Cargando…

A New Model of RGB-D Camera Calibration Based on 3D Control Field

With extensive application of RGB-D cameras in robotics, computer vision, and many other fields, accurate calibration becomes more and more critical to the sensors. However, most existing models for calibrating depth and the relative pose between a depth camera and an RGB camera are not universally...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Chenyang, Huang, Teng, Zhao, Qiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6929019/
https://www.ncbi.nlm.nih.gov/pubmed/31766347
http://dx.doi.org/10.3390/s19235082
_version_ 1783482607556624384
author Zhang, Chenyang
Huang, Teng
Zhao, Qiang
author_facet Zhang, Chenyang
Huang, Teng
Zhao, Qiang
author_sort Zhang, Chenyang
collection PubMed
description With extensive application of RGB-D cameras in robotics, computer vision, and many other fields, accurate calibration becomes more and more critical to the sensors. However, most existing models for calibrating depth and the relative pose between a depth camera and an RGB camera are not universally applicable to many different kinds of RGB-D cameras. In this paper, by using the collinear equation and space resection of photogrammetry, we present a new model to correct the depth and calibrate the relative pose between depth and RGB cameras based on a 3D control field. We establish a rigorous relationship model between the two cameras; then, we optimize the relative parameters of two cameras by least-squares iteration. For depth correction, based on the extrinsic parameters related to object space, the reference depths are calculated by using a collinear equation. Then, we calibrate the depth measurements with consideration of the distortion of pixels in depth images. We apply Kinect-2 to verify the calibration parameters by registering depth and color images. We test the effect of depth correction based on 3D reconstruction. Compared to the registration results from a state-of-the-art calibration model, the registration results obtained with our calibration parameters improve dramatically. Likewise, the performances of 3D reconstruction demonstrate obvious improvements after depth correction.
format Online
Article
Text
id pubmed-6929019
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69290192019-12-26 A New Model of RGB-D Camera Calibration Based on 3D Control Field Zhang, Chenyang Huang, Teng Zhao, Qiang Sensors (Basel) Article With extensive application of RGB-D cameras in robotics, computer vision, and many other fields, accurate calibration becomes more and more critical to the sensors. However, most existing models for calibrating depth and the relative pose between a depth camera and an RGB camera are not universally applicable to many different kinds of RGB-D cameras. In this paper, by using the collinear equation and space resection of photogrammetry, we present a new model to correct the depth and calibrate the relative pose between depth and RGB cameras based on a 3D control field. We establish a rigorous relationship model between the two cameras; then, we optimize the relative parameters of two cameras by least-squares iteration. For depth correction, based on the extrinsic parameters related to object space, the reference depths are calculated by using a collinear equation. Then, we calibrate the depth measurements with consideration of the distortion of pixels in depth images. We apply Kinect-2 to verify the calibration parameters by registering depth and color images. We test the effect of depth correction based on 3D reconstruction. Compared to the registration results from a state-of-the-art calibration model, the registration results obtained with our calibration parameters improve dramatically. Likewise, the performances of 3D reconstruction demonstrate obvious improvements after depth correction. MDPI 2019-11-21 /pmc/articles/PMC6929019/ /pubmed/31766347 http://dx.doi.org/10.3390/s19235082 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhang, Chenyang
Huang, Teng
Zhao, Qiang
A New Model of RGB-D Camera Calibration Based on 3D Control Field
title A New Model of RGB-D Camera Calibration Based on 3D Control Field
title_full A New Model of RGB-D Camera Calibration Based on 3D Control Field
title_fullStr A New Model of RGB-D Camera Calibration Based on 3D Control Field
title_full_unstemmed A New Model of RGB-D Camera Calibration Based on 3D Control Field
title_short A New Model of RGB-D Camera Calibration Based on 3D Control Field
title_sort new model of rgb-d camera calibration based on 3d control field
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6929019/
https://www.ncbi.nlm.nih.gov/pubmed/31766347
http://dx.doi.org/10.3390/s19235082
work_keys_str_mv AT zhangchenyang anewmodelofrgbdcameracalibrationbasedon3dcontrolfield
AT huangteng anewmodelofrgbdcameracalibrationbasedon3dcontrolfield
AT zhaoqiang anewmodelofrgbdcameracalibrationbasedon3dcontrolfield
AT zhangchenyang newmodelofrgbdcameracalibrationbasedon3dcontrolfield
AT huangteng newmodelofrgbdcameracalibrationbasedon3dcontrolfield
AT zhaoqiang newmodelofrgbdcameracalibrationbasedon3dcontrolfield