plane is provided by the application of the Sampling Phased Array. Furthermore, the use of the Phase-Reversal Fresnel Zone Plate is advantageous due to the capability of its 3D printing and introduction to the existing automated testing systems avoiding making changes to the current software and hardware. The effectiveness of the plates was verified experimentally on the existing automated testing system. The obtained experimental results demonstrate that the application of the Phase-Reversal Fresnel Zone Plate allowed achieving the results of the higher resolution as well as improving the signal to noise ratio.
format Online
Article
Text
id pubmed-6928752
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69287522019-12-26 Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays Dolmatov, Dmitry O. Tarrazó-Serrano, Daniel Filippov, German A. Minin, Igor V. Minin, Oleg V. Sednev, Dmitry A. Sensors (Basel) Article Currently, phased arrays have found wide application in ultrasonic nondestructive testing. Volumetric results provided by the inspections with linear phased arrays have low lateral resolution in the elevation direction of such probes. This fact complicates the defects characterization task. In this paper, we suggest the application of the Phase-Reversal Fresnel Zone Plate to increase the resolution of volumetric imaging with linear phased arrays. Application of such plates is aimed at ultrasonic focusing in the elevation plane whereas focusing on the active aperture plane is provided by the application of the Sampling Phased Array. Furthermore, the use of the Phase-Reversal Fresnel Zone Plate is advantageous due to the capability of its 3D printing and introduction to the existing automated testing systems avoiding making changes to the current software and hardware. The effectiveness of the plates was verified experimentally on the existing automated testing system. The obtained experimental results demonstrate that the application of the Phase-Reversal Fresnel Zone Plate allowed achieving the results of the higher resolution as well as improving the signal to noise ratio. MDPI 2019-11-21 /pmc/articles/PMC6928752/ /pubmed/31766335 http://dx.doi.org/10.3390/s19235080 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dolmatov, Dmitry O.
Tarrazó-Serrano, Daniel
Filippov, German A.
Minin, Igor V.
Minin, Oleg V.
Sednev, Dmitry A.
Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays
title Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays
title_full Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays
title_fullStr Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays
title_full_unstemmed Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays
title_short Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays
title_sort application of phase-reversal fresnel zone plates for improving the elevation resolution in ultrasonic testing with phased arrays
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6928752/
https://www.ncbi.nlm.nih.gov/pubmed/31766335
http://dx.doi.org/10.3390/s19235080
work_keys_str_mv AT dolmatovdmitryo applicationofphasereversalfresnelzoneplatesforimprovingtheelevationresolutioninultrasonictestingwithphasedarrays
AT tarrazoserranodaniel applicationofphasereversalfresnelzoneplatesforimprovingtheelevationresolutioninultrasonictestingwithphasedarrays
AT filippovgermana applicationofphasereversalfresnelzoneplatesforimprovingtheelevationresolutioninultrasonictestingwithphasedarrays
AT mininigorv applicationofphasereversalfresnelzoneplatesforimprovingtheelevationresolutioninultrasonictestingwithphasedarrays
AT mininolegv applicationofphasereversalfresnelzoneplatesforimprovingtheelevationresolutioninultrasonictestingwithphasedarrays
AT sednevdmitrya applicationofphasereversalfresnelzoneplatesforimprovingtheelevationresolutioninultrasonictestingwithphasedarrays