Cargando…

A Clamping Force Estimation Method Based on a Joint Torque Disturbance Observer Using PSO-BPNN for Cable-Driven Surgical Robot End-Effectors

The ability to sense external force is an important technique for force feedback, haptics and safe interaction control in minimally-invasive surgical robots (MISRs). Moreover, this ability plays a significant role in the restricting refined surgical operations. The wrist joints of surgical robot end...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Zhengyu, Wang, Daoming, Chen, Bing, Yu, Lingtao, Qian, Jun, Zi, Bin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6929025/
https://www.ncbi.nlm.nih.gov/pubmed/31805636
http://dx.doi.org/10.3390/s19235291
_version_ 1783482608945987584
author Wang, Zhengyu
Wang, Daoming
Chen, Bing
Yu, Lingtao
Qian, Jun
Zi, Bin
author_facet Wang, Zhengyu
Wang, Daoming
Chen, Bing
Yu, Lingtao
Qian, Jun
Zi, Bin
author_sort Wang, Zhengyu
collection PubMed
description The ability to sense external force is an important technique for force feedback, haptics and safe interaction control in minimally-invasive surgical robots (MISRs). Moreover, this ability plays a significant role in the restricting refined surgical operations. The wrist joints of surgical robot end-effectors are usually actuated by several long-distance wire cables. Its two forceps are each actuated by two cables. The scope of force sensing includes multidimensional external force and one-dimensional clamping force. This paper focuses on one-dimensional clamping force sensing method that do not require any internal force sensor integrated in the end-effector’s forceps. A new clamping force estimation method is proposed based on a joint torque disturbance observer (JTDO) for a cable-driven surgical robot end-effector. The JTDO essentially considers the variations in cable tension between the actual cable tension and the estimated cable tension using a Particle Swarm Optimization Back Propagation Neural Network (PSO-BPNN) under free motion. Furthermore, a clamping force estimator is proposed based on the forceps’ JTDO and their mechanical relations. According to comparative analyses in experimental studies, the detection resolutions of collision force and clamping force were 0.11 N. The experimental results verify the feasibility and effectiveness of the proposed clamping force sensing method.
format Online
Article
Text
id pubmed-6929025
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69290252019-12-26 A Clamping Force Estimation Method Based on a Joint Torque Disturbance Observer Using PSO-BPNN for Cable-Driven Surgical Robot End-Effectors Wang, Zhengyu Wang, Daoming Chen, Bing Yu, Lingtao Qian, Jun Zi, Bin Sensors (Basel) Article The ability to sense external force is an important technique for force feedback, haptics and safe interaction control in minimally-invasive surgical robots (MISRs). Moreover, this ability plays a significant role in the restricting refined surgical operations. The wrist joints of surgical robot end-effectors are usually actuated by several long-distance wire cables. Its two forceps are each actuated by two cables. The scope of force sensing includes multidimensional external force and one-dimensional clamping force. This paper focuses on one-dimensional clamping force sensing method that do not require any internal force sensor integrated in the end-effector’s forceps. A new clamping force estimation method is proposed based on a joint torque disturbance observer (JTDO) for a cable-driven surgical robot end-effector. The JTDO essentially considers the variations in cable tension between the actual cable tension and the estimated cable tension using a Particle Swarm Optimization Back Propagation Neural Network (PSO-BPNN) under free motion. Furthermore, a clamping force estimator is proposed based on the forceps’ JTDO and their mechanical relations. According to comparative analyses in experimental studies, the detection resolutions of collision force and clamping force were 0.11 N. The experimental results verify the feasibility and effectiveness of the proposed clamping force sensing method. MDPI 2019-12-01 /pmc/articles/PMC6929025/ /pubmed/31805636 http://dx.doi.org/10.3390/s19235291 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Zhengyu
Wang, Daoming
Chen, Bing
Yu, Lingtao
Qian, Jun
Zi, Bin
A Clamping Force Estimation Method Based on a Joint Torque Disturbance Observer Using PSO-BPNN for Cable-Driven Surgical Robot End-Effectors
title A Clamping Force Estimation Method Based on a Joint Torque Disturbance Observer Using PSO-BPNN for Cable-Driven Surgical Robot End-Effectors
title_full A Clamping Force Estimation Method Based on a Joint Torque Disturbance Observer Using PSO-BPNN for Cable-Driven Surgical Robot End-Effectors
title_fullStr A Clamping Force Estimation Method Based on a Joint Torque Disturbance Observer Using PSO-BPNN for Cable-Driven Surgical Robot End-Effectors
title_full_unstemmed A Clamping Force Estimation Method Based on a Joint Torque Disturbance Observer Using PSO-BPNN for Cable-Driven Surgical Robot End-Effectors
title_short A Clamping Force Estimation Method Based on a Joint Torque Disturbance Observer Using PSO-BPNN for Cable-Driven Surgical Robot End-Effectors
title_sort clamping force estimation method based on a joint torque disturbance observer using pso-bpnn for cable-driven surgical robot end-effectors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6929025/
https://www.ncbi.nlm.nih.gov/pubmed/31805636
http://dx.doi.org/10.3390/s19235291
work_keys_str_mv AT wangzhengyu aclampingforceestimationmethodbasedonajointtorquedisturbanceobserverusingpsobpnnforcabledrivensurgicalrobotendeffectors
AT wangdaoming aclampingforceestimationmethodbasedonajointtorquedisturbanceobserverusingpsobpnnforcabledrivensurgicalrobotendeffectors
AT chenbing aclampingforceestimationmethodbasedonajointtorquedisturbanceobserverusingpsobpnnforcabledrivensurgicalrobotendeffectors
AT yulingtao aclampingforceestimationmethodbasedonajointtorquedisturbanceobserverusingpsobpnnforcabledrivensurgicalrobotendeffectors
AT qianjun aclampingforceestimationmethodbasedonajointtorquedisturbanceobserverusingpsobpnnforcabledrivensurgicalrobotendeffectors
AT zibin aclampingforceestimationmethodbasedonajointtorquedisturbanceobserverusingpsobpnnforcabledrivensurgicalrobotendeffectors
AT wangzhengyu clampingforceestimationmethodbasedonajointtorquedisturbanceobserverusingpsobpnnforcabledrivensurgicalrobotendeffectors
AT wangdaoming clampingforceestimationmethodbasedonajointtorquedisturbanceobserverusingpsobpnnforcabledrivensurgicalrobotendeffectors
AT chenbing clampingforceestimationmethodbasedonajointtorquedisturbanceobserverusingpsobpnnforcabledrivensurgicalrobotendeffectors
AT yulingtao clampingforceestimationmethodbasedonajointtorquedisturbanceobserverusingpsobpnnforcabledrivensurgicalrobotendeffectors
AT qianjun clampingforceestimationmethodbasedonajointtorquedisturbanceobserverusingpsobpnnforcabledrivensurgicalrobotendeffectors
AT zibin clampingforceestimationmethodbasedonajointtorquedisturbanceobserverusingpsobpnnforcabledrivensurgicalrobotendeffectors